Mitral valve calcium assessment: An independent predictor of balloon valvuloplasty results

被引:1
作者
Sarmiento, Ricardo A. [1 ,2 ]
Solerno, Raul [2 ]
Blanco, Rodrigo [1 ]
Giachello, Federico [2 ]
Hauqui, Agustin [2 ]
Oscos, Martin [2 ]
Blanco, Federico [1 ]
Gigena, Gerardo [1 ]
Lax, Jorge [1 ]
Pedroni, Pablo [2 ]
机构
[1] Hosp Gen Agudos Dr Cosme Argerich, Dept Intervent Cardiol, Buenos Aires, DF, Argentina
[2] Hosp Alta Complejidad Red El Cruce, Dept Intervent Cardiol, Florencio Varela, Argentina
关键词
Mitral valvuloplasty; Valve calcification; PERCUTANEOUS BALLOON; CLOSED COMMISSUROTOMY; FOLLOW-UP; VALVOTOMY; STENOSIS; CALCIFICATION; IMMEDIATE; VARIABLES; DISEASE;
D O I
10.1016/j.ihj.2019.10.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Percutaneous mitral valvuloplasty (PMV) is an effective treatment for patients with mitral valve stenosis. Echocardiographic score (ES) is a useful predictor of outcomes. However, mitral valve calcification (MVC) has been shown to predict immediate results even in patients with otherwise low ES. We sought to evaluate the usefulness of MVC assessment as a predictor of immediate and long-term outcomes after PMV. Methods: PMV was performed in 168 consecutive patients. Clinical and echocardiographic variables were analyzed. Patients were classified into 2 groups: group 1: minimal MVC and group 2: moderate to severe MVC. Primary success was defined as post-PMV mitral valve area (MVA) >= 1.5 cm(2) in the absence of major complications. Restenosis (RE) was defined as a decrease in MVA >50% of initial gain or a final MVA <1.5 cm(2). Results: Mean age was 46.5 +/- 11 years, and 86.9% (146) were women. Forty-two patients (25%) had mild MVC (group 1), and 75% of the patients had moderate to severe MVC (group 2). Procedural success was achieved in 95.2% and 76.2% for groups 1 and 2, respectively, p = 0.01. MVA after PMV was 1.82 cm(2) (IQR 25-75 = 1.60-2.00) in group 1 and 1.67 cm(2) (IQR 25-75 = 1.44-1.97) in group 2, p = 0.02. After 48 months, 28.2% of patients presented RE. Multivariate analysis identified the presence of MVC as an independent predictor of poor immediate results (HR = 0.12, 95% IC 0.03-0.91) and RE (HR = 1.94, 95% CI = 1.02-5.21). Conclusion: Our study shows that the presence of MVC may predict immediate and long-term outcomes after PMV. (c) 2019 Cardiological Society of India. Published by Elsevier B.V.
引用
收藏
页码:454 / 458
页数:5
相关论文
共 24 条
  • [1] ECHOCARDIOGRAPHIC EVALUATION OF MITRAL-VALVE STRUCTURE AND FUNCTION IN PATIENTS FOLLOWED FOR AT LEAST 6 MONTHS AFTER PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY
    ABASCAL, VM
    WILKINS, GT
    CHOONG, CY
    THOMAS, JD
    PALACIOS, IF
    BLOCK, PC
    WEYMAN, AE
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (03) : 606 - 615
  • [2] [Anonymous], 2007, PERCUTANEOUS INTERVE
  • [3] Baumgartner H, 2018, EUR HEART J, V39, P1980, DOI [10.1093/eurheartj/ehx636, 10.1093/eurheartj/ehx391]
  • [4] Percutaneous balloon versus surgical closed and open mitral commissurotomy - Seven-year follow-up results of a randomized trial
    Ben Farhat, M
    Ayari, M
    Maatouk, F
    Betbout, F
    Gamra, H
    Jarrar, M
    Tiss, M
    Hammami, S
    Thaalbi, R
    Addad, F
    [J]. CIRCULATION, 1998, 97 (03) : 245 - 250
  • [5] Echocardiographic assessment of commissural calcium: A simple predictor of outcome after percutaneous mitral balloon valvotomy
    Cannan, CR
    Nishimura, RA
    Reeder, GS
    Ilstrup, DR
    Larson, DR
    Holmes, DR
    Tajik, AJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (01) : 175 - 180
  • [6] Feasibility of percutaneous mitral commissurotomy in patients with commissural mitral valve calcification
    Dreyfus, Julien
    Cimadevilla, Claire
    Virginia Nguyen
    Brochet, Eric
    Lepage, Laurent
    Himbert, Dominique
    Iung, Bernard
    Vahanian, Alec
    Messika-Zeitoun, David
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 (24) : 1617 - 1623
  • [7] PERCUTANEOUS BALLOON MITRAL VALVOTOMY WITH THE INOUE SINGLE-BALLOON CATHETER - COMMISSURAL MORPHOLOGY AS A DETERMINANT OF OUTCOME
    FATKIN, D
    ROY, P
    MORGAN, JJ
    FENELEY, MP
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (02) : 390 - 397
  • [8] THE APPLICATION OF THE FICK PRINCIPLE TO THE MEASUREMENT OF PULMONARY BLOOD FLOW
    FRITTS, HW
    COURNAND, A
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1958, 44 (10) : 1079 - 1087
  • [9] HYDRAULIC FORMULA FOR CALCULATION OF THE AREA OF THE STENOTIC MITRAL VALVE, OTHER CARDIAC VALVES, AND CENTRAL CIRCULATORY SHUNTS .1.
    GORLIN, R
    GORLIN, SG
    [J]. AMERICAN HEART JOURNAL, 1951, 41 (01) : 1 - 29
  • [10] PREDICTORS, MECHANISMS AND OUTCOME OF SEVERE MITRAL REGURGITATION COMPLICATING PERCUTANEOUS MITRAL VALVOTOMY WITH THE INOUE BALLOON
    HERNANDEZ, R
    MACAYA, C
    BANUELOS, C
    ALFONSO, F
    GOICOLEA, J
    INIGUEZ, A
    FERNANDEZORTIZ, A
    CASTILLO, J
    ARAGONCILLO, P
    AGUADO, MG
    ZARCO, P
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (13) : 1169 - 1174