共 54 条
Development and Calibration of an Organic-Diffusive Gradients in Thin Films Aquatic Passive Sampler for a Diverse Suite of Polar Organic Contaminants
被引:147
作者:
Challis, Jonathan K.
[1
]
Hanson, Mark L.
[2
]
Wong, Charles S.
[1
,3
,4
]
机构:
[1] Univ Manitoba, Dept Chem, Winnipeg, MB R3T 2N2, Canada
[2] Univ Manitoba, Dept Geog & Environm, Winnipeg, MB R3T 2N2, Canada
[3] Univ Winnipeg, Richardson Coll Environm, Dept Chem, Winnipeg, MB R3B 2E9, Canada
[4] Univ Winnipeg, Richardson Coll Environm, Dept Environm Studies & Sci, Winnipeg, MB R3B 2E9, Canada
基金:
加拿大自然科学与工程研究理事会;
关键词:
CHEMICAL INTEGRATIVE SAMPLER;
PERSONAL-CARE PRODUCTS;
SOLID-PHASE EXTRACTION;
WASTE-WATER EFFLUENT;
IN-SITU;
BIOACCUMULATIVE ORGANICS;
TRANSFORMATION PRODUCTS;
ENVIRONMENTS PART;
METAL-COMPLEXES;
BOUNDARY-LAYER;
D O I:
10.1021/acs.analchem.6b02749
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
A unique configuration of the diffusive gradients in thin films sampler for polar organics (o-DGT) without a poly(ether sulfone) membrane was developed, calibrated, and field-evaluated. Diffusion coefficients (D) through agarose diffusive gels ranged from (1.02 to 4.74) x 10(-6) cm(2)/s for 34 pharmaceuticals and pesticides at 5, 13, and 23 degrees C. Analyte-specific diffusiontemperature plots produced linear (r(2) > 0.85) empirical relationships whereby D could be estimated at any environmentally relevant temperature (i.e., matched to in situ water conditions). Linear uptake for all analytes was observed in a static renewal calibration experiment over 25 days except for three macrolide antibiotics, which reached saturation at 300 ng (15 d). Experimental sampling rates ranged from 8.8 to 16.1 mL/d and were successfully estimated with measured and modeled D within 19% and 30% average relative error, respectively. Under slow flowing (2.4 cm/s) and static conditions, the in situ diffusive boundary layer (DBL) thickness ranged from 0.023 to 0.075 cm, resulting in a maximum contribution to mass transfer of <45%. Estimated water concentrations by o-DGT at a wastewater treatment plant agreed well with grab samples and appeared to be less influenced by the boundary layer compared to that of polar organic chemical integrative samplers (POCIS) deployed simultaneously. The o-DGT sampler is a promising monitoring tool that is largely insensitive to the DBL under typical flow conditions, facilitating the application of measured/modeled diffusion-based sampling rates. This significantly reduces the need for sampler calibration, making o-DGT more widely applicable, reliable, and cost-effective compared to current polar passive samplers.
引用
收藏
页码:10583 / 10591
页数:9
相关论文