Microwave-Assisted Solid Sampling Analysis Coupled to Flame Furnace Atomic Absorption Spectrometry for Cd and Pb Determination in Food-Contact Polymers

被引:5
作者
Henn, Alessandra Schneider [1 ]
Frohlich, Angelica Chaiani [1 ]
Pedrotti, Matheus Felipe [1 ]
Cauduro, Vitoria Hagemann [1 ]
Oliveira, Marcos Leandro Silva [2 ]
Flores, Erico Marlon de Moraes [1 ]
Bizzi, Cezar Augusto [1 ]
机构
[1] Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
[2] Univ Costa, Dept Civil & Environm, Barranquilla 080002, Colombia
关键词
polymer analysis; MW-SS-FF-AAS; solid sampling; microwave-induced combustion; toxic element determination; INDUCED COMBUSTION; TRACE-ELEMENTS; CADMIUM DETERMINATION; BIOLOGICAL SAMPLES; DIGESTION; METALS; LEAD; MERCURY; COPPER; MN;
D O I
10.3390/su14010291
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Microwave-assisted solid sampling analysis coupled to flame furnace atomic absorption spectrometry (MW-SS-FF-AAS) was used for Cd and Pb determination in food-contact polymer samples, with the aim of minimizing reagents and laboratory waste. Operational parameters, such as the FF tube design, the oxygen flow rate, the flame stoichiometry, the sample mass, among others, were evaluated and optimized. Calibration was performed using only reference solutions, and the limits of quantification were 1.7 and 4.6 mu g g(-1) for Cd and Pb, respectively. Accuracy was assessed by the analysis of certified reference materials (CRMs), and by comparison with the results obtained by inductively coupled plasma mass spectrometry after microwave-assisted wet digestion. The MW-SS-FF-AAS results for the CRMs showed no statistical difference with the certified values, and good agreement was observed with the results of the digestion method. The MW-SS-FF-AAS method was considered suitable for Cd and Pb determination in food-contact polymers. The concentrations of Cd and Pb in the analyzed samples varied from <1.7 to 628 mu g g(-1), and from <4.6 to 614 mu g g(-1), respectively. As sample digestion is not necessary, the use of concentrated acids can be avoided by using the proposed MW-SS-FF-AAS method, greatly reducing waste generation.
引用
收藏
页数:12
相关论文
共 31 条
[1]   Electrothermal vaporization-inductively coupled plasma-mass spectrometry: A versatile tool for tackling challenging samples A critical review [J].
Aramendia, Maite ;
Resano, Martin ;
Vanhaecke, Frank .
ANALYTICA CHIMICA ACTA, 2009, 648 (01) :23-44
[2]   Focused microwave-induced combustion for digestion of botanical samples and metals determination by ICP OES and ICP-MS [J].
Barin, J. S. ;
Pereira, J. S. F. ;
Mello, P. A. ;
Knorr, C. L. ;
Moraes, D. P. ;
Mesko, M. F. ;
Nobrega, J. A. ;
Korn, M. G. A. ;
Flores, E. M. M. .
TALANTA, 2012, 94 :308-314
[3]   Microwave-induced Combustion Coupled to Flame Furnace Atomic Absorption Spectrometry for Determination of Cadmium and Lead in Botanical Samples [J].
Barin, Juliano S. ;
Bartz, Fabiane R. ;
Dressler, Valderi L. ;
Paniz, Jose N. G. ;
Flores, Erico M. M. .
ANALYTICAL CHEMISTRY, 2008, 80 (23) :9369-9374
[4]  
Barone C., 2015, FOOD PACKAGING HYGIE, P132
[5]  
Bart JCJ, 2005, ADDITIVES IN POLYMERS: INDUSTRIAL ANALYSIS AND APPLICATIONS, P1, DOI 10.1002/0470012064
[6]   Direct determination of metals in solid samples by graphite-furnace atomic absorption spectrometry: Does sample mass influence the analytical results? [J].
Belarra, MA ;
Crespo, C ;
Martinez-Garbayo, MP ;
Castillo, JR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (12) :1855-1860
[7]   Solid sampling coupled to flame furnace atomic absorption spectrometry for Mn and Ni determination in petroleum coke [J].
Bizzi, Cezar Augusto ;
Gottfried Paniz, Jose Neri ;
Rodrigues, Luiz Frederico ;
Dressler, Valderi Luiz ;
de Moraes Flores, Erico Marlon .
MICROCHEMICAL JOURNAL, 2010, 96 (01) :64-70
[8]   COMBUSTION AND VOLATILIZATION OF SOLID SAMPLES FOR DIRECT ATOMIC-ABSORPTION SPECTROMETRY USING SILICA OR NICKEL TUBE FURNACE ATOMIZERS [J].
CAMPOS, RC ;
CURTIUS, AJ ;
BERNDT, H .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (08) :669-673
[9]   Use of paper capsules for cadmium determination in biological samples by solid sampling flame atomic absorption spectrometry [J].
da Costa, AB ;
de Mattos, JCP ;
Müller, EI ;
Paniz, JNG ;
Dressler, VL ;
Flores, TMD .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (05) :583-588
[10]  
Flores E.M. M., 2014, Microwave-assisted sample preparation for trace element determination