Validity of inertial measurement unit-based knee flexion strength-power test

被引:2
|
作者
Nagahara, Ryu [1 ]
Kameda, Mai [1 ]
Neville, Jonathon [2 ]
机构
[1] Natl Inst Fitness & Sports Kanoya, 1 Shiromizu Cho, Kanoya, Kagoshima 8912393, Japan
[2] Auckland Univ Technol, Sports Performance Res Inst New Zealand, Auckland, New Zealand
关键词
Joint torque; leg; accelerometer; gyroscope; fitness test; inertial measurement unit; RELIABILITY; PREDICTORS; LEG;
D O I
10.1177/1754337119845601
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This study aimed to examine the concurrent validity of inertial measurement unit-based knee flexion strength-power test variables. Ten physically active males performed a knee flexion strength-power test, consisting of serial right knee flexion-extension motions. Two trials were performed, each at 50%, 75% and 100% effort. Lower-extremity motion during the trial was recorded using a motion capture system and an inertial measurement unit. For inertial measurement unit data, the measured length of each lower-extremity segment was used to estimate segment endpoint coordinates. Knee flexion kinetic variables were then computed using inverse dynamics analysis for both systems. The inertial measurement unit provided comparable values with the motion capture system for angular impulse, mean moment, positive work and mean power (-0.8%, 1.0%, -0.9%, and 1.5%, respectively). Moreover, intraclass correlation coefficients and correlation coefficients for angular impulse, mean moment, positive work and mean power of knee flexion were acceptably high (ICC or r = 0.903-0.970). For positive mean power, however, a Bland-Altman plot showed heteroscedasticity. For knee flexion negative work and mean power, the inertial measurement unit clearly showed an overestimation of the values (32.5% and 23.5%, respectively). Moreover, the intraclass correlation coefficients and correlation coefficients were not acceptably high for knee flexion negative work and mean power (ICC or r = 0.541-0.899). These results indicate that the angular impulse, mean moment and positive work can be measured accurately and validly using an inertial measurement unit for knee flexion strength-power test variables. Given its simplicity, the suggested inertial measurement unit-based knee flexion strength-power test would improve on-the-field physical fitness evaluation.
引用
收藏
页码:443 / 449
页数:7
相关论文
共 50 条
  • [1] Inertial measurement unit based knee flexion strength-power test for sprinters
    Nagahara, Ryu
    Murata, Munenori
    INTERNATIONAL JOURNAL OF SPORTS SCIENCE & COACHING, 2020, 15 (5-6) : 738 - 744
  • [2] Inertial Measurement Unit Based Hip Flexion Strength-Power Test for Sprinters
    Nagahara, Ryu
    Murata, Munenori
    FRONTIERS IN SPORTS AND ACTIVE LIVING, 2020, 2
  • [3] Inertial measurement unit-based hip flexion test as an indicator of sprint performance
    Nagahara, Ryu
    Kameda, Mai
    Neville, Jonathon
    Morin, Jean-Benoit
    JOURNAL OF SPORTS SCIENCES, 2020, 38 (01) : 53 - 61
  • [4] Evaluation of Validity and Reliability of Inertial Measurement Unit-Based Gait Analysis Systems
    Cho, Young-Shin
    Jang, Seong-Ho
    Cho, Jae-Sung
    Kim, Mi-Jung
    Lee, Hyeok Dong
    Lee, Sung Young
    Moon, Sang-Bok
    ANNALS OF REHABILITATION MEDICINE-ARM, 2018, 42 (06): : 872 - 883
  • [5] Reliability and validity of estimated angles information assessed using inertial measurement unit-based motion sensors
    Morikawa, Taiki
    Mura, Nariyuki
    Sato, Toshiaki
    Katoh, Hiroshi
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2024, 35 (05) : 439 - 450
  • [6] Inertial Measurement Unit-Based Estimation of Foot Trajectory for Clinical Gait Analysis
    Hori, Koyu
    Mao, Yufeng
    Ono, Yumi
    Ora, Hiroki
    Hirobe, Yuki
    Sawada, Hiroyuki
    Inaba, Akira
    Orimo, Satoshi
    Miyake, Yoshihiro
    FRONTIERS IN PHYSIOLOGY, 2020, 10
  • [7] Accuracy and Validity of a Single Inertial Measurement Unit-Based System to Determine Upper Limb Kinematics for Medically Underserved Populations
    Hughes, Charmayne Mary Lee
    Tran, Bao
    Modan, Amir
    Zhang, Xiaorong
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [8] Data Valuation Algorithm for Inertial Measurement Unit-Based Human Activity Recognition
    Kim, Yeon-Wook
    Lee, Sangmin
    SENSORS, 2023, 23 (01)
  • [9] Stance and swing phase knee flexion recover at different rates following total knee arthroplasty: An inertial measurement unit study
    Chapman, Ryan M.
    Moschetti, Wayne E.
    Van Citters, Douglas W.
    JOURNAL OF BIOMECHANICS, 2019, 84 : 129 - 137
  • [10] Inertial Measurement Unit-Based Frozen Shoulder Identification from Daily Shoulder Tasks Using Machine Learning Approaches
    Liu, Chien-Pin
    Lu, Ting-Yang
    Wang, Hsuan-Chih
    Chang, Chih-Ya
    Hsieh, Chia-Yeh
    Chan, Chia-Tai
    SENSORS, 2024, 24 (20)