Discriminators of pseudoprogression and true progression in high-grade gliomas: A systematic review and meta-analysis

被引:21
作者
Taylor, Chris [1 ]
Ekert, Justyna O. [2 ]
Sefcikova, Viktoria [1 ]
Fersht, Naomi [3 ]
Samandouras, George [2 ,4 ]
机构
[1] UCL, UCL Queen Sq Inst Neurol, Gower St,Queen Sq, London WC1E 6BT, England
[2] UCL, Wellcome Ctr Human Neuroimaging, 12 Queen Sq, London, England
[3] Univ Coll London Hosp NHS Fdn Trust, Dept Oncol, London, England
[4] Natl Hosp Neurol & Neurosurg, Victor Horsley Dept Neurosurg, Queen Sq, London, England
关键词
CEREBRAL BLOOD-VOLUME; CONCURRENT RADIATION-THERAPY; CONCOMITANT TEMOZOLOMIDE; TUMOR PROGRESSION; SIGNAL INTENSITY; MR SPECTROSCOPY; PERFUSION MRI; GLIOBLASTOMA; DIFFERENTIATION; DIFFUSION;
D O I
10.1038/s41598-022-16726-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
High-grade gliomas remain the most common primary brain tumour with limited treatments options and early recurrence rates following adjuvant treatments. However, differentiating true tumour progression (TTP) from treatment-related effects or pseudoprogression (PsP), may critically influence subsequent management options. Structural MRI is routinely employed to evaluate treatment responses, but misdiagnosis of TTP or PsP may lead to continuation of ineffective or premature cessation of effective treatments, respectively. A systematic review and meta-analysis were conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-analyses method. Embase, MEDLINE, Web of Science and Google Scholar were searched for methods applied to differentiate PsP and TTP, and studies were selected using pre-specified eligibility criteria. The sensitivity and specificity of included studies were summarised. Three of the identified methods were compared in a separate subgroup meta-analysis. Thirty studies assessing seven distinct neuroimaging methods in 1372 patients were included in the systematic review. The highest performing methods in the subgroup analysis were DWI (AUC = 0.93 [0.91-0.95]) and DSC-MRI (AUC = 0.93 [0.90-0.95]), compared to DCE-MRI (AUC = 0.90 [0.87-0.93]). 18F-fluoroethyltyrosine PET (18F-FET PET) and amide proton transfer-weighted MRI (APTw-MRI) also showed high diagnostic accuracy, but results were based on few low-powered studies. Both DWI and DSC-MRI performed with high sensitivity and specificity for differentiating PsP from TTP. Considering the technical parameters and feasibility of each identified method, the authors suggested that, at present, DSC-MRI technique holds the most clinical potential.
引用
收藏
页数:12
相关论文
共 80 条
[1]   Incidence of Tumour Progression and Pseudoprogression in High-Grade Gliomas: a Systematic Review and Meta-Analysis [J].
Abbasi, Abdul W. ;
Westerlaan, Henriette E. ;
Holtman, Gea A. ;
Aden, Kamal M. ;
van Laar, Peter Jan ;
van der Hoorn, Anouk .
CLINICAL NEURORADIOLOGY, 2018, 28 (03) :401-411
[2]  
[Anonymous], 2018, US Food and Drug Administration
[3]  
[Anonymous], 2020, REV MAN REVMAN COMP
[4]  
Asao C, 2005, AM J NEURORADIOL, V26, P1455
[5]   Percent Change of Perfusion Skewness and Kurtosis: A Potential Imaging Biomarker for Early Treatment Response in Patients with Newly Diagnosed Glioblastomas [J].
Baek, Hye Jin ;
Kim, Ho Sung ;
Kim, Namkug ;
Choi, Young Jun ;
Kim, Young Joong .
RADIOLOGY, 2012, 264 (03) :834-843
[6]   Basic principles of diffusion-weighted imaging [J].
Bammer, R .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 (03) :169-184
[7]  
Birk Harjus S, 2017, CNS Oncol, V6, P61, DOI 10.2217/cns-2016-0013
[8]  
Boxerman JL, 2006, AM J NEURORADIOL, V27, P859
[9]   Optimal database combinations for literature searches in systematic reviews: a prospective exploratory study [J].
Bramer, Wichor M. ;
Rethlefsen, Melissa L. ;
Kleijnen, Jos ;
Franco, Oscar H. .
SYSTEMATIC REVIEWS, 2017, 6
[10]   Clinical features, mechanisms, and management of pseudoprogression in malignant gliomas [J].
Brandsma, Dieto ;
Stalpers, Lukas ;
Taal, Walter ;
Sminia, Peter ;
van den Bent, Martinj .
LANCET ONCOLOGY, 2008, 9 (05) :453-461