Hydrogel Sealant for Closure of Clear Corneal Incisions in Combined Glaucoma Procedures

被引:1
作者
Machiele, Ryan D. [1 ]
Guduru, Abhilash [2 ]
Herndon, Leon W. [2 ]
机构
[1] Univ N Carolina, Dept Ophthalmol, Chapel Hill, NC USA
[2] Duke Univ, Dept Ophthalmol, Med Ctr, 2351 Erwin Rd, Durham, NC 27705 USA
来源
CLINICAL OPHTHALMOLOGY | 2022年 / 16卷
关键词
ophthalmic; glue; suture; leak; MIGS; endophthalmitis; CATARACT-SURGERY; ENDOPHTHALMITIS;
D O I
10.2147/OPTH.S354531
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The purpose of this study is to determine whether ReSure hydrogel sealant is superior to standard suture for closure of clear corneal incisions in the setting of combined glaucoma procedures. Setting: Glaucoma Department, Duke University Eye Center. Design: This is a retrospective case series. Subjects studied were patients in a 6-year period undergoing combined phacoemulsification and glaucoma surgery. All cases were performed by the same surgeon. Wound closure methods correlated with discrete timeframes, as ReSure replaced suture midway through the study period, thereby establishing sutured closure as an analogous control group. Methods: All cases included a phacoemulsification procedure requiring a 2.4 mm clear corneal incision. Upon completion of the phacoemulsification portion of the case, the wound was closed with either ReSure hydrogel or standard 10-0 suture closure. The researchers assessed the rate of Seidel-positive corneal wound leak on postoperative day one. Results: In all cases employing ReSure, no wound leak was observed at postoperative day one. Within the suture group, 3 cases showed Seidel positivity of the corneal incision. This equates to a statistically significant difference in wound leak frequency of 2.04% (P = 0.012); confidence interval, 0.21 to 5.82. Conclusion: ReSure was able to maintain closure 100% of the time over hundreds of combined cases. Suture, though the standard of practice, did not perform to this level, presenting with 3 cases of spontaneous wound leak. We conclude that ReSure is highly effective and superior to suture in closure of clear corneal incisions in combined glaucoma procedures.
引用
收藏
页码:861 / 865
页数:5
相关论文
共 15 条
  • [1] Evaluation of eye drop administration by inexperienced patients after cataract surgery
    An, Jella Angela
    Kasner, Oscar
    Samek, Deborah Anne
    Levesque, Valerie
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (11) : 1857 - 1861
  • [2] New options for combined cataract and glaucoma surgery
    Budenz, Donald L.
    Gedde, Steven J.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2014, 25 (02) : 141 - 147
  • [3] Clear corneal incision architecture in the immediate postoperative period evaluated using optical coherence tomography
    Calladine, Daniel
    Packard, Richard
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (08) : 1429 - 1435
  • [4] Comparative Effectiveness of Antibiotic Prophylaxis in Cataract Surgery
    Herrinton, Lisa J.
    Shorstein, Neal H.
    Paschal, John F.
    Liu, Liyan
    Contreras, Richard
    Winthrop, Kevin L.
    Chang, William J.
    Melles, Ronald B.
    Fong, Donald S.
    [J]. OPHTHALMOLOGY, 2016, 123 (02) : 287 - 294
  • [5] ReSure Sealant for Pars Plana Vitrectomy Wound Closure
    Ho, Vincent Y.
    Shah, Gaurav K.
    Liu, Enchun M.
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2015, 46 (10) : 1042 - 1044
  • [6] Hydrogel sealant versus sutures to prevent fluid egress after cataract surgery
    Masket, Samuel
    Hovanesian, John A.
    Levenson, Jeffrey
    Tyson, Farrell
    Flynn, William
    Endl, Michael
    Majmudar, Parag A.
    Modi, Satish
    Chu, Ralph
    Raizman, Michael B.
    Lane, Stephen S.
    Kim, Terry
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (12) : 2057 - 2066
  • [7] Use of a calibrated force gauge in clear corneal cataract surgery to quantify point-pressure manipulation
    Masket, Samuel
    Hovanesian, John
    Raizman, Michael
    Wee, Daniel
    Fram, Nicole
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (04) : 511 - 518
  • [8] Bacterial-sized particle inflow through sutured clear corneal incisions in a laboratory human model
    May, William N.
    Castro-Combs, Juan
    Kashiwabuchi, Renata T.
    Hertzog, Hans
    Tattiyakul, Woranart
    Kahn, Yasin A.
    Hirai, Flavio
    Gower, Emily W.
    Behrens, Ashley
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06) : 1140 - 1146
  • [9] Hydrogel ocular sealant for clear corneal incisions in cataract surgery
    Nallasamy, Nambi
    Grove, Karen E.
    Legault, Gary L.
    Daluvoy, Melissa B.
    Kim, Terry
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (08) : 1010 - 1014
  • [10] A prospective comparison between trabeculectomy with mitomycin C and phacotrabeculectomy with mitomycin C
    Ogata-Iwao, Minako
    Inatani, Masaru
    Takihara, Yuji
    Inoue, Toshihiro
    Iwao, Keiichiro
    Tanihara, Hidenobu
    [J]. ACTA OPHTHALMOLOGICA, 2013, 91 (06) : e500 - e501