Use of an integrated MS-multiplexed MS/MS data acquisition strategy for high-coverage peptide mapping studies

被引:61
作者
Chakraborty, Asish B. [1 ]
Berger, Scott J. [1 ]
Gebler, John C. [1 ]
机构
[1] Waters Corp, Life Sci R&D, Milford, MA 01757 USA
关键词
D O I
10.1002/rcm.2888
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography/mass spectrometry (LC/MS) peptide maps have become a basic tool for characterizing proteins of biological and pharmaceutical interest. The ability to generate reproducible maps with high protein sequence coverage is a central goal of methods development. We have applied a recently developed analytical approach (termed LC/MSE) to LC/MS peptide mapping. Using the LC/MSE approach, the mass detector alternates between a low-energy scanning mode (MS) for accurate mass peptide precursor identification, and an elevated-energy mode (MSE) for generation of accurate mass multiplex peptide fragmentation data. In this paper, we evaluate this analytical approach against a tryptic digest of yeast enolase. From the low-energy data, high peptide map coverage (98% of sequence from peptides > 3 amino acids) was reproducibly obtained. The MS signal for essentially equimolar peptides varied over 2 orders of magnitude in intensity, and peptide intensities could be precisely and reproducibly measured. Using the temporal constraint that MSE peptide fragment ions exhibit chromatographic profiles that parallel the precursor ions that generated them, we were able to produce accurate mass time-resolved MS/MS information for all enolase peptides with sufficient abundance to produce a detectable fragment ion. Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:730 / 744
页数:15
相关论文
共 38 条
  • [1] The human plasma proteome - A nonredundant list developed by combination of four separate sources
    Anderson, NL
    Polanski, M
    Pieper, R
    Gatlin, T
    Tirumalai, RS
    Conrads, TP
    Veenstra, TD
    Adkins, JN
    Pounds, JG
    Fagan, R
    Lobley, A
    [J]. MOLECULAR & CELLULAR PROTEOMICS, 2004, 3 (04) : 311 - 326
  • [2] A novel precursor ion discovery method on a hybrid quadrupole orthogonal acceleration time-of-flight (Q-TOF) mass spectrometer for studying protein phosphorylation
    Bateman, RH
    Carruthers, R
    Hoyes, JB
    Jones, C
    Langridge, JI
    Millar, A
    Vissers, JPC
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (07) : 792 - 803
  • [3] BATEMAN RH, 2001, Patent No. 6717130
  • [4] High-throughput global peptide proteomic analysis by combining stable isotope amino acid labeling and data-dependent multiplexed-MS/MS
    Berger, SJ
    Lee, SW
    Anderson, GA
    Pasa-Tolic, L
    Tolic, N
    Shen, YF
    Zhao, R
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (19) : 4994 - 5000
  • [5] Practical implications of some recent studies in electrospray ionization fundamentals
    Cech, NB
    Enke, CG
    [J]. MASS SPECTROMETRY REVIEWS, 2001, 20 (06) : 362 - 387
  • [6] Predicting electrospray response from chromatographic retention time
    Cech, NB
    Krone, JR
    Enke, CG
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (02) : 208 - 213
  • [7] Effect of affinity for droplet surfaces on the fraction of analyte molecules charged during electrospray droplet fission
    Cech, NB
    Enke, CG
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (19) : 4632 - 4639
  • [8] Role of accurate mass measurement (±10 ppm) in protein identification strategies employing MS or MS MS and database searching
    Clauser, KR
    Baker, P
    Burlingame, AL
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (14) : 2871 - 2882
  • [9] THE DETERMINATION OF GLYCOPEPTIDES BY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY WITH COLLISION-INDUCED DISSOCIATION
    CONBOY, JJ
    HENION, JD
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (08) : 804 - 814
  • [10] Utility of accurate mass tags for proteome-wide protein identification
    Conrads, TP
    Anderson, GA
    Veenstra, TD
    Pasa-Tolic, L
    Smith, RD
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (14) : 3349 - 3354