Survey of computed tomography technique and radiation dose in Sudanese hospitals

被引:22
作者
Suliman, I. I. [1 ]
Abdalla, S. E. [1 ]
Ahmed, Nada A. [1 ]
Galal, M. A. [2 ]
Salih, Isam [1 ]
机构
[1] Sudan Atom Energy Commiss, Radiat Safety Inst, Khartoum, Sudan
[2] Univ Khartoum, Fac Sci, Dept Phys, Khartoum, Sudan
关键词
CT; Radiation dose; CT air kerma dose index; CT air kerma-length product; TUBE CURRENT MODULATION; DIAGNOSTIC REFERENCE LEVELS; CT; REDUCTION; OPTIMIZATION; COUNTRIES; PROJECTS; SCANNERS; CHEST;
D O I
10.1016/j.ejrad.2010.12.050
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to survey technique and radiation absorbed dose in CT examinations of adult in Sudan and to compare the results with the reference dose levels. Questionnaire forms were completed in nine hospitals and a sample of 445 CT examinations in patients. Information on patient, procedure, scanner, and technique for common CT examinations were collected. For each facility, the radiation absorbed dose was measured on CT dose phantom measuring 16 cm (head) and 32 cm (body) in diameter and was used to calculate the normalized CT air kerma index. Volume CT air kerma index (C-VOL), CT air kerma-length product (P-KL,P-CT) values were calculated using the measured normalized CT air kerma index and questionnaire information. The effective dose, E estimates was determined by using P-KL,P-CT measurements and appropriate normalized coefficients. Assuming the sample to offer a fair representative picture of CT practice patterns in Sudan, the mean C-VOL and P-KL,P-CT values were comparable or below the reference doses: 65 mGy and 758 mGy cm, respectively at head CT; 11.5 mGy and 327 mGy cm, respectively at chest CT; 11.6 mGy and 437 mGy cm, respectively at abdominal CT; and 11.0 mGy and 264 mGy cm, respectively at pelvis CT. Estimated effective doses were 1.6, 4.6, 6.6 and 4.0 mSv, respectively. The study offered a first national dose survey and provided a mean for quality control and optimization of CT practice within the country. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E544 / E551
页数:8
相关论文
共 35 条
  • [1] [Anonymous], 2000, Secretary-General's bulletin: Organization of the United Nations Office at Nairobi, P1
  • [2] [Anonymous], 1996, IAEA SAF SER
  • [3] [Anonymous], 2008, AAPM REP, DOI DOI 10.37206/97
  • [4] [Anonymous], 1991, Annals of the ICRP, V21
  • [5] Bongartz G., 1999, European Guidelines and Quality Criteria for Computed Tomography
  • [6] The trouble with CTDI100
    Boone, John M.
    [J]. MEDICAL PHYSICS, 2007, 34 (04) : 1364 - 1371
  • [7] It is time to retire the computed tomography dose index (CTDI) for CT quality assurance and dose optimization
    Brenner, DJ
    McCollough, CH
    Orton, CG
    [J]. MEDICAL PHYSICS, 2006, 33 (05) : 1189 - 1191
  • [8] Restructuring CT dosimetry - A realistic strategy for the future requiem for the pencil chamber
    Dixon, Robert L.
    [J]. MEDICAL PHYSICS, 2006, 33 (10) : 3973 - 3976
  • [9] Dose reduction in CT by anatomically adapted tube current modulation. 1. Simulation studies
    Gies, M
    Kalender, WA
    Wolf, H
    Suess, C
    Madsen, MT
    [J]. MEDICAL PHYSICS, 1999, 26 (11) : 2235 - 2247
  • [10] Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation
    Greess, H
    Lutze, J
    Nömayr, A
    Wolf, H
    Hothorn, T
    Kalender, WA
    Bautz, W
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (06) : 995 - 999