Estimation of central pulse wave velocity from radial pulse wave analysis

被引:9
|
作者
Yao, Yang [1 ,2 ]
Zhou, Shuran [2 ]
Alastruey, Jordi [3 ,4 ]
Hao, Liling [2 ]
Greenwald, Stephen E. [5 ]
Zhang, Yuelan [6 ]
Xu, Lin [1 ]
Xu, Lisheng [2 ,7 ]
Yao, Yudong [8 ]
机构
[1] ShanghaiTech Univ, Sch Informat Sci & Technol, Shanghai 201210, Peoples R China
[2] Northeastern Univ, Coll Med & Biol Informat Engn, Shenyang 110169, Liaoning, Peoples R China
[3] Kings Coll London, Dept Biomed Engn, London SE1 7EH, England
[4] Sechenov Univ, World Class Res Ctr, Digital Biodesign & Personalized Healthcare, Moscow, Russia
[5] Queen Mary Univ London, Barts & London Sch Med & Dent, Blizard Inst, London, England
[6] China Med Univ, Hosp 1, Shenyang 110122, Liaoning, Peoples R China
[7] Neusoft Res Intelligent Healthcare Technol Co Ltd, Shenyang 110169, Liaoning, Peoples R China
[8] Stevens Inst Technol, Dept Elect & Comp Engn, Hoboken, NJ 07030 USA
基金
中国国家自然科学基金;
关键词
Arterial stiffness; Pulse wave analysis; Pulse wave velocity; Wave separation analysis; EXPERT CONSENSUS DOCUMENT; ARTERIAL STIFFNESS; CARDIOVASCULAR EVENTS; TRANSIT-TIME; PRESSURE; REFLECTION; QUANTIFICATION; VALIDATION; PREDICTION; DATABASE;
D O I
10.1016/j.cmpb.2022.106781
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and Objective: Arterial stiffness, commonly assessed by carotid-femoral pulse wave velocity (cfPWV), is an independent biomarker for cardiovascular disease. The measurement of cfPWV, however, has been considered impractical for routine clinical application. Pulse wave analysis using a single pulse wave measurement in the radial artery is a convenient alternative. This study aims to identify pulse wave features for a more accurate estimation of cfPWV from a single radial pulse wave measurement. Methods: From a dataset of 140 subjects, cfPWV was measured and the radial pulse waveform was recorded for 30 s twice in succession. Features were extracted from the waveforms in the time and frequency domains, as well as by wave separation analysis. All-possible regressions with bootstrapping, McHenry's select algorithm, and support vector regression were applied to compute models for cfPWV estimation. Results: The correlation coefficients between the measured and estimated cfPWV were r = 0.81, r = 0.81, and r = 0.8 for all-possible regressions, McHenry's select algorithm, and support vector regression, respectively. The features selected by all-possible regressions are physiologically interpretable. In particular, the amplitude ratio of the diastolic peak to the notch of the radial pulse waveform (R-n,d(r,P)) is shown to be correlated with cfPWV. This correlation was further evaluated and found to be independent of wave reflections using a dataset (n = 3,325) of simulated pulse waves. Conclusions: The proposed method may serve as a convenient surrogate for the measurement of cfPWV. R-n,d(r,P) is associated with aortic pulse wave velocity and this association may not be dependent on wave reflection. (C) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Comparative study of methodologies for pulse wave velocity estimation
    P Salvi
    E Magnani
    F Valbusa
    D Agnoletti
    C Alecu
    L Joly
    A Benetos
    Journal of Human Hypertension, 2008, 22 : 669 - 677
  • [22] Comparative study of methodologies for pulse wave velocity estimation
    Salvi, P.
    Magnani, E.
    Valbusa, F.
    Agnoletti, D.
    Alecu, C.
    Joly, L.
    Benetos, A.
    JOURNAL OF HUMAN HYPERTENSION, 2008, 22 (10) : 669 - 677
  • [23] Parametric estimation of pulse arrival time: a robust approach to pulse wave velocity
    Sola, Josep
    Vetter, Rolf
    Renevey, Philippe
    Chetelat, Olivier
    Sartori, Claudio
    Rimoldi, Stefano F.
    PHYSIOLOGICAL MEASUREMENT, 2009, 30 (07) : 603 - 615
  • [24] Incorporating pulse wave velocity into model-based pulse contour analysis method for estimation of cardiac stroke volume
    Smith, Rachel
    Balmer, Joel
    Pretty, Christopher G.
    Mehta-Wilson, Tashana
    Desaive, Thomas
    Shaw, Geoffrey M.
    Chase, J. Geoffrey
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 195
  • [25] Pulse Wave Velocity is affected by the magnitude of the Pulse Wave, in human veins
    Ermini, Leonardo
    Roatta, Silvestro
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 86
  • [26] The Association Between Ankle Brachial Pressure Index and Pulse Wave Velocity: Clinical Implication of Pulse Wave Velocity
    Khandanpour, Nader
    Armon, Matthew P.
    Jennings, Barbara
    Clark, Allan
    Meyer, Felicity J.
    ANGIOLOGY, 2009, 60 (06) : 732 - 738
  • [27] Wave separation analysis-derived indexes obtained from radial and carotid tonometry in healthy pregnancy and pregnancy-associated hypertension: Comparison with pulse wave analysis-derived indexes
    Pereira, Maria M.
    Torrado, Juan
    Bock, Joshua
    Sosa, Claudio
    Diaz, Alejandro
    Bia, Daniel
    Zocalo, Yanina
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [28] The Association between Retinal and Central Pulse Wave Velocity in the Elderly
    Rezaeian, Mandieh
    Golzan, S. Mojtaba
    Avolio, Alberto P.
    Graham, Stuart
    Butlin, Mark
    ARTERY RESEARCH, 2020, 26 (03) : 148 - 153
  • [29] The Association between Retinal and Central Pulse Wave Velocity in the Elderly
    Mahdieh Rezaeian
    S. Mojtaba Golzan
    Alberto P. Avolio
    Stuart Graham
    Mark Butlin
    Artery Research, 2020, 26 : 148 - 153
  • [30] The Aortic Pulse Wave Velocity Estimation for Arterial Stiffness Assessment
    Pilt, Kristjan
    Koeoets, Kristina
    Meigas, Kalju
    Samarin, Andrei
    Zemtsovskaja, Galina
    Viigimaa, Margus
    6TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2015, 45 : 294 - 297