Metamaterial-Inspired Radiofrequency (RF) Shield With Reduced Specific Absorption Rate (SAR) and Improved Transmit Efficiency for UHF MRI

被引:23
作者
Chen, Haiwei [1 ]
Guo, Lei [1 ]
Li, Mingyan [1 ]
Destruel, Aurelien [1 ]
Liu, Chunyi [1 ]
Weber, Ewald [1 ]
Liu, Feng [1 ]
Crozier, Stuart [1 ]
机构
[1] Univ Queensland, Sch Informat Technol & Elect Engn, Brisbane, Qld 4072, Australia
基金
澳大利亚研究理事会;
关键词
Radio frequency; Coils; Magnetic resonance imaging; Metamaterials; Magnetic materials; Specific absorption rate; Absorption; Magnetic resonance image (MRI); metamaterial absorber; radio frequency (RF) coil; RF shield; specific absorption rate (SAR); ultra-high field MRI;
D O I
10.1109/TBME.2020.3022884
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To prevent the interferences between radiofrequency (RF) coils and other components in the magnetic resonance imaging (MRI) system such as gradient coils, it is essential to place an RF shield between the RF coils and gradient coils. However, the induced currents on conventional RF shields have negative influences on the RF coil performance. To reduce these influences, metamaterial absorbers (MA), a class of metamaterials exhibiting nearly unity absorption rate for the incident electromagnetic fields, can be employed for the design of a novel RF shield. However, the adoption of metamaterials in MRI systems is usually problematic because of the bulkiness of the metamaterial structure. In this work, capacitors and metallic interconnectors are used to miniaturize the MA so that the unit MA cell can operate at the Larmor frequencies of 7T and 9.4T MRI and stay compact. This MA-RF shield is used to improve the transmit efficiency of RF surface coils and reduce the specific absorption rate (SAR) in the region of interest (ROI). It is successfully demonstrated by simulations and experiments that, compared with conventional RF shield structure, the transmit efficiency can be enhanced by more than 32% and the peak SAR value can be reduced by 22% using the MA-RF shield. Moreover, it is observed that the transmit field penetration is improved when the surface coil is used with the MA-RF shield. This proof-of-concept study suggests a new practical way for the utilization of metamaterials in ultra-high field MRI applications.
引用
收藏
页码:1178 / 1189
页数:12
相关论文
共 48 条
  • [1] Metamaterial magnetoinductive lens performance as a function of field strength
    Algarin, Jose M.
    Freire, Manuel J.
    Breuer, Felix
    Behr, Volker C.
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2014, 247 : 9 - 14
  • [2] Analysis of the resolution of split-ring metamaterial lenses with application in parallel magnetic resonance imaging
    Algarin, Jose M.
    Freire, Manuel J.
    Lopez, Marcos A.
    Lapine, Mikhail
    Jakob, Peter M.
    Behr, Volker C.
    Marques, Ricardo
    [J]. APPLIED PHYSICS LETTERS, 2011, 98 (01)
  • [3] [Anonymous], 2010, MEDICAL ELECT EQUIPM
  • [4] Chen H, 2019, P 27 ANN M
  • [5] Chen H, 2018, P 26 ANN M ISMRM
  • [6] Improving B1 Efficiency and Signal-to-Noise-Ratio of a Surface Coil by a High-Impedance-Surface RF Shield for 7-T Magnetic Resonance Imaging
    Chen, Zhichao
    Solbach, Klaus
    Erni, Daniel
    Rennings, Andreas
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2017, 65 (03) : 988 - 997
  • [7] Design, simulation, and measurement of metamaterial absorber
    Cheng, Yongzhi
    Yang, Helin
    [J]. JOURNAL OF APPLIED PHYSICS, 2010, 108 (03)
  • [8] A Circuit-Based Model for the Interpretation of Perfect Metamaterial Absorbers
    Costa, Filippo
    Genovesi, Simone
    Monorchio, Agostino
    Manara, Giuliano
    [J]. IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2013, 61 (03) : 1201 - 1209
  • [9] Saturated double-angle method for rapid B1 plus mapping
    Cunningham, Charles H.
    Pauly, John M.
    Nayak, Krishna S.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) : 1326 - 1333
  • [10] On the applications of μr =-1 metamaterial lenses for magnetic resonance imaging
    Freire, Manuel J.
    Jelinek, Lukas
    Marques, Ricardo
    Lapine, Mikhail
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2010, 203 (01) : 81 - 90