Systematic review including re-analyses of 1148 individual data sets of central venous pressure as a predictor of fluid responsiveness

被引:144
作者
Eskesen, T. G. [1 ]
Wetterslev, M. [1 ]
Perner, A. [1 ]
机构
[1] Copenhagen Univ Hosp, Dept Intens Care, Rigshosp, DK-2100 Copenhagen, Denmark
关键词
Central venous pressure; Critical illness; Fluid therapy; Haemodynamics; Intensive care; STROKE VOLUME VARIATION; CRITICALLY-ILL PATIENTS; FUNCTIONAL HEMODYNAMIC PARAMETERS; MECHANICALLY VENTILATED PATIENTS; CORRECTED FLOW TIME; CARDIAC-SURGERY; INTENSIVE-CARE; SEPTIC SHOCK; DIAGNOSTIC-ACCURACY; VARIABILITY INDEX;
D O I
10.1007/s00134-015-4168-4
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Central venous pressure (CVP) has been shown to have poor predictive value for fluid responsiveness in critically ill patients. We aimed to re-evaluate this in a larger sample subgrouped by baseline CVP values. In April 2015, we systematically searched and included all clinical studies evaluating the value of CVP in predicting fluid responsiveness. We contacted investigators for patient data sets. We subgrouped data as lower (< 8 mmHg), intermediate (8-12 mmHg) and higher (> 12 mmHg) baseline CVP. We included 51 studies; in the majority, mean/median CVP values were in the intermediate range (8-12 mmHg) in both fluid responders and non-responders. In an analysis of patient data sets (n = 1148) from 22 studies, the area under the receiver operating curve was above 0.50 in the < 8 mmHg CVP group [0.57 (95 % CI 0.52-0.62)] in contrast to the 8-12 mmHg and > 12 mmHg CVP groups in which the lower 95 % CI crossed 0.50. We identified some positive and negative predictive value for fluid responsiveness for specific low and high values of CVP, respectively, but none of the predictive values were above 66 % for any CVPs from 0 to 20 mmHg. There were less data on higher CVPs, in particular > 15 mmHg, making the estimates on predictive values less precise for higher CVP. Most studies evaluating fluid responsiveness reported mean/median CVP values in the intermediate range of 8-12 mmHg both in responders and non-responders. In a re-analysis of 1148 patient data sets, specific lower and higher CVP values had some positive and negative predictive value for fluid responsiveness, respectively, but predictive values were low for all specific CVP values assessed.
引用
收藏
页码:324 / 332
页数:9
相关论文
共 67 条
[51]   Understanding hypovolaemia [J].
Perner, Anders ;
De Backer, Daniel .
INTENSIVE CARE MEDICINE, 2014, 40 (04) :613-615
[52]   Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators [J].
Preisman, S ;
Kogan, S ;
Berkenstadt, H ;
Perel, A .
BRITISH JOURNAL OF ANAESTHESIA, 2005, 95 (06) :746-755
[53]   Early goal-directed therapy in the treatment of severe sepsis and septic shock. [J].
Rivers, E ;
Nguyen, B ;
Havstad, S ;
Ressler, J ;
Muzzin, A ;
Knoblich, B ;
Peterson, E ;
Tomlanovich, M .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (19) :1368-1377
[54]   Hemodynamic Pressure Waveform Analysis in Predicting Fluid Responsiveness [J].
Roy, Sebastien ;
Couture, Pierre ;
Qizilbash, Baqir ;
Toupin, Francis ;
Levesque, Sylvie ;
Carrier, Michel ;
Lambert, Jean ;
Denault, Andre Y. .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (04) :676-680
[55]   Prediction of fluid responsiveness in patients admitted to the medical intensive care unit [J].
Saugel, Bernd ;
Kirsche, Stephanie V. ;
Hapfelmeier, Alexander ;
Phillip, Veit ;
Schultheiss, Caroline ;
Schmid, Roland M. ;
Huber, Wolfgang .
JOURNAL OF CRITICAL CARE, 2013, 28 (04) :537.e1-537.e9
[56]   Utility of Uncalibrated Femoral Stroke Volume Variation as a Predictor of Fluid Responsiveness During the Anhepatic Phase of Liver Transplantation [J].
Shin, Young Hee ;
Ko, Justin Sangwook ;
Gwak, Mi Sook ;
Kim, Gaab Soo ;
Lee, Jong Hwan ;
Lee, Suk-Koo .
LIVER TRANSPLANTATION, 2011, 17 (01) :53-59
[57]   Central venous pressure: we need to bring clinical use into physiological context [J].
Sondergaard, S. ;
Parkin, G. ;
Aneman, A. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2015, 59 (05) :552-560
[58]   A comparison of transcutaneous Doppler corrected flow time, b-type natriuretic peptide and central venous pressure as predictors of fluid responsiveness in septic shock: a preliminary evaluation. [J].
Sturgess, D. J. ;
Pascoe, R. L. S. ;
Scalia, G. ;
Venkatesh, B. .
ANAESTHESIA AND INTENSIVE CARE, 2010, 38 (02) :336-341
[59]   Non-invasive stroke volume measurement and passive leg raising predict volume responsiveness in medical ICU patients: an observational cohort study [J].
Thiel, Steven W. ;
Kollef, Marin H. ;
Isakow, Warren .
CRITICAL CARE, 2009, 13 (04)
[60]   Global end-diastolic volume increases to maintain fluid responsiveness in sepsis-induced systolic dysfunction [J].
Trof, Ronald J. ;
Danad, Ibrahim ;
Groeneveld, A. B. Johan .
BMC ANESTHESIOLOGY, 2013, 13