Comparison of phantom materials for use in quality assurance of microbeam radiation therapy

被引:27
|
作者
Cameron, Matthew [1 ]
Cornelius, Iwan [2 ]
Cutajar, Dean [1 ]
Davis, Jeremy [1 ]
Rosenfeld, Anatoly [1 ]
Lerch, Michael [1 ]
Guatelli, Susanna [1 ]
机构
[1] Univ Wollongong, CMRP, Wollongong, NSW 2522, Australia
[2] Australian Synchrotron, Melbourne, Vic 3168, Australia
基金
英国医学研究理事会;
关键词
microbeam radiation therapy; polymer phantoms; dosimetry; Monte Carlo; Geant4; WATER EQUIVALENCE; SOLID PHANTOMS; DOSIMETRY; SIMULATION; RAYS;
D O I
10.1107/S1600577517005641
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Microbeam radiation therapy (MRT) is a promising radiotherapy modality that uses arrays of spatially fractionated micrometre-sized beams of synchrotron radiation to irradiate tumours. Routine dosimetry quality assurance (QA) prior to treatment is necessary to identify any changes in beam condition from the treatment plan, and is undertaken using solid homogeneous phantoms. Solid phantoms are designed for, and routinely used in, megavoltage X-ray beam radiation therapy. These solid phantoms are not necessarily designed to be water-equivalent at low X-ray energies, and therefore may not be suitable for MRT QA. This work quantitatively determines the most appropriate solid phantom to use in dosimetric MRT QA. Simulated dose profiles of various phantom materials were compared with those calculated in water under the same conditions. The phantoms under consideration were RMI457 Solid Water (Gammex-RMI, Middleton, WI, USA), Plastic Water (CIRS, Norfolk, VA, USA), Plastic Water DT (CIRS, Norfolk, VA, USA), PAGAT (CIRS, Norfolk, VA, USA), RW3 Solid Phantom (PTW Freiburg, Freiburg, Germany), PMMA, Virtual Water (Med-Cal, Verona, WI, USA) and Perspex. RMI457 Solid Water and Virtual Water were found to be the best approximations for water in MRT dosimetry (within +/- 3% deviation in peak and 6% in valley). RW3 and Plastic Water DT approximate the relative dose distribution in water (within +/- 3% deviation in the peak and 5% in the valley). PAGAT, PMMA, Perspex and Plastic Water are not recommended to be used as phantoms for MRT QA, due to dosimetric discrepancies greater than 5%.
引用
收藏
页码:866 / 876
页数:11
相关论文
共 50 条
  • [1] Film dosimetry studies for patient specific quality assurance in microbeam radiation therapy
    Ocadiz, Alexandre
    Livingstone, Jayde
    Donzelli, Mattia
    Bartzsch, Stefan
    Nemoz, Christian
    Kefs, Samy
    Pellicioli, Paolo
    Giraud, Jean-Yves
    Balosso, Jacques
    Krisch, Michael
    Brauer-Krisch, Elke
    Serduc, Raphael
    Adam, Jean-Francois
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 65 : 227 - 237
  • [2] X-Tream quality assurance in synchrotron X-ray microbeam radiation therapy
    Fournier, Pauline
    Cornelius, Iwan
    Donzelli, Mattia
    Requardt, Herwig
    Nemoz, Christian
    Petasecca, Marco
    Brauer-Krisch, Elke
    Rosenfeld, Anatoly
    Lerch, Michael
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 1180 - 1190
  • [3] Comprehensive Quality Assurance Phantom for the Small Animal Radiation Research Platform
    Jermoumi, M.
    Korideck, H.
    Zygmanski, P.
    Berbeco, R.
    Makrigiorgos, G.
    Cormack, R.
    Ngwa, W.
    MEDICAL PHYSICS, 2014, 41 (06) : 242 - 242
  • [4] Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy
    Letourneau, Daniel
    Publicover, Julia
    Kozelka, Jakub
    Moseley, Douglas J.
    Jaffray, David A.
    MEDICAL PHYSICS, 2009, 36 (05) : 1813 - 1821
  • [5] Development of a polystyrene phantom for quality assurance of a Gamma Knife®
    Choi, Yona
    Chun, Kook Jin
    Bahng, Jungbae
    Choi, Sang Hyoun
    Cho, Gyu Seok
    Kim, Tae Hoon
    Yang, Hye Jeong
    Seo, Yeong Chan
    Chung, Hyun-Tai
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (08) : 2935 - 2940
  • [6] Comprehensive quality assurance phantom for the small animal radiation research platform (SARRP)
    Jermoumi, M.
    Korideck, H.
    Bhagwat, M.
    Zygmanski, P.
    Makrigiogos, G. M.
    Berbeco, R. I.
    Cormack, R. C.
    Ngwa, W.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (05): : 529 - 535
  • [7] Experimental optimisation of the X-ray energy in microbeam radiation therapy
    Livingstone, Jayde
    Stevenson, Andrew W.
    Hausermann, Daniel
    Adam, Jean-Francois
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 : 156 - 161
  • [8] A point kernel algorithm for microbeam radiation therapy
    Debus, Charlotte
    Oelfke, Uwe
    Bartzsch, Stefan
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (21) : 8341 - 8359
  • [9] Incorporating Clinical Imaging into the Delivery of Microbeam Radiation Therapy
    Paino, Jason
    Barnes, Micah
    Engels, Elette
    Davis, Jeremy
    Guatelli, Susanna
    de Veer, Michael
    Hall, Chris
    Hausermann, Daniel
    Tehei, Moeava
    Corde, Stephanie
    Rosenfeld, Anatoly
    Lerch, Michael
    APPLIED SCIENCES-BASEL, 2021, 11 (19):
  • [10] On the use of computed radiography plates for quality assurance of intensity modulated radiation therapy dose distributions
    Day, R. A.
    Sankar, A. P.
    Nailon, W. H.
    MacLeod, A. S.
    MEDICAL PHYSICS, 2011, 38 (02) : 632 - 645