Effects of Flow Measurement on Sloped Pipes using Ultrasonic Flowmeter

被引:0
作者
Kumar, K. [1 ]
Swain, T. K. [1 ]
Ekhande, C. S. [2 ]
Nanaware, R. M. [2 ]
机构
[1] Cent Water & Power Res Stn, Pune, Maharashtra, India
[2] PVGs Coll Engn & Technol, Pune, Maharashtra, India
来源
2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL INSTRUMENTATION AND CONTROL (ICIC) | 2015年
关键词
ultrasonic flow meter; flow measurement; pen stock; sloped pipelines; upstream and downstream straight lengths; PERFORMANCE;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Precision in flow measurement has economic consequences and also necessitates fulfillment of stipulated requirement of straight length upstream and downstream of flow meter. However, many times, the site constraints do not permit to fulfill this requirement. IEC 41(1991) recommends use of ultrasonic flow meter as a complimentary to other flow measuring techniques for hydro turbines. The motivation of the study is drawn from the typical water conductor system of hydro plants where the penstocks are generally sloped conduit in nature. The experimental investigation presented in this paper is to highlight and simulate the variation in accuracy for flow rate measurement for Reynolds number ranging from 0.8 x10(5) to 10 x10(5) with clamp-on ultrasonic flow meter with different sloped straight length considering upstream and downstream length as per the standards. The error in flow measurement by ultrasonic flow meter in straight length varied from -1.0% to +1.0% to the reference flow as per the acceptable level. Whereas, the increase of slope straight angle the percentage of shift in error is increases. The error in flow measurement of 6 degrees degree pipe line was in the range of 4.0%. Similarly, the conduit of 12 degrees degrees pipe line was up to 8%. The velocity distortion of the sloped pipes is also validated using commercial CFD Fluent solver. These findings are useful in selecting suitable location for the installation. Presently ultrasonic flow meters do not address the use at site conditions like sloped pipes. Therefore the existing ultrasonic flow metering techniques need attention for up gradation.
引用
收藏
页码:1490 / 1494
页数:5
相关论文
共 13 条
[1]  
[Anonymous], 1991, 9104BS7526 ISO
[2]  
Bates C.J., 1998, FLOMEKO 98, P411
[3]  
Delsing, 1993, P FLOMEKO93, P180
[4]  
Delsing, 1996, P FLOMEKO96, P192
[5]  
Grimley T.A., 1996, GRI010129
[6]   EFFECTS OF PULSATING FLOW ON AN ULTRASONIC GAS FLOWMETER [J].
HAKANSSON, E ;
DELSING, J .
FLOW MEASUREMENT AND INSTRUMENTATION, 1994, 5 (02) :93-101
[7]  
Hakansson E., 1992, Flow Measurement and Instrumentation, V3, P227, DOI 10.1016/0955-5986(92)90020-6
[8]  
Heritage J. E., 1989, Flow Measurement and Instrumentation, V1, P24, DOI 10.1016/0955-5986(89)90006-X
[9]  
Hojholt P., 1985, INT C FLOW MEAS NAT
[10]  
Kumar K, P 3 NAT C INN MECH E, P116