Fire behavior of axially loaded slender high strength concrete-filled tubular columns

被引:130
作者
Romero, Manuel L. [1 ]
Moliner, V. [2 ]
Espinos, A. [1 ]
Ibanez, C. [1 ]
Hospitaler, A. [1 ]
机构
[1] Univ Politecn Valencia, Inst Ciencia & Tecnol Hormigon ICITECH, Valencia, Spain
[2] AIDICO, Ctr Tecn Fuego, Valencia, Spain
关键词
Fire resistance; Composite column; Concrete-filled tubular column; High strength concrete; STEEL TUBE COLUMNS; RESISTANCE; DESIGN;
D O I
10.1016/j.jcsr.2011.06.012
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes sixteen fire tests conducted on slender circular hollow section columns filled with normal and high strength concrete, subjected to concentric axial loads. The test parameters were the nominal strength of concrete (30 and 80 MPa), the infilling type (plain concrete, reinforced concrete and steel fiber reinforced concrete) and the axial load level (20% and 40%). The columns were tested under fixed-pinned boundary conditions and the relative slenderness at room temperature was higher than 0.5 in all of the cases. A numerical model was validated against the tests, in order to extend the results and understand the failure mode of such columns. It is the aim of this paper to study the influence in a fire situation of the use of high strength concrete, as opposed to normal strength concrete. The results have shown that for slender columns subjected to high temperatures, the behavior of high strength concrete was different than for stub columns. spalling not being observed in the experiments. Furthermore, the addition of steel fibers was not found very advantageous in slender columns, since no increment in terms of fire resistance was obtained for the columns which used this type of reinforcement. However, the addition of reinforcing bars seems to be the solution in some cases, where the use of external fire protection wants to be avoided in the design of HSS structures, since the reinforcing bars allow the tube to resist a higher axial load. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1953 / 1965
页数:13
相关论文
共 26 条
[1]   Numerical and experimental investigation of the behavior of high strength concrete columns in fire [J].
Ali, Faris ;
Nadjai, Ali ;
Choi, S. .
ENGINEERING STRUCTURES, 2010, 32 (05) :1236-1243
[2]   Simplified fire design for composite hollow-section columns [J].
Aribert, J. M. ;
Renaud, Ch ;
Zhao, B. .
PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2008, 161 (06) :325-336
[3]  
CEN, 2005, EN 1994-1-2
[4]  
CHABOT M, 1992, 628 I RES CONSTR NAT
[5]   Fire Resistance of Concrete Filled Square Steel Tube Columns Subjected to Eccentric Axial Load [J].
Chung, Kyungsoo ;
Park, Suhee ;
Choi, Sungmo .
INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2009, 9 (01) :69-76
[6]   Realistic modelling of thermal and structural behaviour of unprotected concrete filled tubular columns in fire [J].
Ding, J. ;
Wang, Y. C. .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2008, 64 (10) :1086-1102
[7]   Fire behaviour of concrete filled elliptical steel columns [J].
Espinos, Ana ;
Gardner, Leroy ;
Romero, Manuel L. ;
Hospitaler, Antonio .
THIN-WALLED STRUCTURES, 2011, 49 (02) :239-255
[8]   Advanced model for predicting the fire response of concrete filled tubular columns [J].
Espinos, Ana ;
Romero, Manuel L. ;
Hospitaler, Antonio .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (8-9) :1030-1046
[9]   An experimental study and calculation on the fire resistance of concrete-filled SHS and RHS columns [J].
Han, LH ;
Yang, YF ;
Xu, L .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2003, 59 (04) :427-452
[10]   Experimental study and calculation of fire resistance of concrete-filled hollow steel columns [J].
Han, LH ;
Zhao, XL ;
Yang, YF ;
Feng, JB .
JOURNAL OF STRUCTURAL ENGINEERING, 2003, 129 (03) :346-356