Comparison of phantom materials for use in quality assurance of microbeam radiation therapy

被引:27
|
作者
Cameron, Matthew [1 ]
Cornelius, Iwan [2 ]
Cutajar, Dean [1 ]
Davis, Jeremy [1 ]
Rosenfeld, Anatoly [1 ]
Lerch, Michael [1 ]
Guatelli, Susanna [1 ]
机构
[1] Univ Wollongong, CMRP, Wollongong, NSW 2522, Australia
[2] Australian Synchrotron, Melbourne, Vic 3168, Australia
基金
英国医学研究理事会;
关键词
microbeam radiation therapy; polymer phantoms; dosimetry; Monte Carlo; Geant4; WATER EQUIVALENCE; SOLID PHANTOMS; DOSIMETRY; SIMULATION; RAYS;
D O I
10.1107/S1600577517005641
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Microbeam radiation therapy (MRT) is a promising radiotherapy modality that uses arrays of spatially fractionated micrometre-sized beams of synchrotron radiation to irradiate tumours. Routine dosimetry quality assurance (QA) prior to treatment is necessary to identify any changes in beam condition from the treatment plan, and is undertaken using solid homogeneous phantoms. Solid phantoms are designed for, and routinely used in, megavoltage X-ray beam radiation therapy. These solid phantoms are not necessarily designed to be water-equivalent at low X-ray energies, and therefore may not be suitable for MRT QA. This work quantitatively determines the most appropriate solid phantom to use in dosimetric MRT QA. Simulated dose profiles of various phantom materials were compared with those calculated in water under the same conditions. The phantoms under consideration were RMI457 Solid Water (Gammex-RMI, Middleton, WI, USA), Plastic Water (CIRS, Norfolk, VA, USA), Plastic Water DT (CIRS, Norfolk, VA, USA), PAGAT (CIRS, Norfolk, VA, USA), RW3 Solid Phantom (PTW Freiburg, Freiburg, Germany), PMMA, Virtual Water (Med-Cal, Verona, WI, USA) and Perspex. RMI457 Solid Water and Virtual Water were found to be the best approximations for water in MRT dosimetry (within +/- 3% deviation in peak and 6% in valley). RW3 and Plastic Water DT approximate the relative dose distribution in water (within +/- 3% deviation in the peak and 5% in the valley). PAGAT, PMMA, Perspex and Plastic Water are not recommended to be used as phantoms for MRT QA, due to dosimetric discrepancies greater than 5%.
引用
收藏
页码:866 / 876
页数:11
相关论文
共 50 条
  • [31] Feasibility study of multi-purpose quality assurance phantom for pretreatment verification of volumetric modulated arc therapy
    Won, H. S.
    Chung, J. B.
    Eom, K. Y.
    Hwang, D. G.
    Kang, S. W.
    Suh, T. S.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (03): : 279 - 287
  • [32] Identifying optimal clinical scenarios for synchrotron microbeam radiation therapy: A treatment planning study
    Smyth, Lloyd M. L.
    Day, Liam R.
    Woodford, Katrina
    Rogers, Peter A. W.
    Crosbie, Jeffrey C.
    Senthi, Sashendra
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 60 : 111 - 119
  • [33] Evaluation of water-mimicking solid phantom materials for use in HDR and LDR brachytherapy dosimetry
    Schoenfeld, Andreas A.
    Thieben, Maike
    Harder, Dietrich
    Poppe, Bjoern
    Chofor, Ndimofor
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (24) : N561 - N572
  • [34] Medical physics aspects of the synchrotron radiation therapies: Microbeam radiation therapy (MRT) and synchrotron stereotactic radiotherapy (SSRT)
    Braeuer-Krisch, Elke
    Adam, Jean-Francois
    Alagoz, Enver
    Bartzsch, Stefan
    Crosbie, Jeff
    DeWagter, Carlos
    Dipuglia, Andrew
    Donzelli, Mattia
    Doran, Simon
    Fournier, Pauline
    Kalef-Ezra, John
    Kock, Angela
    Lerch, Michael
    McErlean, Ciara
    Oelfke, Uwe
    Olko, Pawel
    Petasecca, Marco
    Povoli, Marco
    Rosenfeld, Anatoly
    Siegbahn, Erik A.
    Sporea, Dan
    Stugu, Bjarne
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (06): : 568 - 583
  • [35] Dynamic anthropomorphic thorax phantom for quality assurance of motion management in radiotherapy
    Abdollahi, Sara
    Mowlavi, Ali Asghar
    Yazdi, Mohammad Hadi Hadizadeh
    Ceberg, Sofie
    Aznar, Marianne Camille
    Tabrizi, Fatemeh Varshoee
    Salek, Roham
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 30
  • [36] Monte Carlo dose enhancement studies in microbeam radiation therapy
    Martinez-Rovira, I.
    Prezado, Y.
    MEDICAL PHYSICS, 2011, 38 (07) : 4430 - 4439
  • [37] The Combination of Temporal and Spatial Dose Fractionation in Microbeam Radiation Therapy
    Stolz, Jessica
    Rogal, Kristina
    Bicher, Sandra
    Winter, Johanna
    Ahmed, Mabroor
    Raulefs, Susanne
    Combs, Stephanie E.
    Bartzsch, Stefan H.
    Schmid, Thomas E.
    BIOMEDICINES, 2025, 13 (03)
  • [38] Scatter factors assessment in microbeam radiation therapy
    Prezado, Y.
    Martinez-Rovira, I.
    Sanchez, M.
    MEDICAL PHYSICS, 2012, 39 (03) : 1234 - 1238
  • [39] A comparative analysis of multichannel Data Acquisition Systems for quality assurance in external beam radiation therapy
    Fuduli, I.
    Porumb, C.
    Espinoza, A. A.
    Aldosari, A. H.
    Carolan, M.
    Lerch, M. L. F.
    Metcalfe, P.
    Rosenfeld, A. B.
    Petasecca, M.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [40] Improving intensity-modulated radiation therapy quality assurance by adopting statistical process control
    Cui, T.
    Peng, J-X
    Jin, X-L
    Chu, X-G
    Zhang, J.
    Cui, L-Z
    Xing, X-F
    CANCER RADIOTHERAPIE, 2022, 26 (03): : 427 - 432