Parameter study on the fouling characteristics of the H-type finned tube heat exchangers

被引:76
作者
Wang, Fei-Long [1 ]
He, Ya-Ling [1 ]
Tang, Song-Zhen [1 ]
Tong, Zi-Xiang [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermofluid Sci & Engn, Minist Educ, Xian 710049, Shaanxi, Peoples R China
关键词
Waste heat recovery; H-type finned tube; Orthogonal design; Fouling resistance; Heat transfer; DEPOSITION CHARACTERISTICS; PARTICLE DEPOSITION; PRESSURE-DROP; 10; ROWS; SYSTEMS; IMPACT; SURFACE; MODEL; BANK;
D O I
10.1016/j.ijheatmasstransfer.2017.04.107
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, numerical simulations were performed for the fouling characteristics and heat transfer performance after fouling on the H-type finned tube heat exchangers, and the optimum parameters studies were also conducted according to the orthogonal array design method. Firstly, the effect of row number on the fouling results were discussed. It was found that there was a critical row number N-cr = 6, and the fouling results will reach a constant value when the row number is larger than the critical row number. Then, the orthogonal array design method was employed to design the test arrangements, and the effects of six geometric parameters and two operating conditions on the fouling results as well as heat transfer performance after fouling were investigated. The order of the effects of each factor and the optimum parameters corresponding to the least fouling and best heat transfer performance after fouling were also determined. At last, a correlation of the Nusselt number after fouling Nut with the geometric parameters and the operating conditions was obtained. The results showed that the optimum conditions we determined using the orthogonal array design method do have less fouling or have better heat transfer performance after fouling than the reference cases in the test arrangements. The correlation of Nut has good prediction accuracy, and it can be useful in the design and evaluation of heat exchanger in dusty environment. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:367 / 378
页数:12
相关论文
共 34 条
[1]   A MECHANISTIC DESCRIPTION OF ASH DEPOSITION DURING PULVERIZED COAL COMBUSTION - PREDICTIONS COMPARED WITH OBSERVATIONS [J].
BAXTER, LL ;
DESOLLAR, RW .
FUEL, 1993, 72 (10) :1411-1418
[2]  
Beek M.C.V., 2001, THESIS
[3]   Experimental Analysis of the Effects of Particulate Fouling on Heat Exchanger Heat Transfer and Air-Side Pressure Drop for a Hybrid Dry Cooler [J].
Bell, Ian H. ;
Groll, Eckhard A. ;
Koenig, Holger .
HEAT TRANSFER ENGINEERING, 2011, 32 (3-4) :264-271
[4]   Air-side particulate fouling of microchannel heat exchangers: Experimental comparison of air-side pressure drop and heat transfer with plate-fin heat exchanger [J].
Bell, Ian H. ;
Groll, Eckhard A. .
APPLIED THERMAL ENGINEERING, 2011, 31 (05) :742-749
[5]   EFFECTS OF GEOMETRIC PARAMETERS FOR WAVY FINNED-TUBE HEAT EXCHANGER IN TURBULENT FLOW: A CFD MODELING [J].
Bhuiyan, Arafat A. ;
Amin, M. Ruhul ;
Naser, Jamal ;
Islam, A. K. M. Sadrul .
FRONTIERS IN HEAT AND MASS TRANSFER, 2015, 6 (01) :1-11
[6]  
Bohnet M., 1987, CHEM ENG TECHNOL, V10, P113, DOI DOI 10.1002/CEAT.270100115
[7]   Design of a novel, intensified heat exchanger for reduced fouling rates [J].
Bouris, D ;
Konstantinidis, E ;
Balabani, S ;
Castiglia, D ;
Bergeles, G .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (18) :3817-3832
[8]   Experimental Investigation of Heat Transfer and Pressure Drop Characteristics of H-type Finned Tube Banks [J].
Chen, Heng ;
Wang, Yungang ;
Zhao, Qinxin ;
Ma, Haidong ;
Li, Yuxin ;
Chen, Zhongya .
ENERGIES, 2014, 7 (11) :7094-7104
[9]   A numerical study of the deposition characteristics of sulfuric acid vapor on heat exchanger surfaces [J].
Han, H. ;
He, Y. L. ;
Tao, W. Q. .
CHEMICAL ENGINEERING SCIENCE, 2013, 101 :620-630
[10]   A parameter study of tube bundle heat exchangers for fouling rate reduction [J].
Han, Hui ;
He, Ya-Ling ;
Tao, Wen-Quan ;
Li, Yin-Shi .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 72 :210-221