Effective stabilization of the sacroiliac joints (SIJ) is essential, since spinal loading is transferred via the SIJ to the coxal bones, and further to the legs. We performed a biomechanical analysis of SIJ stability in terms of reduced SIJ shear force in standing posture using a validated static 3-D simulation model. This model contained 100 muscle elements, 8 ligaments, and 8 joints in trunk, pelvis, and upper legs. Initially, the model was set up to minimize the maximum muscle stress. In this situation, the trunk load was mainly balanced between the coxal bones by vertical SIJ shear force. An imposed reduction of the vertical SIJ shear by 20% resulted in 70% increase of SIJ compression force due to activation of hip flexors and counteracting hip extensors. Another 20% reduction of the vertical SIJ shear force resulted in further increase of SIJ compression force by 400%, due to activation of the transversely oriented M. transversus abdominis and pelvic floor muscles. The M. transversus abdominis crosses the SIJ and clamps the sacrum between the coxal bones. Moreover, the pelvic floor muscles oppose lateral movement of the coxal bones, which stabilizes the position of the sacrum between the coxal bones (the pelvic arc). Our results suggest that training of the M. transversus abdominis and the pelvic floor muscles could help to relieve SI-joint related pelvic pain.
引用
收藏
页码:415 / 424
页数:10
相关论文
共 35 条
  • [1] RECENT ADVANCES IN LUMBAR SPINAL MECHANICS AND THEIR CLINICAL-SIGNIFICANCE
    ADAMS, MA
    DOLAN, P
    [J]. CLINICAL BIOMECHANICS, 1995, 10 (01) : 3 - 19
  • [2] EMG activities of the quadratus lumborum and erector spinae muscles during flexion - Relaxation and other motor tasks
    Andersson, EA
    Oddsson, LIE
    Grundstrom, H
    Nilsson, J
    Thorstensson, A
    [J]. CLINICAL BIOMECHANICS, 1996, 11 (07) : 392 - 400
  • [3] A MODEL OF LOWER-EXTREMITY MUSCULAR ANATOMY
    BRAND, RA
    CROWNINSHIELD, RD
    WITTSTOCK, CE
    PEDERSEN, DR
    CLARK, CR
    VANKRIEKEN, FM
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (04): : 304 - 310
  • [4] THE SENSITIVITY OF MUSCLE FORCE PREDICTIONS TO CHANGES IN PHYSIOLOGICAL CROSS-SECTIONAL AREA
    BRAND, RA
    PEDERSEN, DR
    FRIEDERICH, JA
    [J]. JOURNAL OF BIOMECHANICS, 1986, 19 (08) : 589 - 596
  • [5] Brooke A., 1996, GAMS USERS GUIDE
  • [6] Intra-abdominal pressure mechanism for stabilizing the lumbar spine
    Cholewicki, J
    Juluru, K
    McGill, SM
    [J]. JOURNAL OF BIOMECHANICS, 1999, 32 (01) : 13 - 17
  • [7] Mechanical stability of the in vivo lumbar spine: Implications for injury and chronic low back pain
    Cholewicki, J
    McGill, SM
    [J]. CLINICAL BIOMECHANICS, 1996, 11 (01) : 1 - 15
  • [8] Recent advances in lumbar spinal mechanics and their significance for modelling
    Dolan, P
    Adams, MA
    [J]. CLINICAL BIOMECHANICS, 2001, 16 : S8 - S16
  • [9] FORCES ON PELVIS
    GOEL, VK
    SVENSSON, NL
    [J]. JOURNAL OF BIOMECHANICS, 1977, 10 (03) : 195 - 200
  • [10] GRACOVETSKY S, 1977, ORTHOP CLIN N AM, V8, P135