Frame-based stereotactic biopsy of canine brain masses: technique and clinical results in 26 cases

被引:37
作者
Rossmeisl, John Henry [1 ,2 ,3 ]
Andriani, Rudy T. [1 ,2 ]
Cecere, Thomas E. [4 ]
Lahmers, Kevin [4 ]
LeRoith, Tanya [4 ]
Zimmerman, Kurt L. [4 ]
Gibo, Denise [3 ]
Debinski, Waldemar [3 ]
机构
[1] Virginia Tech, Dept Small Anim Clin Sci, Vet & Comparat Neuro Oncol Lab, Virginia Maryland Coll Vet Med, Blacksburg, VA USA
[2] Virginia Tech, Dept Mech Engn, Virginia Tech Wake Forest Sch Biomed Engn, Blacksburg, VA USA
[3] Wake Forest Univ, Comprehens Canc Ctr, Brain Tumor Ctr Excellence, Sch Med, Winston Salem, NC 27101 USA
[4] Virginia Tech, Virginia Maryland Coll Vet Med, Dept Biomed Sci & Pathobiol, Blacksburg, VA USA
关键词
brain tumor; dog; glioma; neurooncology; neurosurgery; DIAGNOSTIC YIELD; SYSTEM; DEVICE; TUMORS; SAFETY; DOGS; PLACEMENT; ACCURACY; EFFICACY;
D O I
10.3389/fvets.2015.00020
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
This report describes the methodology, diagnostic yield, and adverse events (AE) associated with frame-based stereotactic brain biopsies (FBSB) obtained from 26 dogs with solitary forebrain lesions. Medical records were reviewed from dogs that underwent FBSB using two stereotactic headframes designed for use in small animals and compatible with computed tomographic (CT) and magnetic resonance (MR) imaging. Stereotactic plans were generated from MR and CT images using commercial software, and FBSB performed both with (14/26) and without intraoperative image guidance. Records were reviewed for diagnostic yield, defined as the proportion of biopsies producing a specific neuropathological diagnosis, AE associated with FBSB, and risk factors for the development of AE. Postprocedural AE were evaluated in 19/26 dogs that did not proceed to a therapeutic intervention immediately following biopsy. Biopsy targets included intra-axial telencephalic masses (24/26), one intra-axial diencephalic mass, and one extra-axial parasellar mass. The median target volume was 1.99 cm(3). No differences in patient, lesion, or outcome variables were observed between the two headframe systems used or between FBSB performed with or without intraoperative CT guidance. The diagnostic yield of FBSB was 94.6%. Needle placement error was a significant risk factor associated with procurement of non-diagnostic biopsy specimens. Gliomas were diagnosed in 24/26 dogs, and meningioma and granulomatous meningoencephalitis in 1 dog each. AE directly related to FBSB were observed in a total of 7/26 (27%) of dogs. Biopsy-associated clinical morbidity, manifesting as seizures and transient neurological deterioration, occurred in 3/19 (16%) of dogs. The case fatality rate was 5.2% (1/19 dogs), with death attributable to intracranial hemorrhage. FBSB using the described apparatus was relatively safe and effective at providing neuropathological diagnoses in dogs with focal forebrain lesions.
引用
收藏
页数:13
相关论文
共 40 条
[1]  
Adamo F., 2005, J VET INT MED, V19, P420, DOI [10.1111/j.1939-1676.2005.tb02714.x, DOI 10.1111/J.1939-1676.2005.TB02714.X]
[2]  
[Anonymous], 1906, BRIT MED J, V1906, P1799
[3]  
ASTM, 2013, F211907 ASTM
[4]   COMPARATIVE MAGNETIC RESONANCE IMAGING FINDINGS BETWEEN GLIOMAS AND PRESUMED CEREBROVASCULAR ACCIDENTS IN DOGS [J].
Cervera, Vicente ;
Mai, Wilfried ;
Vite, Charles H. ;
Johnson, Victoria ;
Dayrell-Hart, Betsy ;
Seiler, Gabriela S. .
VETERINARY RADIOLOGY & ULTRASOUND, 2011, 52 (01) :33-40
[5]   DESCRIPTION AND VALIDATION OF A MAGNETIC RESONANCE IMAGING-GUIDED STEREOTACTIC BRAIN BIOPSY DEVICE IN THE DOG [J].
Chen, Annie V. ;
Wininger, Fred A. ;
Frey, Stephen ;
Comeau, Roch M. ;
Bagley, Rodney S. ;
Tucker, Russell L. ;
Schneider, Adam R. ;
Gay, John M. .
VETERINARY RADIOLOGY & ULTRASOUND, 2012, 53 (02) :150-156
[6]   Stereotactic brain biopsy: Single center retrospective analysis of complications [J].
Chen, Ching-Chang ;
Hsu, Peng-Wei ;
Wu, Tai-Wei Erich ;
Lee, Shih-Tseng ;
Chang, Chen-Nen ;
Wei, Kuo-chen ;
Chuang, Chih-Cheng ;
Wu, Chieh-Tsai ;
Lui, Tai-Ngar ;
Hsu, Yung-Hsin ;
Lin, Tzu-Kang ;
Lee, Sai-Cheung ;
Huang, Yin-Cheng .
CLINICAL NEUROLOGY AND NEUROSURGERY, 2009, 111 (10) :835-839
[7]  
COFFEY RJ, 1987, APPL NEUROPHYSIOL, V50, P81
[8]   Safety and efficacy of frameless and frame-based intracranial biopsy techniques [J].
Dammers, R. ;
Haitsma, I. K. ;
Schouten, J. W. ;
Kros, J. M. ;
Avezaat, C. J. J. ;
Vincent, A. J. P. E. .
ACTA NEUROCHIRURGICA, 2008, 150 (01) :23-29
[9]   New Agents for Targeting of IL-13RA2 Expressed in Primary Human and Canine Brain Tumors [J].
Debinski, Waldemar ;
Dickinson, Peter ;
Rossmeisl, John H. ;
Robertson, John ;
Gibo, Denise M. .
PLOS ONE, 2013, 8 (10)
[10]   Canine model of convection-enhanced delivery of liposomes containing CPT-11 monitored with real-time magnetic resonance imaging [J].
Dickinson, Peter J. ;
LeCouteur, Richard A. ;
Higgins, Robert J. ;
Bringas, John R. ;
Roberts, Byron ;
Larson, Richard F. ;
Yamashita, Yoji ;
Krauze, Michal ;
Noble, Charles O. ;
Drummond, Daryl ;
Kirpotin, Dmitri B. ;
Park, John W. ;
Berger, Mitchel S. ;
Bankiewicz, Krystof S. .
JOURNAL OF NEUROSURGERY, 2008, 108 (05) :989-998