A novel technique to measure active tendon forces: application to the subscapularis tendon

被引:16
作者
Bull, AMJ
Reilly, P
Wallace, AL
Amis, AA
Emery, RJH
机构
[1] Univ London Imperial Coll Sci Technol & Med, Bagrit Ctr, London SW7 2AZ, England
[2] St Marys Hosp, London, England
[3] Univ London Imperial Coll Sci Technol & Med, Dept Musculoskeletal Surg, London, England
[4] Univ London Imperial Coll Sci Technol & Med, Dept Engn Mech, London, England
关键词
rotator cuff; subscapularis; force measurement; in vivo;
D O I
10.1007/s00167-004-0556-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This paper describes the design and use of a novel system for quantification of active tendon forces. An arthroscopically implantable force probe (AIFP) was inserted arthroscopically into the subscapularis tendon of the shoulder in vivo. The output response of this device was calibrated in situ with known forces applied to the tendon using an arthroscopic technique. On recovery of motor control following interscalene regional anaesthesia, the force within the tendon during active muscle contraction was measured. The AIFP was then retrieved through an arthroscopic portal. The technique showed that the subscapularis may produce forces of 250 N during maximum internal rotation of the shoulder.
引用
收藏
页码:145 / 150
页数:6
相关论文
共 15 条
[1]   THE EFFECT OF FUNCTIONAL KNEE-BRACES ON STRAIN ON THE ANTERIOR CRUCIATE LIGAMENT INVIVO [J].
BEYNNON, BD ;
POPE, MH ;
WERTHEIMER, CM ;
JOHNSON, RJ ;
FLEMING, BC ;
NICHOLS, CE ;
HOWE, JG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (09) :1298-1312
[2]   ANTERIOR CRUCIATE LIGAMENT STRAIN BEHAVIOR DURING REHABILITATION EXERCISES IN-VIVO [J].
BEYNNON, BD ;
FLEMING, BC ;
JOHNSON, RJ ;
NICHOLS, CE ;
RENSTROM, PA ;
POPE, MH .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1995, 23 (01) :24-34
[3]   Anterior cruciate ligament strain in-vivo: A review of previous work [J].
Beynnon, BD ;
Fleming, BC .
JOURNAL OF BIOMECHANICS, 1998, 31 (06) :519-525
[4]   LIGAMENTOUS RESTRAINTS TO ANTERIOR-POSTERIOR DRAWER IN THE HUMAN KNEE - BIOMECHANICAL STUDY [J].
BUTLER, DL ;
NOYES, FR ;
GROOD, ES .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1980, 62 (02) :259-270
[5]   Calibration and application of an intra-articular force transducer for the measurement of patellar tendon graft forces:: an in situ evaluation [J].
Fleming, BC ;
Good, L ;
Peura, GD ;
Beynnon, BD .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1999, 121 (04) :393-398
[6]   Factors influencing the output of an implantable force transducer [J].
Fleming, BC ;
Peura, GD ;
Beynnon, BD .
JOURNAL OF BIOMECHANICS, 2000, 33 (07) :889-893
[7]   Experimental rotator cuff repair - A preliminary study [J].
Gerber, C ;
Schneeberger, AG ;
Perren, SM ;
Nyffeler, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (09) :1281-1290
[8]   Isolated rupture of the subscapularis tendon - Results of operative repair [J].
Gerber, C ;
Hersche, O ;
Farron, A .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1996, 78A (07) :1015-1023
[9]   MECHANICAL STRENGTH OF REPAIRS OF THE ROTATOR CUFF [J].
GERBER, C ;
SCHNEEBERGER, AG ;
BECK, M ;
SCHLEGEL, U .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (03) :371-380
[10]   A COMPARATIVE ELECTROMYOGRAPHIC ANALYSIS OF THE SHOULDER DURING PITCHING - PROFESSIONAL VERSUS AMATEUR PITCHERS [J].
GOWAN, ID ;
JOBE, FW ;
TIBONE, JE ;
PERRY, J ;
MOYNES, DR .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1987, 15 (06) :586-590