Cricoid pressure training: How useful are descriptions of force?

被引:17
作者
Escott, MEA [1 ]
Owen, H [1 ]
Strahan, AD [1 ]
Plummer, JL [1 ]
机构
[1] Flinders Univ S Australia, Flinders Med Ctr, Dept Anaesthesia, Clin Skills & Simulat Unit, Adelaide, SA 5042, Australia
关键词
cricoid pressure : airway; aspiration; Sellick; regurgitation;
D O I
10.1177/0310057X0303100406
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Cricoid pressure has been used for over 200 years. During that time, training in the technique has not changed greatly, despite the well-documented potential for complications if performed improperly. Typically, training relies on quantitative or qualitative descriptions such as "firm "pressure, a number of Newtons of force or equivalent force to that causing pain while pressing on the nose. This study tests the value of these descriptive methods in training to apply cricoid pressure. Fifty subjects were asked to apply cricoid pressure after receiving a description of the force required and again after having tested how much finger pressure on the bridge of their nose was required to cause discomfort. Initial force, force at 45 seconds, minimum force, and maximum force was recorded. The results were analysed using the Wilcoxon signed ranks test, which showed no significant difference in performance between the two types of training. One subject maintained pressure in the range of 25 to 35 Newtons for the entire 45 seconds of the first attempt but no subject performed this well on the second attempt. The use of qualitative and quantitative descriptors of the appropriate pressure does not appear useful in the training of the technique of cricoid pressure. Training incorporating force feedback is recommended.
引用
收藏
页码:388 / 391
页数:4
相关论文
共 17 条
[1]  
*AM HEART ASS INT, 2000, CIRCULATION S1, V102
[2]  
*AUSTR RES COUNC, 2001, POL STAT CRIC PRESS
[3]  
CHENEY FW, 2000, ASA NEWSLETTER JUN
[4]   A novel method of measuring cricoid force [J].
Clayton, TJ ;
Vanner, RG .
ANAESTHESIA, 2002, 57 (04) :326-329
[5]   The 50-millilitre syringe as an inexpensive training aid in the application of cricoid pressure [J].
Flucker, CJR ;
Hart, E ;
Weisz, M ;
Griffiths, R ;
Ruth, M .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2000, 17 (07) :443-447
[6]   Cricoid pressure: Teaching the recommended level [J].
Herman, NL ;
Carter, B ;
VanDecar, TK .
ANESTHESIA AND ANALGESIA, 1996, 83 (04) :859-863
[7]  
Koziol C A, 2000, AORN J, V72, P1018, DOI 10.1016/S0001-2092(06)61907-8
[8]  
LAWES EG, 1986, BRIT J ANAESTH, V52, P332
[9]   Cricoid pressure: knowledge and performance amongst anaesthetic assistants [J].
Meek, T ;
Gittins, N ;
Duggan, JE .
ANAESTHESIA, 1999, 54 (01) :59-62
[10]  
MEHROTRA D, 1979, LANCET 0915, P582