Impact of aperturing and pixel size on XPCS using AGIPD

被引:3
作者
Becker, J. [1 ]
Graafsma, H. [1 ]
机构
[1] DESY, D-22607 Hamburg, Germany
关键词
X-ray detectors; Simulation methods and programs; Instrumentation for FEL; Detector modelling and simulations I (interaction of radiation with matter; interaction of photons with matter; interaction of hadrons with matter; etc); NEUTRON-SCATTERING; DETECTOR;
D O I
10.1088/1748-0221/7/02/C02064
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A case study for the Adaptive Gain Integrating Pixel Detector (AGIPD) at the European XFEL employing the intensity autocorrelation technique was performed using the detector simulation tool HORUS. The study compares the AGIPD (pixel size of (200 mu m)(2)) to a possible apertured version of the detector and to a hypothetical system with 100 mu m pixel size and investigates the influence of intensity fluctuations and incoherent noise on the quality of the acquired data.
引用
收藏
页数:10
相关论文
共 14 条
[1]  
Altarelli M., 2006, The European X-Ray Free-Electron Laser Technical Design Report
[2]   Simulation study of the impact of AGIPD design choices on X-ray Photon Correlation Spectroscopy utilizing the intensity autocorrelation technique [J].
Becker, J. ;
Gutt, C. ;
Graafsma, H. .
JOURNAL OF INSTRUMENTATION, 2011, 6
[3]  
Becker J., 2010, THESIS HAMBURG U
[4]   Impact of plasma effects on the performance of silicon sensors at an X-ray FEL [J].
Becker, Julian ;
Eckstein, Doris ;
Klanner, Robert ;
Steinbrueck, Georg .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 615 (02) :230-236
[5]   NEUTRON SCATTERING FROM A LIQUID ON A JUMP DIFFUSION MODEL [J].
CHUDLEY, CT ;
ELLIOTT, RJ .
PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON, 1961, 77 (494) :353-&
[6]   Dynamics of n-butane-methane mixtures in silicalite, using quasielastic neutron scattering and molecular dynamics simulations [J].
Gergidis, LN ;
Theodorou, DN ;
Jobic, H .
JOURNAL OF PHYSICAL CHEMISTRY B, 2000, 104 (23) :5541-5552
[7]   Correlation spectroscopy with coherent X-rays [J].
Grübel, G ;
Zontone, F .
JOURNAL OF ALLOYS AND COMPOUNDS, 2004, 362 (1-2) :3-11
[8]   The adaptive gain integrating pixel detector AGIPD a detector for the European XFEL [J].
Henrich, B. ;
Becker, J. ;
Dinapoli, R. ;
Goettlicher, P. ;
Graafsma, H. ;
Hirsemann, H. ;
Klanner, R. ;
Krueger, H. ;
Mazzocco, R. ;
Mozzanica, A. ;
Perrey, H. ;
Potdevin, G. ;
Schmitt, B. ;
Shi, X. ;
Srivastava, A. K. ;
Trunk, U. ;
Youngman, C. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 :S11-S14
[9]   Simulated performance of high-Z detectors with Medipix3 readout [J].
Pennicard, D. ;
Graafsma, H. .
JOURNAL OF INSTRUMENTATION, 2011, 6
[10]   Simulations of charge summing and threshold dispersion effects in Medipix3 [J].
Pennicard, D. ;
Ballabriga, R. ;
Llopart, X. ;
Campbell, M. ;
Graafsma, H. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 636 (01) :74-81