X-ray computed tomography of planetary materials: A primer and review of recent studies

被引:93
|
作者
Hanna, Romy D. [1 ]
Ketcham, Richard A. [1 ]
机构
[1] Univ Texas Austin, Jackson Sch Geosci, 2275 Speedway Stop C9000, Austin, TX 78712 USA
基金
美国国家科学基金会;
关键词
X-ray; Computed tomography; 3D imaging; Synchrotron; Radiation; Damage; Planetary; Meteorites; DIFFRACTION CONTRAST TOMOGRAPHY; BEAM HARDENING CORRECTION; QUANTITATIVE-ANALYSIS; ORDINARY CHONDRITES; CARBONACEOUS CHONDRITES; IMAGE-RECONSTRUCTION; METAL PHASES; IMPACT-MELT; MICRO-CT; METEORITE;
D O I
10.1016/j.chemer.2017.01.006
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
X-ray computed tomography (XCT) is a powerful 3D imaging technique that has been used to investigate meteorites, mission-returned samples, and other planetary materials of all scales from dust particles to large rocks. With this technique, a 3D volume representing the X-ray attenuation (which is sensitive to composition and density) of the materials within an object is produced, allowing various components and textures to be observed and quantified. As with any analytical technique, a thorough understanding of the underlying physical principles, system components, and data acquisition parameters provides a strong foundation for the optimal acquisition and interpretation of the data. Here we present a technical overview of the physics of XCT, describe the major components of a typical laboratory-based XCT instrument, and provide a guide for how to optimize data collection for planetary materials using such systems. We also discuss data processing, visualization and analysis, including a discussion of common data artifacts and how to minimize them. We review a variety of recent studies in which XCT has been used to study extraterrestrial materials and/or to address fundamental problems in planetary science. We conclude with a short discussion of anticipated future directions of XCT technology and application. (C) 2017 Elsevier GmbH. All rights reserved.
引用
收藏
页码:547 / 572
页数:26
相关论文
共 50 条
  • [21] X-ray luminescence computed tomography using a focused x-ray beam
    Zhang, Wei
    Lun, Michael C.
    Nguyen, Alex Anh-Tu
    Li, Changqing
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (11)
  • [22] X-ray Fluorescence Computed Tomography (XFCT) Imaging with a Superfine Pencil Beam X-ray Source
    Romero, Ignacio O.
    Fang, Yile
    Lun, Michael
    Li, Changqing
    PHOTONICS, 2021, 8 (07)
  • [23] X-ray computed tomography and its potential in ecological research: A review of studies and optimization of specimen preparation
    Gutierrez, Yeisson
    Ott, David
    Toepperwien, Mareike
    Salditt, Tim
    Scherber, Christoph
    ECOLOGY AND EVOLUTION, 2018, 8 (15): : 7717 - 7732
  • [24] X-Ray Computed Tomography Through Scatter
    Geva, Adam
    Schechner, Yoav Y.
    Chernyak, Yonatan
    Gupta, Rajiv
    COMPUTER VISION - ECCV 2018, PT XIV, 2018, 11218 : 37 - 54
  • [25] Accelerating X-ray Fluorescence Computed Tomography
    La Riviere, P. J.
    Vargas, P.
    Fu, G.
    Meng, L. J.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 1000 - +
  • [26] X-ray induced acoustic computed tomography
    Samant, P.
    Trevisi, L.
    Ji, X.
    Xiang, L.
    PHOTOACOUSTICS, 2020, 19 (19)
  • [27] Development of Carbon Nanotube X-ray System for Computed Tomography
    Ryu, Je Hwang
    Lee, Seung Ho
    Kim, Wan Sun
    Eom, Young Ju
    Kim, Jae Gon
    Lee, Soo Yeol
    Park, Kyu Chang
    Park, Hun Kuk
    2012 25TH INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE (IVNC), 2012, : 402 - +
  • [28] Benchtop x-ray fluorescence computed tomography (XFCT) imaging
    Romero, Ignacio O.
    Fang, Yile
    Lun, Michael
    Li, Changqing
    MEDICAL IMAGING 2021: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11600
  • [29] Advances in X-ray detectors for clinical and preclinical Computed Tomography
    Panetta, Daniele
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 809 : 2 - 12
  • [30] Industrial X-ray computed tomography applied to paleobotanical research
    Pika-Biolzi, M
    Hochuli, PA
    Flisch, A
    RIVISTA ITALIANA DI PALEONTOLOGIA E STRATIGRAFIA, 2000, 106 (03) : 369 - 377