Combined leadless pacemaker and subcutaneous implantable defibrillator therapy: feasibility, safety, and performance

被引:66
作者
Tjong, F. V. Y. [1 ]
Brouwer, T. F. [1 ]
Smeding, L. [1 ]
Kooiman, K. M. [1 ]
de Groot, J. R. [1 ]
Ligon, D. [2 ]
Sanghera, R. [3 ]
Schalij, M. J. [4 ]
Wilde, A. A. M. [1 ]
Knops, R. E. [1 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Clin & Expt Cardiol, AMC Heart Ctr, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
[2] St Jude Med, Sunnyvale, CA USA
[3] Boston Sci Corp, St Paul, MN USA
[4] Leiden Univ, Med Ctr, Dept Cardiol, Leiden, Netherlands
来源
EUROPACE | 2016年 / 18卷 / 11期
关键词
Pacemaker; Leadless pacing; Subcutaneous ICD; Animal experiments; Human; CARDIAC-PACEMAKER; EFFICACY; EXPERIENCE;
D O I
10.1093/europace/euv457
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The subcutaneous implantable cardioverter-defibrillator (S-ICD) and leadless pacemaker (LP) are evolving technologies that do not require intracardiac leads. However, interactions between these two devices are unexplored. We investigated the feasibility, safety, and performance of combined LP and S-ICD therapy, considering (i) simultaneous device-programmer communication, (ii) S-ICD rhythm discrimination during LP communication and pacing, and (iii) post-shock LP performance. The study consists of two parts. Animal experiments: Two sheep were implanted with both an S-ICD and LP (Nanostim, SJM), and the objectives above were tested. Human experience: Follow-up of one S-ICD patient with bilateral subclavian occlusion who received an LP and two LP (all Nanostim, SJM) patients (without S-ICD) who received electrical cardioversion (ECV) are presented. Animal experiments : Simultaneous device-programmer communication was successful, but LP-programmer communication telemetry was temporarily lost (2 +/- 2 s) during ventricular fibrillation (VF) induction and 4/54 shocks. Leadless pacemaker communication and pacing did not interfere with S-ICD rhythm discrimination. Additionally, all VF episodes (n = 12/12), including during simultaneous LP pacing, were detected and treated by the S-ICD. Post-shock LP performance was unaltered, and no post-shock device resets or dislodgements were observed (24 S-ICD and 30 external shocks). Human experience : The S-ICD/LP patient showed adequate S-ICD sensing during intrinsic rhythm, nominal, and high-output LP pacing. Two LP patients (without S-ICD) received ECV during follow-up. No impact on performance or LP dislodgements were observed. Combined LP and S-ICD therapy appears feasible in all animal experiments (n = 2) and in one human subject. No interference in sensing and pacing during intrinsic and paced rhythm was noted in both animal and human subjects. However, induced arrhythmia testing was not performed in the patient. Defibrillation therapy did not seem to affect LP function. More data on safety and performance are needed.
引用
收藏
页码:1740 / 1747
页数:8
相关论文
共 21 条
[1]   Impeding Sudden Cardiac Death Despite Subcutaneous Implantable Defibrillator Due to Fatal Crosstalk [J].
Akin, Ibrahim ;
Roeger, Susanne ;
Borggrefe, Martin ;
Kuschyk, Juergen .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (05) :613-614
[2]   An Entirely Subcutaneous Implantable Cardioverter-Defibrillator [J].
Bardy, Gust H. ;
Smith, Warren M. ;
Hood, Margaret A. ;
Crozier, Ian G. ;
Melton, Iain C. ;
Jordaens, Luc ;
Theuns, Dominic ;
Park, Robert E. ;
Wright, David J. ;
Connelly, Derek T. ;
Fynn, Simon P. ;
Murgatroyd, Francis D. ;
Sperzel, Johannes ;
Neuzner, Joerg ;
Spitzer, Stefan G. ;
Ardashev, Andrey V. ;
Oduro, Amo ;
Boersma, Lucas ;
Maass, Alexander H. ;
Van Gelder, Isabelle C. ;
Wilde, Arthur A. ;
van Dessel, Pascal F. ;
Knops, Reinoud E. ;
Barr, Craig S. ;
Lupo, Pierpaolo ;
Cappato, Riccardo ;
Grace, Andrew A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (01) :36-44
[3]   Safety and Efficacy of the Totally Subcutaneous Implantable Defibrillator 2-Year Results From a Pooled Analysis of the IDE Study and EFFORTLESS Registry [J].
Burke, Martin C. ;
Gold, Michael R. ;
Knight, Bradley P. ;
Barr, Craig S. ;
Theuns, Dominic A. M. J. ;
Boersma, Lucas V. A. ;
Knops, Reinoud E. ;
Weiss, Raul ;
Leon, Angel R. ;
Herre, John M. ;
Husby, Michael ;
Stein, Kenneth M. ;
Lambiase, Pier D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (16) :1605-1615
[4]   Histological findings around electrodes in pacemaker and implantable cardioverter-defibrillator patients: comparison of steroid-eluting and non-steroid-eluting electrodes [J].
Dvorak, Petr ;
Novak, Miroslav ;
Kamaryt, Pavel ;
Slana, Bronislava ;
Lipoldova, Jolana ;
Dvorak, Pavel .
EUROPACE, 2012, 14 (01) :117-123
[5]   Are Leadless Pacemakers a Niche or the Future of Device Therapy? [J].
Gold, Michael R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (15) :1505-1508
[6]   Long-term thrombosis after transvenous permanent pacemaker implantation [J].
Goto, Y ;
Abe, T ;
Sekine, S ;
Sakurada, T .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (06) :1192-1195
[7]   Chronic Performance of a Leadless Cardiac Pacemaker 1-Year Follow-Up of the LEADLESS Trial [J].
Knops, Reinoud E. ;
Tjong, Fleur V. Y. ;
Neuzil, Petr ;
Sperzel, Johannes ;
Miller, Marc A. ;
Petru, Jan ;
Simon, Jaroslav ;
Sediva, Lucie ;
de Groot, Joris R. ;
Dukkipati, Srinivas R. ;
Koruth, Jacob S. ;
Wilde, Arthur A. M. ;
Kautzner, Josef ;
Reddy, Vivek Y. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (15) :1497-1504
[8]   Feasibility and Efficacy of Percutaneously Delivered Leadless Cardiac Pacing in an In Vivo Ovine Model [J].
Koruth, Jacob S. ;
Rippy, Marian K. ;
Khairkhahan, Alexander ;
Ligon, David A. ;
Hubbard, Christopher A. ;
St Goar, Frederick ;
Lee, Randall ;
Ribeiro, Leonardo ;
Miller, Marc ;
Dukkipati, Srinivas ;
Neuzil, Petr ;
Reddy, Vivek Y. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (03) :322-328
[9]   Occlusion of the subclavian vein after pacemaker implantation [J].
Kurisu, Satoshi ;
Inoue, Ichiro ;
Kawagoe, Takuji .
INTERNAL MEDICINE, 2008, 47 (13) :1279-1279
[10]   Subcutaneous implantable cardioverter-defibrillator: First single-center experience with other cardiac implantable electronic devices [J].
Kuschyk, Juergen ;
Stach, Ksenija ;
Tueluemen, Erol ;
Rudic, Boris ;
Liebe, Volker ;
Schimpf, Rainer ;
Borggrefe, Martin ;
Roeger, Susanne .
HEART RHYTHM, 2015, 12 (11) :2230-2238