Prompt-gamma monitoring in hadrontherapy: A review

被引:206
作者
Krimmer, J. [1 ]
Dauvergne, D. [2 ]
Letang, J. M. [3 ]
Testa, E. [1 ]
机构
[1] Univ Lyon 1, CNRS, IN2P3, Univ Lyon,UMR5822,IPNL, F-69622 Villeurbanne, France
[2] Univ Grenoble Alpes, CNRS, IN2P3, UMR5821,LPSC, F-38026 Grenoble, France
[3] Univ Claude Bernard Lyon 1, Univ Lyon, UJM St Etienne,UMR 5220, CNRS,INSERM,Ctr Leon Berard,CREATIS,INSA Lyon,U12, F-69373 Lyon, France
关键词
Particle therapy; Hadrontherapy; Prompt-gamma; Proton therapy; Gamma camera; ION-BEAM THERAPY; PROTON RANGE VERIFICATION; POSITRON EMITTER DISTRIBUTIONS; COMPTON CAMERA; RAY EMISSION; PENCIL BEAMS; CLINICAL-APPLICATION; DOSE VERIFICATION; PET VERIFICATION; IMAGING-SYSTEM;
D O I
10.1016/j.nima.2017.07.063
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Secondary radiation emission induced by nuclear reactions is correlated to the path of ions in matter. Therefore, such penetrating radiation can be used for in vivo control of hadrontherapy treatments, for which the primary beam is absorbed inside the patient. Among secondary radiations, prompt-gamma rays were proposed for realtime verification of ion range. Such a verification is a desired condition to reduce uncertainties in treatment planning. For more than a decade, efforts have been undertaken worldwide to promote prompt-gamma-based devices to be used in clinical conditions. Dedicated cameras are necessary to overcome the challenges of a broad- and high-energy distribution, a large background, high instantaneous count rates, and compatibility constraints with patient irradiation. Several types of prompt-gamma imaging devices have been proposed, that are either physically-collimated or electronically collimated (Compton cameras). Clinical tests are now undergoing. Meanwhile, other methods than direct prompt-gamma imaging were proposed, that are based on specific counting using either time-of-flight or photon energy measurements. In the present article, we make a review and discuss the state of the art for all techniques using prompt-gamma detection to improve the quality assurance in hadrontherapy. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:58 / 73
页数:16
相关论文
共 171 条
[1]  
Abellan C, 2013, P 33 INT C ADV NUCL, P1, DOI DOI 10.1109/ANIMMA.2013.6728028
[2]   Precise measurement of prompt photon emission from 80 MeV/u carbon ion beam irradiation (vol 7, P03001, 2012) [J].
Agodi, C. ;
Bellini, F. ;
Cirrone, G. A. P. ;
Collamati, F. ;
Cuttone, G. ;
De Lucia, E. ;
De Napoli, M. ;
Di Domenico, A. ;
Faccini, R. ;
Ferroni, F. ;
Fiore, S. ;
Gauzzi, P. ;
Iarocci, E. ;
Marafini, M. ;
Mattei, I. ;
Paoloni, A. ;
Patera, V. ;
Piersanti, L. ;
Romano, F. ;
Sarti, A. ;
Sciubba, A. ;
Voena, C. .
JOURNAL OF INSTRUMENTATION, 2013, 8
[3]   Precise measurement of prompt photon emission from 80 MeV/u carbon ion beam irradiation [J].
Agodi, C. ;
Bellini, F. ;
Cirrone, G. A. P. ;
Collamati, F. ;
Cuttone, G. ;
De Lucia, E. ;
De Napoli, M. ;
Di Domenico, A. ;
Faccini, R. ;
Ferroni, F. ;
Fiore, S. ;
Gauzzi, P. ;
Iarocci, E. ;
Marafini, M. ;
Mattei, I. ;
Paoloni, A. ;
Patera, V. ;
Piersanti, L. ;
Romano, F. ;
Sarti, A. ;
Sciubba, A. ;
Voena, C. .
JOURNAL OF INSTRUMENTATION, 2012, 7
[4]  
Amaldi G. Magrin, 2013, LANDOLT BORNSTEIN GR, P488
[5]   Accelerators for hadrontherapy: From Lawrence cyclotrons to linacs [J].
Amaldi, U. ;
Bonomi, R. ;
Braccini, S. ;
Crescenti, M. ;
Degiovanni, A. ;
Garlasche, M. ;
Garonna, A. ;
Magrin, G. ;
Mellace, C. ;
Pearce, P. ;
Pitta, G. ;
Puggioni, P. ;
Rosso, E. ;
Andres, S. Verdu ;
Wegner, R. ;
Weiss, M. ;
Zennaro, R. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 620 (2-3) :563-577
[6]   Resolution recovery for Compton camera using origin ensemble algorithm [J].
Andreyev, A. ;
Celler, A. ;
Ozsahin, I. ;
Sitek, A. .
MEDICAL PHYSICS, 2016, 43 (08) :4866-4876
[7]  
[Anonymous], [No title captured]
[8]  
[Anonymous], 2016, THESIS
[9]  
[Anonymous], 2001, MED PHYS, V28, P861
[10]  
[Anonymous], 2013, NUCL SCI S MED IM C