Minimum detectable change for single-leg-stance-time in older adults

被引:82
作者
Goldberg, Allon [1 ,2 ]
Casby, Allison [1 ]
Wasielewski, Michelle [1 ]
机构
[1] Wayne State Univ, Dept Hlth Care Sci, Program Phys Therapy, Mobil Res Lab, Detroit, MI 48201 USA
[2] Wayne State Univ, Inst Gerontol, Detroit, MI 48202 USA
关键词
Single-leg-stance-time; Standard error of measurement; Minimum detectable change; RELIABILITY;
D O I
10.1016/j.gaitpost.2011.02.020
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Introduction: Knowledge of real change values for clinical balance measures can guide clinicians and researchers in interpretation of change scores to evaluate the effectiveness of therapeutic interventions. We are not aware of studies that have reported minimum change values for single-leg-stance-time (SLST) in community-dwelling older adults. A measure of absolute reliability, the standard error of measurement (SEM), can be used to compute minimum detectable change (MDC), a clinically useful indicator of change in performance exceeding that attributable to measurement error. The purpose of this study was to quantify MDC for SLST in community-dwelling older adults. Methods: Twenty-five adults (60-89 years) performed repeated trials of SLST. Relative and absolute reliability for SLST were quantified using the intraclass correlation coefficient and SEM. The MDC was computed from the SEM. Results: SEM was 8.7 s and MDC at the 95% confidence level was 24.1 s for SLST. SLST exhibited large measurement error (40.8%) and high minimum change (113.1%) percent values. Conclusion: Change in SLST performance should exceed 24.1 s to be considered real change. SLST exhibits poor absolute reliability and appears unlikely to be sensitive to detecting change in performance in geriatric clinical settings and research studies. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:737 / 739
页数:3
相关论文
共 13 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
Giorgetti M M, 1998, Physiother Res Int, V3, P274, DOI 10.1002/pri.150
[3]   Interpreting change scores of tests and measures used in physical therapy [J].
Haley, SM ;
Fragala-Pinkham, MA .
PHYSICAL THERAPY, 2006, 86 (05) :735-743
[4]  
Hollman John H, 2008, J Geriatr Phys Ther, V31, P53
[5]  
Portney L., 2010, Foundations of Clinical Research, V3rd
[6]   INTRACLASS CORRELATIONS - USES IN ASSESSING RATER RELIABILITY [J].
SHROUT, PE ;
FLEISS, JL .
PSYCHOLOGICAL BULLETIN, 1979, 86 (02) :420-428
[7]  
Springer Barbara A, 2007, J Geriatr Phys Ther, V30, P8
[8]  
Stratford P.W., 2004, PHYSIOTHER CAN, V56, P27, DOI [10.2310/6640.2004.15377, DOI 10.2310/6640.2004.15377]
[9]   Use of the standard error as a reliability index of interest: An applied example using elbow flexor strength data [J].
Stratford, PW ;
Goldsmith, CH .
PHYSICAL THERAPY, 1997, 77 (07) :745-750
[10]   One-leg balance is an important predictor of injurious falls in older persons [J].
Vellas, BJ ;
Wayne, SJ ;
Romero, L ;
Baumgartner, RN ;
Rubenstein, LZ ;
Garry, PJ .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1997, 45 (06) :735-738