Histopatho logical evaluation of fluorescence bronchoscopy using resected lungs in cases of lung cancer

被引:33
作者
Ikeda, N
Hiyoshi, T
Kakihana, M
Honda, H
Kato, Y
Okunaka, T
Furukawa, K
Tsuchida, T
Kato, H
Ebihara, Y
机构
[1] Tokyo Med Univ, Dept Surg 1, Shinjuku Ku, Tokyo 1600023, Japan
[2] Tokyo Med Univ, Dept Pathol 2, Tokyo 1600023, Japan
关键词
D O I
10.1016/S0169-5002(03)00231-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective evaluation of the performance of autofluorescence bronchoscopy based on analysis of thin sections of the bronchus of resected Lungs was performed and compared with the results of preoperative autofluorescence bronchoscopy. Conventional bronchoscopy and autofluorescence bronchoscopy were performed prior to surgery for lung cancer. Thin sections of the bronchus were obtained from the resected specimens. The thin sections were pathologically analyzed and the diagnostic accuracy of endoscopy was calculated. The subjects were 30 consecutive operable lung cancer cases who received white light and autofluorescence bronchoscopy before operation. A total of 163 thin sections of the bronchi in the resected lungs were made. The sensitivity of white light bronchoscopy for cancer was 90 and 31% for dysplasia. The respective figures for autofluorescence bronchoscopy were 97 and 50% for cancer and dysplasia. The specificity of white light and autofluorescence was 88 and 84%, respectively. The diagnostic accuracy of autofluorescence bronchoscopy was objectively confirmed. Autofluorescence examination showed better sensitivity for cancerous/precancerous lesions and the evaluation of the extent of cancer invasion was accurate. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:303 / 309
页数:7
相关论文
共 19 条
  • [11] Localization of bronchial intraepithelial neoplastic lesions by fluorescence bronchoscopy
    Lam, S
    Kennedy, T
    Unger, M
    Miller, YE
    Gelmont, D
    Rusch, V
    Gipe, B
    Howard, D
    LeRiche, JC
    Coldman, A
    Gazdar, AF
    [J]. CHEST, 1998, 113 (03) : 696 - 702
  • [12] LASER-INDUCED FLUORESCENCE SPECTROSCOPY AT ENDOSCOPY - TISSUE OPTICS, MONTE-CARLO MODELING, AND IN-VIVO MEASUREMENTS
    QU, JN
    MACAULAY, C
    LAM, S
    PALCIC, B
    [J]. OPTICAL ENGINEERING, 1995, 34 (11) : 3334 - 3343
  • [13] Quantitative optical spectroscopy for tissue diagnosis
    RichardsKortum, R
    SevickMuraca, E
    [J]. ANNUAL REVIEW OF PHYSICAL CHEMISTRY, 1996, 47 : 555 - 606
  • [14] Occult lung cancer beyond bronchoscopic visibility in sputum-cytology positive patients
    Sato, M
    Saito, Y
    Usuda, K
    Takahashi, S
    Sagawa, M
    Fujimura, S
    [J]. LUNG CANCER, 1998, 20 (01) : 17 - 24
  • [15] BRONCHOSCOPIC TREATMENT OF LUNG-TUMORS
    SUTEDJA, G
    POSTMUS, PE
    [J]. LUNG CANCER, 1994, 11 (1-2) : 1 - 17
  • [16] THIBERVILLE L, 1995, CANCER RES, V55, P5133
  • [17] Thiberville L, 1999, EUR RESPIR J, V14, P2475
  • [18] Venmans B J, 1999, Diagn Ther Endosc, V5, P77, DOI 10.1155/DTE.5.77
  • [19] WOOLNER LB, 1983, MAYO CLIN P, V59, P435