Precise and accurate determination of calcium isotope ratios in urine using HR-ICP-SFMS

被引:29
|
作者
Field, MP
Shapses, S
Cifuentes, M
Sherrell, RM
机构
[1] Rutgers State Univ, Inst Marine & Coastal Sci, New Brunswick, NJ 08901 USA
[2] Rutgers State Univ, Dept Nutr Sci, New Brunswick, NJ 08901 USA
关键词
D O I
10.1039/b301703f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Precise and accurate determination of calcium isotope ratios in urine is imperative in limiting the expense of enriched isotopes used in human metabolic tracer studies. The calcium isotope spectrum obtained from an ICP-MS ( using conventional spray chamber), operated in low resolution mode (LR = 300), is subject to numerous polyatomic, isobaric and doubly charged interferences. The most severe polyatomic interfences can be resolved at resolutions greater than 3500, whereas, isobaric and doubly charged interferences are easily corrected. Precise (<0.1% 1σ) isotope ratios, however, are not routinely obtained in medium resolution (MR = 4300). Here we use a HR-ICP-MS in MR to identify and determine methods to reduce polyatomic interferences. Using oxalate precipitation of urinary calcium and desolvation sample introduction, interferences can be reduced sufficiently to allow determination of the 42, 43, 44, 46 and 48 isotopes of calcium with the precision of LR. Isotope ratio precision and accuracy is < +/-0.1% (1sigma) for analysis of three isotopes (42, 43, and 44), as required for clinical studies. Propagating this level of uncertainty indicates that >4% enrichments provide < +/-10% (2σ) uncertainty in the calculated fractional calcium absorption values. Minimizing unnecessary enrichments can increase the number of subjects in studies without increasing the substantial cost of enriched isotopes. This new analytical method is applied to our on-going clinical trials where 0.017 mg kg(-1) of Ca-42 (90.8%; intravenous, IV) and 0.012 mg kg(-1) Ca-43 (52.1%; oral) administered to postmenopausal women show average 24 h (pooled) urinary enrichments of 5.0% and 5.1% from the intravenous and oral doses, respectively.
引用
收藏
页码:727 / 733
页数:7
相关论文
共 50 条
  • [21] In situ precise determination of stable Mo isotope ratios in molybdenite by femtosecond LA-MC-ICP-MS
    Tian, Jing
    Bao, Zhian
    Chen, Kaiyun
    Zong, Chunlei
    Zhang, Yan
    Peng, Deyi
    Yuan, Honglin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (08) : 2021 - 2029
  • [22] In situ precise determination of stable Mo isotope ratios in molybdenite by femtosecond LA-MC-ICP-MS
    Tian, Jing
    Bao, Zhian
    Chen, Kaiyun
    Zong, Chunlei
    Zhang, Yan
    Peng, Deyi
    Yuan, Honglin
    Journal of Analytical Atomic Spectrometry, 1600, 39 (08): : 2021 - 2029
  • [23] Accurate and precise determination of the boron isotope ratio by QQQ-ICP-MS: application to natural waters and carbonates
    Chanakya, I. V. Satya
    Misra, Sambuddha
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (06) : 1327 - 1339
  • [24] Accurate and precise determination of stable Cr isotope compositions in carbonates by double spike MC-ICP-MS
    Bonnand, Pierre
    Parkinson, Ian J.
    James, Rachael H.
    Karjalainen, Anne-Mari
    Fehr, Manuela A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (03) : 528 - 535
  • [25] Alternative data reduction for precise and accurate isotope ratio determination via LA-MC-ICP-MS
    Fietzke, J.
    Liebetrau, V.
    Guenther, D.
    Frische, A.
    Zumholz, K.
    Hansteen, T. H.
    Eisenhauer, A.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A267 - A267
  • [26] Determination of Ca isotope ratios in metabolic studies using sector field inductively coupled plasma mass spectrometer (HR-ICP-MS)
    Field, MP
    Cifuentes, M
    Sherrell, RM
    Shapses, SA
    BONE, 2001, 28 (05) : S173 - S173
  • [27] Determination of total uranium and uranium isotope ratios in human urine by ICP-MS: results of an interlaboratory study
    Arnason, John G.
    Pellegri, Christine N.
    Parsons, Patrick J.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (01) : 126 - 138
  • [28] Precise and Accurate In Situ Determination of Lead Isotope Ratios in NIST, USGS, MPI-DING and CGSG Glass Reference Materials using Femtosecond Laser Ablation MC-ICP-MS
    Chen Kaiyun
    Yuan Honglin
    Bao Zhian
    Zong Chunlei
    Dai Mengning
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2014, 38 (01) : 5 - 21
  • [29] A Highly Efficient Method for the Accurate and Precise Determination of Zinc Isotopic Ratios in Zinc-rich Minerals Using MC-ICP-MS
    Nie, Xiaojuan
    Bao, Zhian
    Liang, Peng
    Chen, Kaiyun
    Zong, Chunlei
    Yuan, Honglin
    ATOMIC SPECTROSCOPY, 2022, 43 (02) : 117 - 125