Plasma density gradient measurement using laser deflection

被引:11
作者
Brockington, SJE [1 ]
Horton, RD
Hwang, DQ
Evans, RW
Howard, SJ
Thio, YCF
机构
[1] Univ Calif Davis, Dept Elect & Comp Engn, Davis, CA 95616 USA
[2] Univ Calif Davis, Dept Appl Sci, Livermore, CA USA
[3] US DOE, Off Fus Energy Sci, Washington, DC 20585 USA
关键词
D O I
10.1063/1.1935447
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
For a given chord through a plasma, changes in the line integrated index of refraction as a result of a transverse density gradient can be observed by measuring the angle of deflection of a laser beam. In contrast to laser interferometers, this method of density profile measurement places modest requirements on laser quality and alignment procedures, allowing measurements to be conducted with short coherence length commercial laser diodes and segmented photodiode detectors. A prototype implementation of this scheme has been constructed and tested on the compact toroid injection experiment (CTIX). At densities comparable to magnetic fusion plasmas, laser deflections in the nanoradian range were measured. By assuming a particular density profile, a sensitivity of similar to 10(12) cm(-3)/nrad was obtained. This produced estimates of CTIX peak density in reasonable agreement with conventional interferometry data. The final goal of this diagnostic is a simple, reliable, array deployable density profile diagnostic. (c) 2005 American Institute of Physics.
引用
收藏
页数:7
相关论文
共 12 条
[1]   The use of a Shack-Hartmann wave front sensor for electron density characterization of high density plasmas [J].
Baker, KL ;
Brase, J ;
Kartz, M ;
Olivier, SS ;
Sawvel, B ;
Tucker, J .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (11) :3784-3788
[2]   Compact toroid dynamics in the Compact Toroid Injection Experiment [J].
Baker, KL ;
Hwang, DQ ;
Evans, RW ;
Horton, RD ;
McLean, HS ;
Terry, SD ;
Howard, S ;
DiCaprio, CJ .
NUCLEAR FUSION, 2002, 42 (01) :94-99
[3]  
CUNEO ME, 1991, IEEE T PLASMA SCI, V19
[4]   FAST, SENSITIVE LASER DEFLECTION SYSTEM SUITABLE FOR TRANSIENT PLASMA ANALYSIS [J].
ENLOE, CL ;
GILGENBACH, RM ;
MEACHUM, JS .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1987, 58 (09) :1597-1600
[5]  
Ghahramani S., 1996, FUNDAMENTALS PROBABI
[6]  
Graeme J, 1999, AMPLIFIER APPL OP AM
[7]  
Graeme J. G., 1996, Photodiode Amplifiers. Op Amp Solutions
[8]   Telescopic refractive index gradient diagnostic of an ion diode anode plasma [J].
Knyazev, BA ;
Greenly, JB ;
Hammer, DA ;
Krastelev, EG ;
Cuneo, ME .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (05) :2310-2321
[9]   Design and operation of a passively switched repetitive compact toroid plasma accelerator [J].
McLean, HS ;
Hwang, DQ ;
Horton, RD ;
Evans, RW ;
Terry, SD ;
Thomas, JC ;
Raman, R .
FUSION TECHNOLOGY, 1998, 33 (03) :252-272
[10]  
MOTCHENBACHER CD, 1973, LOW NOISE ELECT DESI