Out-of-field doses in pediatric craniospinal irradiations with 3D-CRT, VMAT, and scanning proton radiotherapy: A phantom study

被引:17
作者
Majer, Marija [1 ]
Ambrozova, Iva [2 ]
Davidkova, Marie [2 ]
De Saint-Hubert, Marijke [3 ]
Kasabasic, Mladen [4 ,5 ]
Knezevic, Zeljka [1 ]
Kopec, Renata [6 ]
Krzempek, Dawid [6 ]
Krzempek, Katarzyna [6 ]
Miljanic, Saveta [1 ]
Mojzeszek, Natalia [6 ]
Versic, Ivan [7 ]
Stolarczyk, Liliana [6 ,8 ]
Harrison, Roger M. [9 ]
Olko, Pawel [6 ]
机构
[1] Rudjer Boskovic Inst, Bijenicka C 54, Zagreb 10000, Croatia
[2] CAS, Inst Nucl Phys, Rez, Czech Republic
[3] Belgium Nucl Res Ctr, Mol, Belgium
[4] Osijek Univ Hosp, Osijek, Croatia
[5] JJ Strossmayer Univ Osijek, Fac Med Osijek, Osijek, Croatia
[6] Polish Acad Sci, Inst Nucl Phys, Krakow, Poland
[7] Univ Zagreb, Fac Sci, Dept Phys, Zagreb, Croatia
[8] Danish Ctr Particle Therapy, Aarhus, Denmark
[9] Univ Newcastle, Newcastle Upon Tyne, Tyne & Wear, England
关键词
3D-CRT; anthropomorphic phantom; craniospinal irradiation; out-of-field dose; scanning proton therapy; VMAT; INTENSITY-MODULATED RADIOTHERAPY; LINEAR-ENERGY-TRANSFER; STRAY RADIATION; 2ND CANCER; HELICAL TOMOTHERAPY; EXTERNAL-BEAM; X-RAY; PHOTON; NEUTRON; RISK;
D O I
10.1002/mp.15493
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Craniospinal irradiation (CSI) has greatly increased survival rates for patients with a diagnosis of medulloblastoma and other primitive neuroectodermal tumors. However, as it includes exposure of a large volume of healthy tissue to unwanted doses, there is a strong concern about the complications of the treatment, especially for the children. To estimate the risk of second cancers and other unwanted effects, out-of-field dose assessment is necessary. The purpose of this study is to evaluate and compare out-of-field doses in pediatric CSI treatment using conventional and advanced photon radiotherapy (RT) and advanced proton therapy. To our knowledge, it is the first such comparison based on in-phantom measurements. Additionally, for out-of-field doses during photon RT in this and other studies, comparisons were made using analytical modeling. Methods In order to describe the out-of-field doses absorbed in a pediatric patient during actual clinical treatment, an anthropomorphic phantom, which mimics the 10-year-old child, was used. Photon 3D-conformal RT (3D-CRT) and two advanced, highly conformal techniques: photon volumetric-modulated arc therapy (VMAT) and active pencil beam scanning (PBS) proton RT were used for CSI treatment. Radiophotoluminescent and poly-allyl-diglycol-carbonate nuclear track detectors were used for photon and neutron dosimetry in the phantom, respectively. Out-of-field doses from neutrons were expressed in terms of dose equivalent. A two-Gaussian model was implemented for out-of-field doses during photon RT. Results The mean VMAT photon doses per target dose to all organs in this study were under 50% of the target dose (i.e., <500 mGy/Gy), while the mean 3D-CRT photon dose to oesophagus, gall bladder, and thyroid, exceeded that value. However, for 3D-CRT, better sparing was achieved for eyes and lungs. The mean PBS photon doses for all organs were up to three orders of magnitude lower compared to VMAT and 3D-CRT and exceeded 10 mGy/Gy only for the oesophagus, intestine, and lungs. The mean neutron dose equivalent during PBS for eight organs of interest (thyroid, breasts, lungs, liver, stomach, gall bladder, bladder, prostate) ranged from 1.2 mSv/Gy for bladder to 23.1 mSv/Gy for breasts. Comparison of out-of-field doses in this and other phantom studies found in the literature showed that a simple and fast two-Gaussian model for out-of-field doses as a function of distance from the field edge can be applied in a CSI using photon RT techniques. Conclusions PBS is the most promising technique for out-of-field dose reduction in comparison to photon techniques. Among photon techniques, VMAT is a preferred choice for most of out-of-field organs and especially for the thyroid, while doses for eyes, breasts, and lungs are lower for 3D-CRT. For organs outside the field edge, a simple analytical model can be helpful for clinicians involved in treatment planning using photon RT but also for retrospective data analysis for cancer risk estimates and epidemiology in general.
