Precise and accurate determination of calcium isotope ratios in urine using HR-ICP-SFMS

被引:29
|
作者
Field, MP
Shapses, S
Cifuentes, M
Sherrell, RM
机构
[1] Rutgers State Univ, Inst Marine & Coastal Sci, New Brunswick, NJ 08901 USA
[2] Rutgers State Univ, Dept Nutr Sci, New Brunswick, NJ 08901 USA
关键词
D O I
10.1039/b301703f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Precise and accurate determination of calcium isotope ratios in urine is imperative in limiting the expense of enriched isotopes used in human metabolic tracer studies. The calcium isotope spectrum obtained from an ICP-MS ( using conventional spray chamber), operated in low resolution mode (LR = 300), is subject to numerous polyatomic, isobaric and doubly charged interferences. The most severe polyatomic interfences can be resolved at resolutions greater than 3500, whereas, isobaric and doubly charged interferences are easily corrected. Precise (<0.1% 1σ) isotope ratios, however, are not routinely obtained in medium resolution (MR = 4300). Here we use a HR-ICP-MS in MR to identify and determine methods to reduce polyatomic interferences. Using oxalate precipitation of urinary calcium and desolvation sample introduction, interferences can be reduced sufficiently to allow determination of the 42, 43, 44, 46 and 48 isotopes of calcium with the precision of LR. Isotope ratio precision and accuracy is < +/-0.1% (1sigma) for analysis of three isotopes (42, 43, and 44), as required for clinical studies. Propagating this level of uncertainty indicates that >4% enrichments provide < +/-10% (2σ) uncertainty in the calculated fractional calcium absorption values. Minimizing unnecessary enrichments can increase the number of subjects in studies without increasing the substantial cost of enriched isotopes. This new analytical method is applied to our on-going clinical trials where 0.017 mg kg(-1) of Ca-42 (90.8%; intravenous, IV) and 0.012 mg kg(-1) Ca-43 (52.1%; oral) administered to postmenopausal women show average 24 h (pooled) urinary enrichments of 5.0% and 5.1% from the intravenous and oral doses, respectively.
引用
收藏
页码:727 / 733
页数:7
相关论文
共 50 条
  • [1] Precise and accurate determination of calcium isotope ratios in urine using HR-ICP-SFMS
    Field, M.P. (field@imcs.rutgers.edu), 1600, Royal Society of Chemistry (18):
  • [2] Precise and accurate determination of lead isotope ratios in mining wastes by ICP-QMS as a tool to identify their source
    Margui, E.
    Iglesias, M.
    Queralt, I.
    Hidalgo, M.
    TALANTA, 2007, 73 (04) : 700 - 709
  • [3] ACCURATE AND PRECISE DETERMINATION OF ISOTOPIC RATIOS BY MC-ICP-MS: A REVIEW
    Yang, Lu
    MASS SPECTROMETRY REVIEWS, 2009, 28 (06) : 990 - 1011
  • [4] Novel metallomic profiling and non-carcinogenic risk assessment of botanical ingredients for use in herbal, phytopharmaceutical and dietary products using HR-ICP-SFMS
    Ciara-Ruth Kenny
    Gavin Ring
    Aisling Sheehan
    Michael A. P. Mc Auliffe
    Brigid Lucey
    Ambrose Furey
    Scientific Reports, 12
  • [5] Novel metallomic profiling and non-carcinogenic risk assessment of botanical ingredients for use in herbal, phytopharmaceutical and dietary products using HR-ICP-SFMS
    Kenny, Ciara-Ruth
    Ring, Gavin
    Sheehan, Aisling
    Mc Auliffe, Michael A. P.
    Lucey, Brigid
    Furey, Ambrose
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [6] Precise Determination of Isotope Ratios in Nuclear Samples by CE-MC-ICP-MS
    Dupuis, Erwan
    Isnard, Helene
    Chartier, Frederic
    30TH INTERNATIONAL CONFERENCE NUCLEAR ENERGY FOR NEW EUROPE (NENE 2021), 2021,
  • [7] Stable isotope labelling and FPLC-ICP-SFMS for the accurate determination of clinical iron status parameters in human serum
    Busto, M. Estela del Castillo
    Montes-Bayon, Maria
    Bettmer, Joerg
    Sanz-Medel, Alfredo
    ANALYST, 2008, 133 (03) : 379 - 384
  • [8] DOUBLE SPIKING FOR PRECISE DETERMINATION OF CALCIUM ISOTOPE RATIOS BY MASS-SPECTROMETRY
    COLEMAN, ML
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1972, 53 (04): : 544 - &
  • [9] Accurate and precise microscale measurements of boron isotope ratios in calcium carbonates using laser ablation multicollector-ICPMS
    Sadekov, Aleksey
    Lloyd, Nicholas S.
    Misra, Sambuddha
    Trotter, Julie
    D'Olivo, Juan
    McCulloch, Malcolm
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (03) : 550 - 560
  • [10] Precise and accurate determination of boron isotope ratios by multiple collector ICP-MS: origin of boron in the Ngawha geothermal system, New Zealand
    Aggarwal, JK
    Sheppard, D
    Mezger, K
    Pernicka, E
    CHEMICAL GEOLOGY, 2003, 199 (3-4) : 331 - 342