Digital enhancement of radiographs for assessment of interproximal dental caries

被引:13
作者
Seneadza, V. [1 ]
Koob, A. [1 ]
Kaltschmitt, J. [2 ]
Staehle, H. J. [2 ]
Duwenhoegger, J.
Eickholz, P. [3 ]
机构
[1] Univ Heidelberg Hosp, Clin Oral Dent & Maxillofacial Dis, Dept Conservat Dent, Dept Prosthodont, Heidelberg, Germany
[2] Univ Heidelberg Hosp, Clin Oral Dent & Maxillofacial Dis, Dept Conservat Dent, Sect Periodont, Heidelberg, Germany
[3] Hosp Johann Wolfgang Goethe Univ, Ctr Dent Oral & Maxillofacial, Dept Periodontol, D-6000 Frankfurt, Germany
关键词
dental caries; radiology; diagnostic X-ray; radiographic image enhancement; validity;
D O I
10.1259/dmfr/51572889
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Evaluation of a particular digital caries image-enhancing mode (filter) for its effect on the validity of measurements of caries lesion depth. Methods: Standardized radiographs of 44 extracted teeth exhibiting interproximal caries lesions were obtained. Six radiographs were obtained of each tooth and digitized. Four radiographs were made using D-speed film with and without soft tissue scattering equivalent (STSE) at normal exposure time (0.32 s) and underexposed (0.16 s). Two were made using E-speed film with STSE normally (0.16 s) and underexposed (0.08 s). On each of the 264 radiographs, 4 independent examiners measured the central depth (CD) of 1 carious lesion per tooth both on the unchanged radiographic image and after use of the filter. Histometric CD assessments provided a gold standard for comparison with the radiographic measurements (validity). Repeated measures ANOVA was calculated for validity in relation to examiner, lesion type, filter, film type, exposure time and STSE. Results: The lesion type was identified to statistically significantly influence the validity of CD measurements. Examiner in combination with defect type (P < 0.001), filter (P = 0.017), exposure (P = 0.027) and film type (P = 0.044) had an additional albeit small effect. Conclusions: The lesion type significantly influenced the validity of CD measurements: enamel lesions were less underestimated than dentin lesions.
引用
收藏
页码:142 / 148
页数:7
相关论文
共 36 条
  • [1] A, 2002, AUST DENT J, V47, P27
  • [2] Angmar-Mansson B, 1993, Adv Dent Res, V7, P70
  • [3] Benn D K, 1989, Quintessence Int, V20, P131
  • [4] BERM DK, 1994, DENTOMAXILLOFAC RAD, V23, P69
  • [5] de Araujo EAF, 2005, AM J DENT, V18, P241
  • [6] Digital radiography of interproximal caries: Effect of different filters
    Eickholz, P
    Kolb, I
    Lenhard, M
    Hassfeld, S
    Staehle, HJ
    [J]. CARIES RESEARCH, 1999, 33 (03) : 234 - 241
  • [7] Eickholz P, 1997, OPER DENT, V22, P222
  • [8] Influence of displayed image size on radiographic detection of approximal caries
    Haak, R
    Wicht, MJ
    Nowak, G
    Hellmich, M
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (04) : 242 - 246
  • [9] In vitro comparison of Kodak Ultra-speed, Ektaspeed, and Ektaspeed Plus, and Agfa M2 comfort dental x-ray films for the detection of caries
    Hintze, H
    Christoffersen, L
    Wenzel, A
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1996, 81 (02): : 240 - 244
  • [10] Influence of the validation method on diagnostic accuracy for caries. A comparison of six digital and two conventional radiographic systems
    Hintze, H
    Wenzel, A
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (01) : 44 - 49