Enhanced sensitivity of 4-chlorophenol detection by use of nitrobenzene as a liquid membrane over a carbon nanotube-modified glassy carbon electrode

被引:5
作者
Phanthong, Chatuporn [1 ]
Somasundrum, Mithran [1 ]
机构
[1] King Mongkuts Univ Technol Thonburi, BEC PDTI, Bangkok 10150, Thailand
关键词
single-walled nanotubes; differential pulse voltammetry; phenol; preconcentration; liquid membrane;
D O I
10.1002/elan.200704111
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical utility of nitrobenzene as a liquid membrane for the detection of hydrophobic compounds was examined with a glassy carbon electrode, using 4-chlorophenol as the model analyte. Electrochemical experiments indicated a large partition coefficient for the entry of 4-chlorophenol into the nitrobenzene (7.6 x 10(2) +/- 1.5 x 10(2)). This was combined with an increase in effective electrode area by coating with single-walled nanotubes. Differential pulse voltammetry produced a linear response across the range 0.3 nM to 1.5 nM with a sensitivity of 1.1 x 10(-5) A nM(-1) cm(-2). To the best of our knowledge, this limit of detection for phenol is lower than other nonenzymatic modifications of carbon.
引用
收藏
页码:1024 / 1027
页数:4
相关论文
共 32 条
[1]   Spectroelectrochemical sensing based on multimode selectivity simultaneously achievable in a single device. 17. Improvement in detection limits using ultrathin perfluorosulfonated ionomer films in conjunction with continuous sample flow [J].
Andria, SE ;
Richardson, JN ;
Kaval, N ;
Zudans, I ;
Seliskar, CJ ;
Heineman, WR .
ANALYTICAL CHEMISTRY, 2004, 76 (11) :3139-3144
[2]   Electrochemistry of immobilised redox droplets: Concepts and applications [J].
Banks, CE ;
Davies, TJ ;
Evans, RG ;
Hignett, G ;
Wain, AJ ;
Lawrence, NS ;
Wadhawan, JD ;
Marken, F ;
Compton, RG .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2003, 5 (19) :4053-4069
[3]   DERIVATIZATION OF SURFACES AND SELF-INHIBITION IN IRREVERSIBLE ELECTROCHEMICAL REACTIONS - CYCLIC VOLTAMMETRY AND PREPARATIVE-SCALE ELECTROLYSIS [J].
BHUGUN, I ;
SAVEANT, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 395 (1-2) :127-131
[4]  
Cordero-Rando MDM, 1998, ANAL CHIM ACTA, V370, P231
[5]   Liquid chromatography/electrochemical detection of phenols at a poly[Ni-(Protoporphyrin IX)] chemically modified electrode [J].
DallOrto, VC ;
Danilowicz, C ;
Sobral, S ;
LoBalbo, A ;
Rezzano, I .
ANALYTICA CHIMICA ACTA, 1996, 336 (1-3) :195-199
[6]   Surfactant templated sulfonic acid functionalized silica microspheres as new efficient ion exchangers and electrode modifiers [J].
Ganesan, V ;
Walcarius, A .
LANGMUIR, 2004, 20 (09) :3632-3640
[7]   STRIPPING VOLTAMMETRY WITH PRECONCENTRATION THROUGH CHEMICAL-REACTIONS COUPLED TO CHARGE-TRANSFER IN AN IONOMER-COATED ELECTRODE - APPLICATION TO THE DETERMINATION OF A NITROSOAMINE [J].
GORSKI, W ;
COX, JA .
ANALYTICAL CHEMISTRY, 1992, 64 (22) :2706-2710
[8]   Hydrophobic interaction of analytes with permselective poly(N-vinyl amide) films on electrodes [J].
Hofbauer, M ;
Heineman, WR ;
Kreishman, GP ;
Steckhan, E .
ANALYTICAL CHEMISTRY, 1999, 71 (02) :399-406
[9]  
KRISTIANSEN N, 1994, ENVIRON SCI TECHNOL, V28, P166
[10]   GRAPHITIZED CARBON-BLACK IN POLYETHYLENE AS AN ELECTROCHEMICAL SENSOR [J].
LIBERTI, A ;
MORGIA, C ;
MASCINI, M .
ANALYTICA CHIMICA ACTA, 1985, 173 (JUL) :157-164