Improved cantilever profiles for sensor elements

被引:28
作者
Fernando, Sanchitha [1 ]
Austin, Michael [1 ]
Chaffey, Jason [2 ]
机构
[1] RMIT Univ, Sch Elect & Comp Engn, Melbourne, Vic 3001, Australia
[2] Mems ID, Mini FAB, Scoresby, Vic 3179, Australia
关键词
D O I
10.1088/0022-3727/40/24/009
中图分类号
O59 [应用物理学];
学科分类号
摘要
The problem of simultaneously enhancing sensitivity and noise immunity of microcantilevers is investigated. The dependence of deflection and resonant frequency of a microcantilever on its dimensions is studied. A principle to increase deflection and resonant frequency simultaneously is established. Several cantilevers agreeing with this principle are investigated using analytical models and are compared with FEM simulations. Using these results, a cantilever profile that achieves a larger deflection and a larger resonant frequency compared with uniform cantilevers is proposed to be used in sensor elements.
引用
收藏
页码:7652 / 7655
页数:4
相关论文
共 19 条
[1]   ADSORPTION-INDUCED SURFACE STRESS AND ITS EFFECTS ON RESONANCE FREQUENCY OF MICROCANTILEVERS [J].
CHEN, GY ;
THUNDAT, T ;
WACHTER, EA ;
WARMACK, RJ .
JOURNAL OF APPLIED PHYSICS, 1995, 77 (08) :3618-3622
[2]   Resonant microcantilever type chemical sensors: analytical modeling in view of optimization [J].
Dufour, I ;
Fadel, L .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 91 (1-3) :353-361
[3]  
Fernando SN, 2005, P SOC PHOTO-OPT INS, V5649, P265, DOI 10.1117/12.582278
[4]   Chemical characterization of dissolved organic matter in Hiroshima Bay, Japan [J].
Fukushima, T ;
Ishibashi, T ;
Imai, A .
ESTUARINE COASTAL AND SHELF SCIENCE, 2001, 53 (01) :51-62
[5]  
Gere J.M., 1991, MECH MATER, V3rd SI, DOI DOI 10.1007/978-1-4899-3124-5
[6]   OBSERVATION OF A CHEMICAL-REACTION USING A MICROMECHANICAL SENSOR [J].
GIMZEWSKI, JK ;
GERBER, C ;
MEYER, E ;
SCHLITTLER, RR .
CHEMICAL PHYSICS LETTERS, 1994, 217 (5-6) :589-594
[7]   Enhancing chemi-mechanical transduction in microcantilever chemical sensing by surface modification [J].
Headrick, JJ ;
Sepaniak, MJ ;
Lavrik, NV ;
Datskos, PG .
ULTRAMICROSCOPY, 2003, 97 (1-4) :417-424
[8]   Improved atomic force microscope cantilever performance by ion beam modification [J].
Hodges, AR ;
Bussmann, KM ;
Hoh, JH .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (10) :3880-3883
[9]   NATURAL FREQUENCIES OF A BEAM WITH VARYING SECTION PROPERTIES [J].
JATEGAONKAR, R ;
CHEHIL, DS .
JOURNAL OF SOUND AND VIBRATION, 1989, 133 (02) :303-322
[10]   Novel cantilever for biosensing applications [J].
Karhade, OG ;
Chiluveru, SS ;
Apte, PR .
Microfluidics, BioMEMS, and Medical Microsystems III, 2005, 5718 :48-53