A Hybrid Active Filter for a Three-Phase 12-Pulse Diode Rectifier Used as the Front End of a Medium-Voltage Motor Drive

被引:154
作者
Akagi, Hirofumi [1 ]
Isozaki, Kohei [2 ]
机构
[1] Tokyo Inst Technol, Dept Elect & Elect Engn, Tokyo 1528552, Japan
[2] Tokyo Elect Power Co Ltd, Tokyo 1008560, Japan
关键词
Active filters; harmonic distortion; motor drives; passive filters; rectifiers; PWM INVERTER; PERFORMANCE; SYSTEM;
D O I
10.1109/TPEL.2011.2157977
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes a hybrid active filter intended for mitigating the line-side harmonic currents of a three-phase 12-pulse diode rectifier used as the front end of a medium-voltage high-power motor drive. This hybrid filter is characterized by series connection of a simple LC filter and a small-rated active filter. This circuit configuration brings low cost, small size, and light weight to the hybrid filter. Athree-phase experimental system rated at 400 V and 15 kW is designed, constructed, and tested, which is a downscaled model of the medium-voltage motor drive system. In this experiment, the LC filter is tuned to the 11th-harmonic frequency, and the active filter is based on a three-level neutral-point-clamped pulse width modulation converter (NPCPWM) with a dc capacitor voltage as low as 28 V. This hybrid filter is connected on either first or fourth winding of a line-frequency transformer with a first Delta-winding voltage of 400 V in the primary, and a second Delta-winding voltage of 220 V, a third Y-winding voltage of 220 V, and a fourth Delta-winding voltage of 400 V in the secondary. Experimental results show that the hybrid filter performs satisfactory filtering in a range from no-load to full-load conditions.
引用
收藏
页码:69 / 77
页数:9
相关论文
共 19 条
[1]   Active harmonic filters [J].
Akagi, H .
PROCEEDINGS OF THE IEEE, 2005, 93 (12) :2128-2141
[2]   INSTANTANEOUS REACTIVE POWER COMPENSATORS COMPRISING SWITCHING DEVICES WITHOUT ENERGY-STORAGE COMPONENTS [J].
AKAGI, H ;
KANAZAWA, Y ;
NABAE, A .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1984, 20 (03) :625-630
[3]  
Akagi H., 2011, IEEE T POWER ELECT, V26
[4]  
Akagi H, 2007, INSTANTANEOUS POWER
[5]   A Transformerless Hybrid Active Filter Using a Three-Level Pulsewidth Modulation (PWM) Converter for a Medium-Voltage Motor Drive [J].
Akagi, Hirofumi ;
Kondo, Ryota .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (06) :1365-1374
[6]   Voltage Balancing Control for a Three-Level Diode-Clamped Converter in a Medium-Voltage Transformerless Hybrid Active Filter [J].
Akagi, Hirofumi ;
Hatada, Takaaki .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (3-4) :571-579
[7]   A Medium-Voltage Motor Drive With a Modular Multilevel PWM Inverter [J].
Hagiwara, Makoto ;
Nishimura, Kazutoshi ;
Akagi, Hirofumi .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (07) :1786-1799
[8]   A new approach to enhance power quality for medium voltage AC drives [J].
Hammond, PW .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (01) :202-208
[9]   A 6.6-kV Transformerless Motor Drive Using a Five-Level Diode-Clamped PWM Inverter for Energy Savings of Pumps and Blowers [J].
Hatti, Natchpong ;
Hasegawa, Kazunori ;
Akagi, Hirofumi .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (3-4) :796-803
[10]   Control and performance of a fully-digital-controlled shunt active filter for installation on a power distribution system [J].
Jintakosonwit, P ;
Fujita, H ;
Akagi, H .