Comparison of arterial pressure waveform analysis with the lithium dilution technique to monitor cardiac output in anesthetized dogs

被引:24
作者
Chen, HC
Sinclair, MD
Dyson, DH
McDonell, WN [1 ]
Sears, WC
机构
[1] Univ Guelph, Dept Clin Studies, Guelph, ON N1G 2W1, Canada
[2] Univ Guelph, Dept Populat Med, Guelph, ON N1G 2W1, Canada
[3] Univ Guelph, Ontario Vet Coll, Guelph, ON N1G 2W1, Canada
关键词
D O I
10.2460/ajvr.2005.66.1430
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To assess agreement between arteria pressure waveform-derived cardiac output (PCO) and lithium dilution cardiac output (LiDCO) systems in measurements of various levels of cardiac output (CO) induced by changes in anesthetic depth and administration of inotropic drugs in dogs. Animals-6 healthy dogs. Procedure-Dogs were anesthetized on 2 occasions separated by at least 5 days. Inotropic drug administration (dopamine or dobutamine) was randomly assigned in a crossover manner. Following initial calibration of PCO measurements with a LiDCO measurement, 4 randomly assigned treatments were administered to vary CO; subsequently, concurrent pairs of PCO and LiDCO measurements were obtained. Treatments included a light plane of anesthesia, deep plane of anesthesia, continuous infusion of an inotropic drug (rate adjusted to achieve a mean arterial pressure of 65 to 80 mm Hg), and continuous infusion of an inotropic drug (7 mu g/kg/min). Results-Significant differences in PCO and LiDCO measurements were found during deep planes of anesthesia and with dopamine infusions but not during the light plane of anesthesia or with dobutamine infusions. The PCO system provided higher CO measurements than the LiDCO system during deep planes of anesthesia but lower CO measurements during dopamine infusions. Conclusions and Clinical Relevance-The PCO system tracked changes in CO in a similar direction as the LiDCO system. The PCO system provided better agreement with LiDCO measurements over time when hemodynamic conditions were similar to those during initial calibration. Recalibration of the PCO system is recommended when hemodynamic conditions or pressure waveforms are altered appreciably.
引用
收藏
页码:1430 / 1436
页数:7
相关论文
共 19 条
[1]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[2]   Comparison of lithium dilution and thermodilution cardiac output measurements in anaesthetised neonatal foals [J].
Corley, KTT ;
Donaldson, LL ;
Furr, MO .
EQUINE VETERINARY JOURNAL, 2002, 34 (06) :598-601
[3]   A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques [J].
Critchley, LAH ;
Critchley, JAJH .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) :85-91
[4]   COMPUTING FACTORS FOR EXACT 2-SIDED TOLERANCE LIMITS FOR A NORMAL-DISTRIBUTION [J].
EBERHARDT, KR ;
MEE, RW ;
REEVE, CP .
COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 1989, 18 (01) :397-413
[5]   COMPARISON OF AORTIC PULSE-WAVE CONTOUR ANALYSIS AND THERMODILUTION METHODS OF MEASURING CARDIAC-OUTPUT DURING ANESTHESIA IN THE DOG [J].
ENGLISH, JB ;
HODGES, MR ;
SENTKER, C ;
JOHANSEN, R ;
STANLEY, TH .
ANESTHESIOLOGY, 1980, 52 (01) :56-61
[6]   Lithium dilution cardiac output measurement: A clinical assessment of central venous and peripheral venous indicator injection [J].
Garcia-Rodriguez, C ;
Pittman, J ;
Cassell, CH ;
Sum-Ping, J ;
El-Moalem, H ;
Young, C ;
Mark, JB .
CRITICAL CARE MEDICINE, 2002, 30 (10) :2199-2204
[7]  
Hamilton TT, 2002, ANN THORAC SURG, V74, pS1408
[8]  
Jonas Max M, 2002, Curr Opin Crit Care, V8, P257, DOI 10.1097/00075198-200206000-00010
[9]   Comparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output [J].
Kurita, T ;
Morita, K ;
Kato, S ;
Kikura, M ;
Horie, M ;
Ikeda, K .
BRITISH JOURNAL OF ANAESTHESIA, 1997, 79 (06) :770-775
[10]   Lithium dilution cardiac output measurement: A comparison with thermodilution [J].
Linton, R ;
Band, D ;
OBrien, T ;
Jonas, M ;
Leach, R .
CRITICAL CARE MEDICINE, 1997, 25 (11) :1796-1800