The Impact of Cone-Beam Computed Tomography Exposure Parameters on Peri-Implant Artifacts: A Literature Review

被引:12
作者
Sawicki, Pawel [1 ]
Zawadzki, Pawel J. [1 ]
Regulski, Piotr [2 ,3 ]
机构
[1] Med Univ Warsaw, Dept Cranio Maxillofacial Surg Oral Surg & Implan, Warsaw, Poland
[2] Med Univ Warsaw, Dept Dent & Maxillofacial Radiol, Warsaw, Poland
[3] Cardinal Stefan Wyszynski Univ Warsaw, Ctr Digital Sci & Technol, Warsaw, Poland
关键词
radiation protection; dental implants; radiation; metal artifacts; cbct; REDUCTION ALGORITHM; VOLUME CORRECTION; ROOT FRACTURES; CBCT; CT; SCANS; FIELD; VIEW; SIZE;
D O I
10.7759/cureus.23035
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cone-beam computed tomography (CBCT) amounts to an excellent diagnostic tool to evaluate the peri-implant bone thickness in all dimensions. Despite the unquestionable advantages of CBCT, potential artifacts around dental implants might disturb the proper assessment of the surrounding structures. The artifacts may mask osseointegration, shallow bone defects, and other types of radiolucency, which make it difficult to establish an early diagnosis of bone loss. Proper diagnosis of bone defect is necessary to decide about surgical intervention. The aim of this literature review is to assess the CBCT exposure causing artifacts on the peri-implant structures. An electronic search of MEDLINE (PubMed) database includes studies published before July 2021 and supplemented by manual research. Clinical, ex vivo, in vitro, and animal studies evaluating the relationship between exposition parameters and occurrence of artifacts around the dental implant in CBCT studies were included. A literature review revealed that kilovoltage, tube current, and field of view may affect the occurrence of artifacts around dental implants, all of which would compromise radiological evaluation. Therefore, it is feasible to reduce the incidence of artifacts and improve the image quality by appropriate modification of the exposure parameters. However, the reduction of artifacts is often associated with a significant increase in radiation exposure; hence, an effort should be made to minimize the radiation dose in line with the ALARA (as low as reasonably achievable) principle.
引用
收藏
页数:11
相关论文
共 46 条
[1]   What do we know about ALARA? Is our knowledge sufficient about radiation safety? [J].
Atci, Ibrahim B. ;
Yilmaz, Hakan ;
Antar, Veysel ;
Ozdemir, Nuriye G. ;
Baran, Oguz ;
Sadillioglu, Sila ;
Ozel, Mehmet ;
Turk, Okan ;
Yaman, Mehmet ;
Topacoglu, Hakan .
JOURNAL OF NEUROSURGICAL SCIENCES, 2017, 61 (06) :597-602
[2]   Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691
[3]   Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth [J].
Bechara, B. ;
McMahan, C. Alex ;
Moore, W. S. ;
Noujeim, M. ;
Teixeira, F. B. ;
Geha, H. .
DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (05)
[4]   Evaluation of a cone beam CT artefact reduction algorithm [J].
Bechara, B. ;
McMahan, C. A. ;
Geha, H. ;
Noujeim, M. .
DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (05) :422-428
[5]   Metal artefact reduction with cone beam CT: an in vitro study [J].
Bechara, B. B. ;
Moore, W. S. ;
McMahan, C. A. ;
Noujeim, M. .
DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (03) :248-253
[6]   Number of basis images effect on detection of root fractures in endodontically treated teeth using a cone beam computed tomography machine: an in vitro study [J].
Bechara, Boulos ;
McMahan, C. Alex ;
Nasseh, Ibrahim ;
Geha, Hassem ;
Hayek, Elie ;
Khawam, Georges ;
Raad, Michel ;
Noujeim, Marcel .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 115 (05) :676-681
[7]   Contrast-to-noise ratio difference in small field of view cone beam computed tomography machines [J].
Bechara, Boulos ;
McMahan, Clyde A. ;
Moore, William S. ;
Noujeim, Marcel ;
Geha, Hassem ;
Teixeira, Fabricio B. .
JOURNAL OF ORAL SCIENCE, 2012, 54 (03) :227-232
[8]   Spatial resolution in CBCT machines for dental/maxillofacial applications-what do we know today? [J].
Bruellmann, D. ;
Schulze, R. K. W. .
DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (01)
[9]   Are metal artefact reduction algorithms effective to correct cone beam CT artefacts arising from the exomass? [J].
Candemil, Amanda Pelegrin ;
Salmon, Benjamin ;
Freitas, Deborah Queiroz ;
Bovi Ambrosano, Glaucia Maria ;
Haiter-Neto, Francisco ;
Oliveira, Matheus Lima .
DENTOMAXILLOFACIAL RADIOLOGY, 2019, 48 (03)
[10]   Quantitative analysis of metallic artifacts caused by dental metals: comparison of cone-beam and multi-detector row CT scanners [J].
Chindasombatjaroen, Jira ;
Kakimoto, Naoya ;
Murakami, Shumei ;
Maeda, Yoshinobu ;
Furukawa, Souhei .
ORAL RADIOLOGY, 2011, 27 (02) :114-120