An EMD based Method for Reduction of Ballistocardiogram Artifact from EEG Studies of Evoked Potentials

被引:0
作者
Javed, Ehtasham [1 ]
Faye, Ibrahima [2 ]
Malik, Aamir Saeed [1 ]
Abdullah, Jafri Malin [3 ]
机构
[1] Univ Teknol PETRONAS, Ctr Intelligent Signal & Imaging Res, Dept Elect & Elect Engn, Perak, Malaysia
[2] Univ Teknol PETRONAS, Ctr Intelligent Signal & Imaging Res, Dept Fundamental & Appl Sci, Perak, Malaysia
[3] Hosp Univ Sains Malaysia, Dept Neurosci, Ctr Neurosci Serv & Res, Kelantan, Malaysia
来源
2015 IEEE 14TH INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND APPLICATIONS (ICMLA) | 2015年
关键词
Ballistocardiogram artifact; Simultaneous EEG & fMRI; Event Related Potentials; Empirical Mode Decomposition; FEATURE-EXTRACTION; REMOVAL; FMRI;
D O I
10.1109/ICMLA.2015.81
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Multi-modality data acquisition is a topic of research that gained interest in the recent years. It provides the opportunity to gather detailed information for analysis. Simultaneous electroencephalography (EEG) and functional magnetic resonance imaging is one good example of it. The information we get after fusing data from EEG and fMRI have both high temporal and spatial resolution. On the other side, this EEG recording suffers from some additional artifacts due to the fMRI environment, in particular, the Ballistocardiogram artifact. In this article, a new method of removing Ballistocardiogram Artifact from evoked potential studies is proposed. The method does not require any reference signal or prior information. The results presented are using the data of three subjects (volunteers). The results show that the proposed method can efficiently reduce Ballistocardiogram artifact and has performed better compared to the conventional methods.
引用
收藏
页码:1199 / 1203
页数:5
相关论文
共 15 条
[1]   A new approach for EEG feature extraction in P300-based lie detection [J].
Abootalebi, Vahid ;
Moradi, Mohammad Hassan ;
Khalilzadeh, Mohammad Ali .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2009, 94 (01) :48-57
[2]   Identification of EEG events in the MR scanner: The problem of pulse artifact and a method for its subtraction [J].
Allen, PJ ;
Polizzi, G ;
Krakow, K ;
Fish, DR ;
Lemieux, L .
NEUROIMAGE, 1998, 8 (03) :229-239
[3]   Properties of the ballistocardiogram artefact as revealed by EEG recordings at 1.5, 3 and 7 T static magnetic field strength [J].
Debener, Stefan ;
Mullinger, Karen J. ;
Mazy, Rami K. ;
Bowtell, Richard W. .
INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2008, 67 (03) :189-199
[4]   Improved quality of auditory event-related potentials recorded simultaneously with 3-T fMRI: Removal of the ballistocardiogram artefact [J].
Debener, Stefan ;
Strobel, Alexander ;
Sorger, Bettina ;
Peters, Judith ;
Kranczioch, Cornelia ;
Engel, Andreas K. ;
Goebel, Rainer .
NEUROIMAGE, 2007, 34 (02) :587-597
[5]   Removing Ballistocardiogram Artifact From EEG Using Short- and Long-Term Linear Predictor [J].
Ferdowsi, Saideh ;
Sanei, Saeid ;
Abolghasemi, Vahid ;
Nottage, Judith ;
O'Daly, Owen .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (07) :1900-1911
[6]   Music training and working memory: An ERP study [J].
George, Elyse M. ;
Coch, Donna .
NEUROPSYCHOLOGIA, 2011, 49 (05) :1083-1094
[7]   EEG based brain source localization comparison of sLORETA and eLORETA [J].
Jatoi, Munsif Ali ;
Kamel, Nidal ;
Malik, Aamir Saeed ;
Faye, Ibrahima .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (04) :713-721
[8]   A survey of methods used for source localization using EEG signals [J].
Jatoi, Munsif Ali ;
Kamel, Nidal ;
Malik, Aarnir Saeed ;
Faye, Ibrahima ;
Begum, Tahamina .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2014, 11 :42-52
[9]  
Javed E, 2014, LECT NOTES COMPUT SC, V8835, P186, DOI 10.1007/978-3-319-12640-1_23
[10]   Ballistocardiographic artifact removal from simultaneous EEG-fMRI using an optical motion-tracking system [J].
LeVan, Pierre ;
Maclaren, Julian ;
Herbst, Michael ;
Sostheim, Rebecca ;
Zaitsev, Maxim ;
Hennig, Juergen .
NEUROIMAGE, 2013, 75 :1-11