Assessment of odours from sewage treatment works by an electronic nose, H2S analysis and olfactometry

被引:123
作者
Stuetz, RM [1 ]
Fenner, RA [1 ]
Engin, G [1 ]
机构
[1] Univ Hertfordshire, Water Engn Res Grp, Hatfield AL10 9AB, Herts, England
关键词
electronic nose; H2S; odour; odour concentration; olfactometry; sewage treatment; sensors; threshold odour number (TON);
D O I
10.1016/S0043-1354(98)00246-2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An electronic nose based on a non-specific conducting polymer array was evaluated against sewage odour concentrations From ten sewage treatment works. Sensor responses from the twelve sensor array were compared using canonical correlation (a data reduction technique) with threshold odour numbers (TON) made by dynamic dilution olfactometry. The results suggest that for sewage odours from a range of locations within different treatment works, no universal relationship is present, whereas a strong correlation can be produced between TON and the electronic nose responses (as represented by a canonical variable) for sewage odours from a single works. Further correlations were achieved between the odour potential of a liquid sewage and the NOSE output of a quiescent sewage liquor. Hydrogen sulphide (H2S) concentrations, commonly used as measures of odour strength, were also compared with TON and found not to be a good marker compound for measuring these sewage odour concentrations. The results demonstrated the ability of an electronic nose to respond to sewage odours over a range of odour concentrations (125-781066 odour units/m(3)) and suggest the potential application of such an instrument to monitor odour emission;in a sewage works, as well as assessing the efficiency of odour abatement units. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:453 / 461
页数:9
相关论文
共 18 条
  • [1] [Anonymous], THESIS U HERTFORDSHI
  • [2] Odour measurement - Factors affecting olfactometry panel performance
    Bliss, PJ
    Schulz, TJ
    Senger, T
    Kaye, RB
    [J]. WATER SCIENCE AND TECHNOLOGY, 1996, 34 (3-4) : 549 - 556
  • [3] *COMM EUR NORM, 1995, EUR PREST CEN PREN O
  • [4] ASSESSMENT OF ODORS FROM LIVESTOCK WASTES BY A PHOTOIONIZATION DETECTOR, AN ELECTRONIC NOSE, OLFACTOMETRY AND GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    HOBBS, PJ
    MISSELBROOK, TH
    PAIN, BF
    [J]. JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1995, 60 (02): : 137 - 144
  • [5] HOBSON J, 1995, J CHART INST WATER E, V9, P458
  • [6] HOBSON J, 1997, WATER QUALITY IN JUL, P21
  • [7] FORGETTING, EUROPE, TRADITION, PHILOSOPHY
    HODGE, J
    [J]. JOURNAL OF THE BRITISH SOCIETY FOR PHENOMENOLOGY, 1995, 26 (03) : 255 - 267
  • [8] THE ELECTRONIC NOSE AND ITS APPLICATION TO THE MANUFACTURE OF FOOD-PRODUCTS
    HODGINS, D
    SIMMONDS, D
    [J]. JOURNAL OF AUTOMATIC CHEMISTRY, 1995, 17 (05): : 179 - 185
  • [9] Manly B. F., 1986, MULTIVARIATE STAT ME
  • [10] MCGOVERN JE, 1994, I WATER ENV MAN P OD, P45