Trace analysis of urea nitrate by liquid chromatography-UV/fluorescence

被引:11
作者
de Perre, Chloe [1 ]
McCord, Bruce [1 ]
机构
[1] Florida Int Univ, Dept Chem & Biochem, Miami, FL 33199 USA
关键词
Urea nitrate; Explosives; Trace levels; HPLC; UV; Fluorescence;
D O I
10.1016/j.forsciint.2011.04.021
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
In this paper we have adapted a technique, previously used to determine the presence of urea in aqueous samples of wine and urine, to detect trace levels of urea nitrate explosives. The procedure involves the reaction of the uronium ion (protonated urea) with a fluorophore, xanthydrol. By modification of the procedure to utilize non-aqueous reagents, in neutral conditions, it can be made specific to the presence of the urea nitrate ion pair. The procedure includes selective detection of derivatization products by UV and fluorescence following separation by High-Performance Liquid Chromatography (HPLC). Analytical method development included optimization of HPLC conditions (solvent, gradient), UV and fluorescence wavelengths, and derivatization parameters (xanthydrol amount, reaction times, temperature). The extraction of urea nitrate from surfaces was also investigated and optimized. For best quantification, it was shown that an internal standard was required; this resulted in a quantification limit around 0.17 mM (21 mg/L). The entire procedure could be performed in less than 30 min per sample and potential interferences such as ammonium, nitrate, and urea did not produce a response under standard conditions. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:76 / 82
页数:7
相关论文
共 15 条
[1]  
Almog J, 2005, J FORENSIC SCI, V50, P582
[2]   Recovery and detection of urea nitrate in traces [J].
Almog, Joseph ;
Burda, Gila ;
Shloosh, Yael ;
Abramovich-Bar, Sara ;
Wolf, Ehud ;
Tamiri, Tsippy .
JOURNAL OF FORENSIC SCIENCES, 2007, 52 (06) :1284-1290
[3]  
BEATY J, 2008, Patent No. 2008097262
[4]   Reliable, rapid and simple voltammetric detection of urea nitrate explosive [J].
Cagan, Avi ;
Lu, Donglai ;
Cizek, Karel ;
La Belle, Jeff ;
Wang, Joseph .
ANALYST, 2008, 133 (05) :585-587
[5]  
CHANEY AL, 1962, CLIN CHEM, V8, P130
[6]   Determination of urea using high-performance liquid chromatography with fluorescence detection after automated derivatisation with xanthydrol [J].
Clark, Shona ;
Francis, Paul S. ;
Conlan, Xavier A. ;
Barnett, Neil W. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1161 (1-2) :207-213
[7]   FORENSIC ANALYSIS OF EXPLOSIVES USING ION-CHROMATOGRAPHIC METHODS [J].
MCCORD, BR ;
HARGADON, KA ;
HALL, KE ;
BURMEISTER, SG .
ANALYTICA CHIMICA ACTA, 1994, 288 (1-2) :43-56
[8]  
MILLER DR, 2010, Patent No. 2010044920
[9]   LC-MS-MS determination of stabilizers and explosives residues in hand-swabs [J].
Perret, Daniela ;
Marchese, Stefano ;
Gentili, Alessandra ;
Curini, Roberta ;
Terracciano, Alessandro ;
Bafile, Eleonora ;
Romolo, Francesco .
CHROMATOGRAPHIA, 2008, 68 (7-8) :517-524
[10]   Detection of particles of explosives via backward coherent anti-Stokes Raman spectroscopy [J].
Portnov, Alexander ;
Rosenwaks, Salman ;
Bar, Ilana .
APPLIED PHYSICS LETTERS, 2008, 93 (04)