Degree of conversion of nanofilled and microhybrid composite resins photo-activated by different generations of LEDs

被引:30
作者
Iaskieviscz Ribeiro, Benicia Carolina [1 ]
Capelozza Boaventura, Juliana Maria [2 ]
de Brito-Goncalves, Joel [1 ]
de Souza Rastelli, Alessandra Nara [2 ]
Bagnato, Vanderlei Salvador [3 ]
Cury Saad, Jose Roberto [2 ]
机构
[1] Univ Fed Mato Grosso do Sul, Dent Sch Prof Albino Coimbra Filho, Campo Grande, MS, Brazil
[2] UNESP Univ Estadual Paulista, Dept Restorat Dent, Araraquara Sch Dent, Araraquara, SP, Brazil
[3] Univ Sao Paulo, Biophoton Lab, Phys Inst Sao Carlos, Sao Carlos, SP, Brazil
关键词
Composite resins; Fourier transform infrared spectroscopy; Nanotechnology; Light; LIGHT-INTENSITY; DENTAL RESINS; POLYMERIZATION; TEMPERATURE; CONTRACTION; HALOGEN; STRESS; CURE;
D O I
10.1590/S1678-77572012000200015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: This study aimed at evaluating the degree of conversion (DC) of four composite resins, being one nanofilled and 3 microhybrid resins, photo-activated with second- and third-generation light-emitting diodes (LEDs). Material and methods: Filtek (TM) Z350 nanofilled composite resins and Amelogen (R) Plus, Vit-l-escence (TM) and Opallis microhybrid resins were photo-activated with two second-generation LEDs (Radii-cal and Elipar Free Light (TM) 2) and one third-generation LED (Ultra-Lume LED 5) by continuous light mode, and a quartz halogen-tungsten bulb (QHT, control). After 24 h of storage, the samples were pulverized into fine powder and 5 mg of each material were mixed with 100 mg of potassium bromide (KBr). After homogenization, they were pressed, which resulted in a pellet that was evaluated using an infrared spectromer (Nexus 470, Thermo Nicolet) equipped with TGS detector using diffuse reflectance (32 scans, resolution of 4 cm(-1)) coupled to a computer. The percentage of unreacted carbon-carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm-1) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm-1). Results: The ANOVA showed a significant effect on the interaction between the light-curing units (LCUs) and the composite resins (p<0.001). The Tukey's test showed that the nanofilled resin (Filtek (TM) Z350) and Opallis when photo-activated by the halogen lamp (QTH) had the lowest DC compared with the other microhybrid composite resins. The DC of the nanofilled resin (Filtek (TM) Z350) was also lower using LEDs. The highest degrees of conversion were obtained using the third-generation LED and one of second-generation LEDs (Elipar Free Light (TM) 2). Conclusions: The nanofilled resin showed the lowest DC, and the Vit-l-escence (TM) microhybrid composite resin showed the highest DC. Among the LCUs, it was not possible to establish an order, even though the second-generation LED Radii-cal provided the lowest DC.
引用
收藏
页码:212 / 217
页数:6
相关论文
共 30 条
[1]   Influence of composition on rate of polymerization contraction of light-curing resin composites [J].
Asmussen, E ;
Peutzfeldt, A .
ACTA ODONTOLOGICA SCANDINAVICA, 2002, 60 (03) :146-150
[2]   Spectroscopic and mechanical properties of dental resin composites cured with different light sources [J].
Conti, C ;
Giorgini, E ;
Landi, L ;
Putignano, A ;
Tosi, G .
JOURNAL OF MOLECULAR STRUCTURE, 2005, 744 :641-646
[3]   Degree of Conversion and Contraction Stress Development of a Resin Composite Irradiated Using Halogen and LED at Two C-factor Levels [J].
Cunha, L. G. ;
Alonso, R. C. B. ;
Neves, A. C. C. ;
de Goes, M. F. ;
Ferracane, J. L. ;
Sinhoreti, M. A. C. .
OPERATIVE DENTISTRY, 2009, 34 (01) :24-31
[4]   Relationship between the degree of conversion, solubility and salivary sorption of a hybrid and a nanofilled resin composite: Influence of the light-activation mode [J].
da Silva, Eduardo Moreira ;
Almeida, Giselle Soares ;
Poskus, Laiza Tatiana ;
Antunes Guimaraes, Jos Guilherme .
JOURNAL OF APPLIED ORAL SCIENCE, 2008, 16 (02) :161-166
[5]  
Felix CA, 2003, J ADHES DENT, V5, P283
[6]   Energy dependent polymerization of resin-based composite [J].
Halvorson, RH ;
Erickson, RL ;
Davidson, CL .
DENTAL MATERIALS, 2002, 18 (06) :463-469
[7]   Degree of conversion of composites measured by DTA and FTIR [J].
Imazato, S ;
McCabe, JF ;
Tarumi, H ;
Ehara, A ;
Ebisu, S .
DENTAL MATERIALS, 2001, 17 (02) :178-183
[8]   Degree of conversion and temperature rise during polymerization of composite resin samples with blue diodes [J].
Knezevic, A ;
Tarle, Z ;
Meniga, A ;
Sutalo, J ;
Pichler, G ;
Ristic, M .
JOURNAL OF ORAL REHABILITATION, 2001, 28 (06) :586-591
[9]   An application of nanotechnology in advanced dental materials [J].
Mitra, SB ;
Wu, D ;
Holmes, BN .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2003, 134 (10) :1382-1390
[10]   Effect of light guide tip diameter of LED-light curing unit on polymerization of light-cured composites [J].
Nitta, K .
DENTAL MATERIALS, 2005, 21 (03) :217-223