Optimal energy-based seismic design of non-conventional Tuned Mass Damper (TMD) implemented via inter-story isolation

被引:156
作者
Reggio, Anna [1 ]
De Angelis, Maurizio [1 ]
机构
[1] Univ Roma La Sapienza, Dept Struct & Geotech Engn, I-00184 Rome, Italy
关键词
seismic risk mitigation; inter-story isolation; non-conventional Tuned Mass Damper (TMD); large mass ratio; energy balance; optimal design; SYSTEMS; BUILDINGS;
D O I
10.1002/eqe.2548
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Inter-story isolation, an effective strategy for mitigating the seismic risk of both new and existing buildings, has gained more and more interest in recent years as alternative to base isolation, whenever the latter results to be impractical, technically difficult or uneconomic. As suggested by the name, the technique consists in inserting flexible isolators at floor levels other than the base along the height of a multi-story building, thus realizing a non-conventional Tuned Mass Damper (TMD). Consistent with this, an optimal design methodology is developed in the present paper with the objective of achieving the global protection of both the structural portions separated by the inter-story isolation system, that is, the lower portion (below the isolation system) and the isolated upper portion (above the isolation system). The optimization procedure is formulated on the basis of an energy performance criterion that consists in maximizing the ratio between the energy dissipated in the isolation system and the input energy globally transferred to the entire structure. Numerical simulations, performed under natural accelerograms with different frequency content and considering increasing isolation levels along the height of a reference frame structure, are used to investigate the seismic performance of the optimized inter-story isolation systems. Copyright (c) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:1623 / 1642
页数:20
相关论文
共 38 条
[1]  
[Anonymous], STRONG GROUND MOT DA
[2]   Optimum parameters of tuned mass damper for damped main system [J].
Bakre, S. V. ;
Jangid, R. S. .
STRUCTURAL CONTROL & HEALTH MONITORING, 2007, 14 (03) :448-470
[3]   Optimized earthquake response of multi-storey buildings with seismic isolation at various elevations [J].
Charmpis, Dimos C. ;
Komodromos, Petros ;
Phocas, Marios C. .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2012, 41 (15) :2289-2310
[4]   Innovative seismic retrofitting strategy of added stories isolation system [J].
Chey M.-H. ;
Chase J.G. ;
Mander J.B. ;
Carr A.J. .
Frontiers of Structural and Civil Engineering, 2013, 7 (1) :13-23
[5]   Parametric control of structural responses using an optimal passive tuned mass damper under stationary Gaussian white noise excitations [J].
Min-Ho Chey ;
Jae-Ung Kim .
Frontiers of Structural and Civil Engineering, 2012, 6 (3) :267-280
[6]   Semi-active tuned mass damper building systems: Design [J].
Chey, Min-Ho ;
Chase, J. Geoffrey ;
Mander, John B. ;
Carr, Athol J. .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2010, 39 (02) :119-139
[7]   Semi-active tuned mass damper building systems: Application [J].
Chey, Min-Ho ;
Chase, J. Geoffrey ;
Mander, John B. ;
Carr, Athol J. .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2010, 39 (01) :69-89
[8]   Comparing response of SDF systems to near-fault and far-fault earthquake motions in the context of spectral regions [J].
Chopra, AK ;
Chintanapakdee, C .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2001, 30 (12) :1769-1789
[9]  
Ciampi V, 1996, STRUCTURAL DYNAMICS, VOLS. 1 & 2, P525
[10]   Dynamic response and optimal design of structures with large mass ratio TMD [J].
De Angelis, Maurizio ;
Perno, Salvatore ;
Reggio, Anna .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2012, 41 (01) :41-60