Design of gradient coils for permanent magnets

被引:2
作者
Wang, JG [1 ]
Abele, MG [1 ]
Rusinek, H [1 ]
机构
[1] NYU,MED CTR,DEPT RADIOL,NEW YORK,NY 10016
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1996年 / 6卷 / 01期
关键词
magnetic resonance imaging; gradient coils; permanent magnets; optimization techniques;
D O I
10.1002/jmri.1880060142
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Designing gradient coils for permanent magnets requires modeling the interaction between the currents and the ferromagnetic material, We have developed and tested an iterative design approach based on the boundary element method, The power dissipated by the gradient coil is treated as a constraint of the minimization problem. The technique is illustrated on a magnet with a rectangular prismatic cavity and two ferromagnetic plates adjacent to the coil, The procedure improved the linearity of the held from 10.5% to 3.4% and reduced the power dissipation to 63% of the power of the unoptimized coil, The optimized distribution of currents has been transformed to variable locations of coil windings without loss of gradient uniformity, The new approach significantly reduces computation time and memory storage and yields practical designs of gradient coils for permanent magnets.
引用
收藏
页码:239 / 243
页数:5
相关论文
共 16 条
[1]  
Abele Manlio G., 1993, Structures of Permanent Magnets
[2]  
ABELE MG, 1994, 25 NEW YORK U DEP RA
[3]   SPECIAL-PURPOSE MRI EQUIPMENT FOR MEDICAL AND INDUSTRIAL APPLICATIONS [J].
BERTORA, FE ;
ABELE, MG .
MAGNETIC RESONANCE IMAGING, 1992, 10 (05) :809-813
[4]   A VERSATILE MAGNETIC-FIELD GRADIENT CONTROL-SYSTEM FOR NMR IMAGING [J].
BOTTOMLEY, PA .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1981, 14 (09) :1081-1087
[5]  
Fletcher R., 1981, PRACTICAL METHODS OP
[6]  
Haus H.A., 1989, ELECTROMAGNETIC FIEL
[7]   USE OF IRON-POWDER MATERIAL FOR MR-IMAGING MAGNET POLE FACES [J].
HILLCOTTINGHAM, RJ ;
EASTHAM, JF ;
YOUNG, IR .
IEEE TRANSACTIONS ON MAGNETICS, 1995, 31 (06) :4074-4076
[8]  
Mansfield P., 1982, NMR IMAGING BIOMEDIC
[9]   A DEVELOPMENT OF A PERMANENT-MAGNET ASSEMBLY FOR MRI DEVICES USING ND-FE-B MATERIAL [J].
MIYAMOTO, T ;
SAKURAI, H ;
TAKABAYASHI, H ;
AOKI, M .
IEEE TRANSACTIONS ON MAGNETICS, 1989, 25 (05) :3907-3909
[10]   STRUCTURED COILS FOR NMR APPLICATIONS [J].
PISSANETZKY, S .
IEEE TRANSACTIONS ON MAGNETICS, 1992, 28 (04) :1961-1968