引用
收藏
页码:2672 / 2683
页数:12
相关论文
共 61 条
  • [41] The risk of developing a second cancer after receiving craniospinal proton irradiation
    Newhauser, Wayne D.
    Fontenot, Jonas D.
    Mahajan, Anita
    Kornguth, David
    Stovall, Marilyn
    Zheng, Yuanshui
    Taddei, Phillip J.
    Mirkovic, Dragan
    Mohan, Radhe
    Cox, James D.
    Woo, Shiao
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (08) : 2277 - 2291
  • [42] Intensity-modulated radiotherapy for craniospinal irradiation: Target volume considerations, dose constraints, and competing risks
    Parker, William
    Filion, Edith
    Roberge, David
    Freeman, Carolyn R.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01): : 251 - 257
  • [43] Pediatric craniospinal irradiation with a short partial-arc VMAT technique for medulloblastoma tumors in dosimetric comparison
    Pollul, Gerhard
    Bostel, Tilman
    Grossmann, Sascha
    Akbaba, Sati
    Karle, Heiko
    Stockinger, Marcus
    Schmidberger, Heinz
    [J]. RADIATION ONCOLOGY, 2020, 15 (01)
  • [44] Dosimetric evaluation of a glass dosimeter for proton beam measurements
    Rah, Jeong-Eun
    Oh, Do Hoon
    Shin, Dongho
    Kim, Dae-Hyun
    Ji, Young Hoon
    Kim, Jong Won
    Park, Sung Yong
    [J]. APPLIED RADIATION AND ISOTOPES, 2012, 70 (08) : 1616 - 1623
  • [45] Evaluations of secondary cancer risk in spine radiotherapy using 3DCRT, IMRT, and VMAT: A phantom study
    Rehman, Jalil Ur
    Tailor, Ramesh C.
    Isa, Muhammad
    Afzal, Muhammad
    Chow, James
    Ibbott, Geoffrey S.
    [J]. MEDICAL DOSIMETRY, 2015, 40 (01) : 70 - 75
  • [46] Experimental evaluation of neutron dose in radiotherapy patients: Which dose?
    Romero-Exposito, M.
    Domingo, C.
    Sanchez-Doblado, F.
    Ortega-Gelabert, O.
    Gallego, S.
    [J]. MEDICAL PHYSICS, 2016, 43 (01) : 360 - 367
  • [47] Study of out-of-field dose in photon radiotherapy: A commercial treatment planning system versus measurements and Monte Carlo simulations
    Sanchez-Nieto, B.
    Medina-Ascanio, K. N.
    Rodriguez-Mongua, J. L.
    Doerner, E.
    Espinoza, I
    [J]. MEDICAL PHYSICS, 2020, 47 (09) : 4616 - 4625
  • [48] Neutrons in active proton therapy: Parameterization of dose and dose equivalent
    Schneider, Uwe
    Halg, Roger A.
    Lomax, Tony
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (02): : 113 - 123
  • [49] Dosimetric comparison of five different techniques for craniospinal irradiation across 15 European centers: analysis on behalf of the SIOP-E-BTG (radiotherapy working group)
    Seravalli, Enrica
    Bosman, Mirjam
    Lassen-Ramshad, Yasmin
    Vestergaard, Anne
    Oldenburger, Foppe
    Visser, Jorrit
    Koutsouveli, Efi
    Paraskevopoulou, Chryssa
    Horan, Gail
    Ajithkumar, Thankamma
    Timmermann, Beate
    Fuentes, Carolina-Sofia
    Whitfield, Gillian
    Marchant, Thomas
    Padovani, Laetitia
    Gamier, Eloise
    Gandola, Lorenza
    Meroni, Silvia
    Hoeben, Bianca A. W.
    Kusters, Martijn
    Alapetite, Claire
    Losa, Sandra
    Goudjil, Farid
    Magelssen, Henriette
    Evensen, Morten Egeberg
    Saran, Frank
    Smyth, Gregory
    Rombi, Barbara
    Righetto, Roberto
    Kortmann, Rolf-Dieter
    Janssens, Geert O.
    [J]. ACTA ONCOLOGICA, 2018, 57 (09) : 1240 - 1249
  • [50] Advantage of protons compared to conventional X-ray or IMRT in the treatment of a pediatric patient with medulloblastoma
    St Clair, WH
    Adams, JA
    Bues, M
    Fullerton, BC
    La Shell, S
    Kooy, HM
    Loeffler, JS
    Tarbell, NJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 58 (03): : 727 - 734