Corneal Biomechanical Properties in Floppy Eyelid Syndrome

被引:15
作者
Muniesa Royo, Majesus [1 ,2 ]
March de Ribot, Ana [1 ,2 ]
Sanchez-de-la-Torre, Manuel [2 ,3 ]
Huerva Escanilla, Valetin [1 ,2 ]
Jurjo Campo, Carmen [1 ,2 ]
Barbe Illa, Ferran [2 ,3 ]
机构
[1] Arnau de Vilanova Univ Hosp, Dept Ophthalmol, IRB Lleida, Lleida 25198, Catalonia, Spain
[2] Arnau de Vilanova Santa Maria Univ Hosp, Resp Dept, IRB Lleida, Lleida 25198, Catalonia, Spain
[3] Ctr Invest Biomed Red Enfermedades Resp CIBERES, Madrid, Spain
关键词
floppy eyelid syndrome; corneal biomechanical properties; corneal hysteresis; glaucoma; keratoconus; sleep apnea syndrome; OBSTRUCTIVE SLEEP-APNEA; KERATOCONUS; HYSTERESIS; PREVALENCE; THICKNESS; GLAUCOMA;
D O I
10.1097/ICO.0000000000000396
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To determine corneal biomechanical properties in patients with floppy eyelid syndrome (FES) and to compare them with eyes of controls. Methods: This case-control study included 208 eyes (72 eyes with FES and 136 without FES) of 107 patients (37 patients with FES and 70 without FES). Patients underwent a complete clinical eye examination that included corneal biomechanical evaluation carried out with the Reichert Ocular Response Analyzer. Results: Corneal hysteresis (CH), corneal resistance factor (CRF), central corneal thickness (CCT), Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated intraocular pressure (IOPcc) were evaluated. Mean CH was significantly lower in patients with FES than in those without FES (9.51 +/- 1.56 vs. 11.66 +/- 9.11; P < 0.001). These results remained statistically significant after adjusting for age and apnea-hypoapnea index (AHI) (P = 0.028). Mean CRF was 10.02 +/- 2.08 in the group of patients with FES and 11.21 +/- 5.36 in the group of patients without FES (P = 0.001). Mean IOPcc was 17.7 +/- 4.8 in patients with FES and 16.3 +/- 4.4 in those without FES (P = 0.036). After adjusting for age and AHI, these differences in CRF and IOPcc were not statistically significant (P = 0.26 and P = 0.87, respectively). No statistically significant difference was found between patients with and without FES for Goldmann-correlated intraocular pressure or CCT. Conclusions: Patients with FES had statistically lower CH values. Our findings suggest that corneal biomechanical properties could be changed in patients with FES, reflecting additional structural changes in FES.
引用
收藏
页码:521 / 524
页数:4
相关论文
共 27 条
[1]   Floppy eyelid syndrome is associated with obstructive sleep apnoea: a prospective study on 127 patients [J].
Chambe, Juliette ;
Laib, Soumia ;
Hubbard, Jeffrey ;
Erhardt, Christine ;
Ruppert, Elisabeth ;
Schroder, Carmen ;
Malan, Andre ;
Bourcier, Tristan ;
Bourgin, Patrice .
JOURNAL OF SLEEP RESEARCH, 2012, 21 (03) :308-315
[2]   Central corneal thickness and corneal hysteresis associated with glaucoma damage [J].
Congdon, NG ;
Broman, AT ;
Bandeen-Roche, K ;
Grover, D ;
Quigley, HA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) :868-875
[3]   THE FLOPPY EYELID SYNDROME [J].
CULBERTSON, WW ;
OSTLER, HB .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1981, 92 (04) :568-575
[4]  
DONNENFELD ED, 1991, OPHTHALMOLOGY, V98, P1674
[5]   Assessment of corneal biomechanical properties and their variation with age [J].
Elsheikh, Ahmed ;
Wang, Defu ;
Brown, Michael ;
Rama, Paolo ;
Campanelli, Marino ;
Pye, David .
CURRENT EYE RESEARCH, 2007, 32 (01) :11-19
[6]   The Associations of Floppy Eyelid Syndrome: A Case Control Study [J].
Ezra, Daniel G. ;
Beaconsfield, Michele ;
Sira, Mano ;
Bunce, Catey ;
Wormald, Richard ;
Collin, Richard .
OPHTHALMOLOGY, 2010, 117 (04) :831-838
[7]   Corneal Biomechanical Metrics and Anterior Segment Parameters in Mild Keratoconus [J].
Fontes, Bruno M. ;
Ambrosio, Renato, Jr. ;
Jardim, Daniela ;
Velarde, Guillermo C. ;
Nose, Walton .
OPHTHALMOLOGY, 2010, 117 (04) :673-679
[8]   Efficacy of corneal tomography parameters and biomechanical characteristic in keratoconus detection [J].
Hosseini, Seyed Mandi Ahmadi ;
Abolbashari, Fereshteh ;
Niyazmand, Harried ;
Sedaghat, Mohammad Reza .
CONTACT LENS & ANTERIOR EYE, 2014, 37 (01) :26-30
[9]   Corneal Biomechanical Properties in Normal, Forme Fruste Keratoconus, and Manifest Keratoconus After Statistical Correction for Potentially Confounding Factors [J].
Johnson, R. Duncan ;
Nguyen, Myhanh T. ;
Lee, Nancy ;
Hamilton, D. Rex .
CORNEA, 2011, 30 (05) :516-523
[10]   Factors affecting corneal hysteresis in normal eyes [J].
Kamiya, Kazutaka ;
Hagishima, Mana ;
Fujimura, Fusako ;
Shimizu, Kimiya .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 246 (10) :1491-1494