Cardiovascular responses to exercise when increasing skin temperature with narrowing of the core-to-skin temperature gradient

被引:33
作者
Chou, Ting-Heng [1 ]
Allen, Jakob R. [1 ]
Hahn, Dongwoo [1 ]
Leary, Brian K. [1 ]
Coyle, Edward F. [1 ]
机构
[1] Univ Texas Austin, Dept Kinesiol & Hlth Educ, Human Performance Lab, One Univ Stn, Austin, TX 78712 USA
关键词
cardiovascular drift; cutaneous (skin) blood flow; heart rate; hyperthermia; stroke volume; CENTRAL VENOUS PRESSURE; FOREARM BLOOD-FLOW; CARDIAC-OUTPUT; STROKE VOLUME; PROLONGED EXERCISE; BODY-TEMPERATURE; HEART-RATE; VENOMOTOR RESPONSES; THERMAL STRAIN; RAPID CHANGES;
D O I
10.1152/japplphysiol.00965.2017
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The decline in stroke volume (SV) during exercise in the heat has been attributed to either an increase in cutaneous blood flow (CBF) that reduces venous return or an increase in heart rate (HR) that reduces cardiac filling time. However, the evidence supporting each mechanism arises under experimental conditions with different skin temperatures (T-sk; e.g., >= 38 degrees C vs. <= 36 degrees C, respectively). We systematically studied cardiovascular responses to progressively increased T-sk (32 degrees C-39 degrees C) with narrowing of the core-to-skin gradient during moderate intensity exercise. Eight men cycled at 63 +/- 1% peak oxygen consumption for 20-30 min. T-sk was manipulated by having subjects wear a water-perfused suit that covered most of the body and maintained T-sk that was significantly different between trials and averaged 32.4 +/- 0.2, 35.5 +/- 0.1, 37.5 +/- 0.1, and 39.5 +/- 0.1 degrees C, respectively. The graded heating of T-sk ultimately produced a graded elevation of esophageal temperature (T-es) at the end of exercise. Incrementally increasing T-sk resulted in a graded increase in HR and a graded decrease in SV. CBF reached a similar average plateau value in all trials when T-es was above similar to 38 degrees C, independent of T-sk. T-sk had no apparent effect on forearm venous volume (FVV). In conclusion, the CBF and FVV responses suggest no further pooling of blood in the skin when T-sk is increased from 32.4 degrees C to 39.5 degrees C. The decrease in SV during moderate intensity exercise when heating the skin to high levels appears related to an increase in HR and not an increase in CBF. NEW & NOTEWORTHY This study systematically investigated the effect of increasing skin temperature (T-sk) to high levels on cardiovascular responses during moderate intensity exercise. We conclude that the declines in stroke volume were related to the increases in heart rate but not the changes in cutaneous blood flow (CBF) and forearm venous volume (FVV) during moderate intensity exercise when T-sk increased from similar to 32 degrees C to similar to 39 degrees C. High T-sk (similar to 38 degrees C) did not further elevate CBF and FVV compared with lower T-sk during moderate intensity exercise.
引用
收藏
页码:697 / 705
页数:9
相关论文
共 58 条
[1]   INFLUENCE OF TEMPERATURE ON S-A RATE OF DOGS HEART IN DENERVATED HEART-LUNG PREPARATION [J].
BADEER, H .
AMERICAN JOURNAL OF PHYSIOLOGY, 1951, 167 (01) :76-80
[2]   Relationship between cardiac output and oxygen consumption during upright cycle exercise in healthy humans [J].
Beck, Kenneth C. ;
Randolph, Lakesha N. ;
Bailey, Kent R. ;
Wood, Christina M. ;
Snyder, Eric M. ;
Johnson, Bruce D. .
JOURNAL OF APPLIED PHYSIOLOGY, 2006, 101 (05) :1474-1480
[3]   CHANGES IN CARDIAC OUTPUT, STROKE VOLUME, AND CENTRAL VENOUS PRESSURE INDUCED BY ATROPINE IN MAN [J].
BERRY, JN ;
THOMPSON, HK ;
MILLER, DE .
AMERICAN HEART JOURNAL, 1959, 58 (02) :204-213
[4]   CHANGES IN TONE OF LIMB VEINS DURING SUPINE EXERCISE [J].
BEVEGARD, BS ;
SHEPHERD, JT .
JOURNAL OF APPLIED PHYSIOLOGY, 1965, 20 (01) :1-&
[5]   REACTION IN MAN OF RESISTANCE AND CAPACITY VESSELS IN FOREARM AND HAND TO LEG EXERCISE [J].
BEVEGARD, BS ;
SHEPHERD, JT .
JOURNAL OF APPLIED PHYSIOLOGY, 1966, 21 (01) :123-&
[6]  
BEVEGARD S, 1962, ACTA MED SCAND, V172, P615
[7]  
BEVEGARD STURE, 1963, ACTA PHYSIOL SCAND, V57, P61
[8]  
BEVEGARD STURE, 1967, CARDIOVASC RES, V1, P21, DOI 10.1093/cvr/1.1.21
[9]   INFLUENCE OF TEMPERATURE AND ADRENERGIC-STIMULATION ON RAT SINOATRIAL FREQUENCY [J].
BOLTER, CP ;
ATKINSON, KJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 254 (05) :R840-R844
[10]  
Borg G., 1976, PHYS WORK EFFORT, P39