Model for dynamic liquid hold-up in a packed distillation column

被引:4
|
作者
Taiwo, EA [1 ]
Fasesan, SO [1 ]
机构
[1] Obafemi Awolowo Univ, Chem Engn Dept, Ife, Nigeria
关键词
D O I
10.1021/ie0210199
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A correlation for the estimation of the dynamic liquid hold-up in a packed distillation column was developed. It is based on the hydrodynamics of fluid flow in a packed distillation column. The model showed a deviation of less than 3.5% when compared with experimental data. The dynamic liquid hold-up was found to decrease with increasing packed height, and a strong dependence of column performance on the dynamic liquid hold-up was observed. The liquid hold up was, in general, found to be high at high Reynolds number of the gas phase and low at high relative volatility of the system components.
引用
收藏
页码:197 / 202
页数:6
相关论文
共 50 条
  • [21] DISPERSED PHASE HOLD-UP AND CHARACTERISTIC VELOCITY IN A PULSED PACKED EXTRACTION COLUMN
    Asadollahzadeh, Mehdi
    Safdari, Jaber
    Haghighi-Asl, Ali
    Torab-Mostaedi, Meisam
    CHEMICAL INDUSTRY & CHEMICAL ENGINEERING QUARTERLY, 2012, 18 (02) : 255 - 262
  • [22] A DYNAMIC MODEL FOR A PACKED BATCH DISTILLATION COLUMN
    KROPHOLLER, HW
    SPIKINS, DJ
    WHALLEY, F
    MEASUREMENT AND CONTROL, 1968, 1 (03): : T55 - +
  • [23] OPERATIVE DEFINITION AND THEORETICAL EVALUATION OF DYNAMIC HOLD-UP IN PACKED TOWERS
    COSTA, P
    CAGGERO, M
    CANEPA, B
    LODI, G
    QUADERNI DELL INGEGNERE CHIMICO ITALIANO, 1975, 11 (02): : 19 - 24
  • [24] A simple model for pressure drop and liquid hold-up in packed-bed bubble reactors
    Attou, A
    Ferschneider, G
    CHEMICAL ENGINEERING SCIENCE, 1999, 54 (21) : 5139 - 5144
  • [25] Measurements of Liquid Hold-Up on the Column Packing of Type K.
    Gierczycki, Andrzej
    Vychodil, Petr
    Stanek, Vladimir
    Grabbert, Gert
    Winkler, Kurt
    Inzynieria Chemiczna i Procesowa, 1986, 7 (02): : 341 - 346
  • [26] Influence of Liquid Flow on Gas Hold-up in Bubble Column.
    Kawalec-Peitrenko, Bozena
    Inzynieria Chemiczna i Procesowa, 1986, 7 (01): : 173 - 178
  • [27] Generalised model for heteroazeotropic batch distillation with variable decanter hold-up
    Hegely, L.
    Gerbaud, V.
    Lang, P.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 115 : 9 - 19
  • [28] A TENSOMETRIC METHOD TO DETERMINE THE HOLD-UP OF LIQUID IN PACKED-BED APPARATURES
    JIRICNY, V
    STANEK, V
    SMID, J
    JELINEK, V
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1982, 47 (08) : 2190 - 2200
  • [29] Back mixing and liquid hold-up in a cocurrent up-flow packed bed bioreactor
    Bayraktar, E
    Mehmetoglu, U
    CHEMICAL ENGINEERING COMMUNICATIONS, 2001, 185 : 125 - 140
  • [30] GAS HOLD-UP AND LONGITUDINAL DISPERSION OF LIQUID IN A ROTARY ANNULAR BUBBLE COLUMN
    OHSASA, K
    SAMBUICHI, M
    NAKAKURA, H
    KAGAKU KOGAKU RONBUNSHU, 1980, 6 (05) : 455 - 460