Radiation dose of fluoroscopy-guided versus ultralow-dose CT-fluoroscopy-guided lumbar spine epidural steroid injections

被引:5
作者
Wieschhoff, Ged G. [1 ]
Miskin, Nityanand P. [1 ]
Kim, Jeom Soon [1 ]
Hamberg, Leena M. [1 ]
Mandell, Jacob C. [1 ]
机构
[1] Brigham & Womens Hosp, Dept Radiol, 75 Francis St, Boston, MA 02115 USA
关键词
Epidural steroid injection (ESI); Fluoroscopy; CT-fluoroscopy; PAIN; BACK; REDUCTION; EXPOSURE; PATIENT;
D O I
10.1007/s00256-021-03920-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Compare radiation dose of lumbar spine epidural steroid injections (ESIs) performed under fluoroscopy guidance and ultralow-dose CT-fluoroscopy guidance. Materials and methods Retrospective review of consecutive lumbar ESIs performed using fluoroscopy, between May 2017 and April 2019, and using ultralow-dose CT-fluoroscopy, between August 2019 and February 2021, was performed. Ultralow-dose CT-fluoroscopy technique omits a planning CT scan, utilizes CT-fluoroscopy, and minimizes radiation dose parameters. Patient characteristics (age, sex, height, weight, body mass index (BMI)), procedural characteristics (anatomic level, type of ESI, procedure time, pain reduction, complications, trainee participation), and radiation dose were compared. Chi-square tests and two-sample t-tests were performed for statistical analysis. Results One hundred and forty-seven patients (mean age 55.8 +/- 16.7; 85 women) underwent ESIs using fluoroscopy. Sixty-six patients (mean age 60.9 +/- 16.7; 33 women) underwent ESIs using ultralow-dose CT-fluoroscopy. The effective dose for the fluoroscopy group was 0.30 mSv +/- 0.34, compared to 0.15 mSV +/- 0.11 for ultralow-dose CT-fluoroscopy (p < 0.001). The average age in the CT-fluoroscopy group was older (p = 0.04), and there was more trainee participation in the fluoroscopy group (p < 0.001); otherwise there was no statistically significant difference in patient or procedural characteristics between the conventional fluoroscopy group and the ultralow-dose CT-fluoroscopy group. There was no statistically significant difference in immediate post-procedure pain reduction between the groups (p = 0.16). Four intrathecal injections occurred only in the fluoroscopy group, though this difference was not significant (p = 0.18). Conclusion Ultralow-dose CT-fluoroscopy technique for image-guided lumbar spine ESIs can lower radiation dose compared to fluoroscopy-guided technique.
引用
收藏
页码:1055 / 1062
页数:8
相关论文
共 30 条
  • [1] Reducing Patient Radiation Exposure From CT Fluoroscopy-Guided Lumbar Spine Pain Injections by Targeting the Planning CT
    Amrhein, Timothy J.
    Schauberger, J. Scott
    Kranz, Peter G.
    Hoang, Jenny K.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (02) : 390 - 394
  • [2] Radiation dose reduction in CT-guided periradicular injections in lumbar spine: Feasibility of a new institutional protocol for improved patient safety
    Juraj Artner
    Balkan Cakir
    Sebastian Weckbach
    Heiko Reichel
    Friederike Lattig
    [J]. Patient Safety in Surgery, 6 (1)
  • [3] Effective radiation dose reduction in computed tomography-guided spinal injections: a prospective, comparative study with technical considerations
    Artner, Juraj
    Lattig, Friederike
    Reichel, Heiko
    Cakir, Balkan
    [J]. ORTHOPEDIC REVIEWS, 2012, 4 (02) : 109 - 112
  • [4] Chang A, 2011, AJNR Am J Neuroradiol, V32, pE175, DOI 10.3174/ajnr.A2316
  • [5] Radiation Dose for 345 CT-Guided Interlaminar Lumbar Epidural Steroid Injections
    Chang, A. L.
    Schoenfeld, A. H.
    Brook, A. L.
    Miller, T. S.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (10) : 1882 - 1886
  • [6] Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product
    Deak, Paul D.
    Smal, Yulia
    Kalender, Willi A.
    [J]. RADIOLOGY, 2010, 257 (01) : 158 - 166
  • [7] PERCUTANEOUS NEEDLE-BIOPSY OF BONE IN CANCER PATIENT
    DESANTOS, LA
    LUKEMAN, JM
    WALLACE, S
    MURRAY, JA
    AYALA, AG
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1978, 130 (04) : 641 - 649
  • [8] Fluoroscopy-guided versus CT-guided Lumbar Steroid Injections: Comparison of Radiation Exposure and Outcomes
    Dietrich, Tobias J.
    Peterson, Cynthia K.
    Zeimpekis, Konstantinos G.
    Bensler, Susanne
    Sutter, Reto
    Pfirrmann, Christian W. A.
    [J]. RADIOLOGY, 2019, 290 (03) : 752 - 759
  • [9] EPIDURAL STEROID INJECTION - A PROCEDURE IDEALLY PERFORMED WITH FLUOROSCOPIC CONTROL
    ELKHOURY, GY
    EHARA, S
    WEINSTEIN, JN
    MONTGOMERY, WJ
    KATHOL, MH
    [J]. RADIOLOGY, 1988, 168 (02) : 554 - 557
  • [10] Ultra-low-dose periradicular infiltration of the lumbar spine: spot scanning and its potential for further dose reduction by replacing helical planning CT
    Elsholtz, Fabian Henry Juergen
    Schaafs, Lars-Arne
    Erxleben, Christoph
    Hamm, Bernd
    Niehues, Stefan Markus
    [J]. RADIOLOGIA MEDICA, 2017, 122 (09): : 705 - 712