Multispectral method for skin imaging: development and validation

被引:19
作者
Shi, Tianchen [1 ]
DiMarzio, Charles A. [1 ]
机构
[1] Northeastern Univ, CenSSIS, Opt Sci Lab, Dept Elect & Comp Engn, Boston, MA 02115 USA
关键词
D O I
10.1364/AO.46.008619
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A visible wide field multispectral system for comprehensive imaging of skin chromophores and blood vessels has been implemented, and an inhomogeneous Monte Carlo model of photon migration with randomly distributed blood vessels embedded in dermis has been developed. Predetermined nonlinear transforms have been obtained to address the nonlinear interdependent relationship among diffusive reflectance spectra, skin physiology properties, and geometry. For validation, in addition to real skin experiments and phantoms experiments, two alternative methods for blood vessel imaging have been used on the same set of subjects to compensate for the lack of ground truth for skin subsurface imaging. (C) 2007 Optical Society of America.
引用
收藏
页码:8619 / 8626
页数:8
相关论文
共 26 条
[1]  
ANDERSON RR, 1980, BIOENGINEERING SKIN, P253
[2]   MULTISPECTRAL TISSUE CHARACTERIZATION WITH TIME-RESOLVED DETECTION OF DIFFUSELY SCATTERED WHITE-LIGHT [J].
ANDERSSONENGELS, S ;
BERG, R ;
PERSSON, A ;
SVANBERG, S .
OPTICS LETTERS, 1993, 18 (20) :1697-1699
[3]   Sources of scattering in cervical tissue: determination of the scattering coefficient by confocal microscopy [J].
Collier, T ;
Follen, M ;
Malpica, A ;
Richards-Kortum, R .
APPLIED OPTICS, 2005, 44 (11) :2072-2081
[4]   The determination of in vivo human tissue optical properties and absolute chromophore concentrations using spatially resolved steady-state diffuse reflectance spectroscopy [J].
Doornbos, RMP ;
Lang, R ;
Aalders, MC ;
Cross, FW ;
Sterenborg, HJCM .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (04) :967-981
[5]   A DIFFUSION-THEORY MODEL OF SPATIALLY RESOLVED, STEADY-STATE DIFFUSE REFLECTANCE FOR THE NONINVASIVE DETERMINATION OF TISSUE OPTICAL-PROPERTIES INVIVO [J].
FARRELL, TJ ;
PATTERSON, MS ;
WILSON, B .
MEDICAL PHYSICS, 1992, 19 (04) :879-888
[6]  
FIRBANK M, 1999, PHYS MED BIOL, V44, P967
[7]  
Gill PR, 1981, PRACTICAL OPTIMIZATI, P136, DOI DOI 10.1137/1025065
[8]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[9]  
Jacques S. L., 2016, OREGON MED LASER CTR
[10]  
JACQUES SL, 1994, P SOC PHOTO-OPT INS, V2128, P231, DOI 10.1117/12.184904