Associations of indoor carbon dioxide concentrations, air temperature, and humidity with perceived air quality and sick building syndrome symptoms in Chinese homes

被引:42
|
作者
Hou, Jing [1 ]
Sun, Yuexia [1 ]
Dai, Xilei [1 ]
Liu, Junjie [1 ]
Shen, Xiong [1 ]
Tan, Hongwei [2 ]
Yin, Haiguo [3 ]
Huang, Kailiang [4 ]
Gao, Yao [5 ]
Lai, Dayi [1 ,6 ]
Hong, Weiping [1 ]
Zhai, Xinping [3 ]
Norback, Dan [7 ,8 ]
Chen, Qingyan [9 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin Key Lab Indoor Air Environm Qual Control, Tianjin 300350, Peoples R China
[2] Tongji Univ, Sch Mech Engn, Shanghai, Peoples R China
[3] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian, Shaanxi, Peoples R China
[4] Shenyang Jianzhu Univ, Dept Municipal & Environm Engn, Shenyang, Peoples R China
[5] Shenzhen Inst Bldg Res Co Ltd, Shenzhen, Peoples R China
[6] Shanghai Jiao Tong Univ, Sch Design, Dept Architecture, Shanghai, Peoples R China
[7] Uppsala Univ, Dept Med Sci, Uppsala, Sweden
[8] Univ Hosp, Uppsala, Sweden
[9] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
基金
中国国家自然科学基金;
关键词
CO2; home; odors; perceived dry air; relative humidity; sick building syndrome; RELATIVE-HUMIDITY; ORGANIC-COMPOUNDS; VOC EMISSIONS; VENTILATION; HEALTH; EXPOSURE; DAMPNESS; DRYNESS; IMPACT; TIME;
D O I
10.1111/ina.12810
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The indoor environment influences occupants' health. From March 1, 2018, to February 28, 2019, we continuously monitored indoor temperature (T), relative humidity (RH), and CO2 concentration in bedrooms via an online system in 165 residences that covered all five climate zones of China. Meanwhile, we asked one specific occupant in each home to complete questionnaires about perceived air quality and sick building syndrome (SBS) symptoms at the end of each month. Higher CO2 concentration was significantly associated with a higher percentage of perceived stuffy odor and skin SBS symptoms. Higher relative humidity was associated with higher percentage of perceived moldy odor and humid air, while lower RH was associated with a higher percentage of perceived dry air. Occupants who lived in residences with high RH were less likely to have mucosal and skin SBS symptoms (adjusted odds ratio (AOR): 0.73-0.78). However, the benefit of high humidity for perceived dry air and skin dryness symptoms is weaker if there is a high CO2 concentration level.
引用
收藏
页码:1018 / 1028
页数:11
相关论文
共 50 条
  • [21] EFFECT OF AIR HUMIDIFICATION ON THE SICK BUILDING SYNDROME AND PERCEIVED INDOOR AIR-QUALITY IN HOSPITALS - A 4 MONTH LONGITUDINAL-STUDY
    NORDSTROM, K
    NORBACK, D
    AKSELSSON, R
    OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1994, 51 (10) : 683 - 688
  • [22] How renovation activities may jeopardise indoor air quality: accounting for short and long-term symptoms of sick building syndrome in educational buildings
    Ismaeel, Walaa S. E.
    Alamoudy, Fatma O.
    Sameh, Raghad
    ARCHITECTURAL ENGINEERING AND DESIGN MANAGEMENT, 2023, 19 (04) : 360 - 377
  • [23] Indoor air quality and sick-building syndrome at a metro station in Tianjin, China
    Wang, Zukun
    Liu, Junjie
    Yao, Mingyao
    He, Mingtong
    Shang, Wenzhe
    Dong, Xinyue
    ENVIRONMENT INTERNATIONAL, 2024, 187
  • [24] Indoor Air Quality and Sick Building Syndrome Among Nigerian Laboratory University Workers
    Reuben, Usaku
    Ismail, Ahmad F.
    Ahmad, Abdul Latif
    Maina, Humphrey M.
    Daud, Aziah
    JOURNAL OF PHYSICAL SCIENCE, 2019, 30 (01) : 179 - 195
  • [25] Relationship between sick building syndrome and indoor air quality among hospital staff
    Arikan, Inci
    Tekin, Omer Faruk
    Erbas, Oguzhan
    MEDICINA DEL LAVORO, 2018, 109 (06): : 435 - 443
  • [26] Impact of temperature and humidity on the perception of indoor air quality
    Fang, L
    Clausen, G
    Fanger, PO
    INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1998, 8 (02): : 80 - 90
  • [27] Seasonal variation of indoor and outdoor air quality of nitrogen dioxide in homes with gas and electric stoves
    Dedele, Audrius
    Miskinyte, Aukse
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2016, 23 (17) : 17784 - 17792
  • [28] IMPACT OF CO2 CONCENTRATION ON INDOOR AIR QUALITY AND CORRELATION WITH RELATIVE HUMIDITY AND INDOOR AIR TEMPERATURE IN SCHOOL BUILDINGS IN SERBIA
    Lazovic, Ivan M.
    Stevanovic, Zarko M.
    Jovasevic-Stojanovic, Milena V.
    Zivkovic, Marija M.
    Banjac, Milos J.
    THERMAL SCIENCE, 2016, 20 : S297 - S307
  • [29] Indoor air quality and sick building syndrome: Are green buildings better than conventional buildings?
    Gawande, Sonal
    Tiwari, Rajnarayan R.
    Narayanan, Prakash
    Bhadri, Ashwin
    INDIAN JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2020, 24 (01) : 30 - 32
  • [30] Effects of ventilation rate per person and per floor area on perceived air quality, sick building syndrome symptoms, and decision-making
    Maddalena, R.
    Mendell, M. J.
    Eliseeva, K.
    Chan, W. R.
    Sullivan, D. P.
    Russell, M.
    Satish, U.
    Fisk, W. J.
    INDOOR AIR, 2015, 25 (04) : 362 - 370