Inferior Radiographic and Functional Outcomes With Modular Stem in Metal-on-Metal Total Hip Arthroplasty

被引:1
|
作者
Laaksonen, Inari [1 ,2 ]
Galea, Vincent P. [1 ]
Connelly, James W. [1 ]
Matuszak, Sean J. [1 ]
Muratoglu, Orhun K. [1 ,2 ]
Malchau, Henrik [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Orthoped Surg, Harris Orthopaed Lab, Boston, MA 02114 USA
[2] Harvard Med Sch, Dept Orthopaed Surg, Boston, MA USA
关键词
total hip arthroplasty; hip stem; metal-on-metal; patient-reported outcome measure; osteolysis; blood metal ion level; FEMORAL STEM; FOLLOW-UP; ADVERSE-REACTIONS; CHROMIUM LEVELS; REPLACEMENT; REVISION; DIAMETER; REGISTRY; LESSONS; COBALT;
D O I
10.1016/j.arth.2017.08.042
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Data on the association between stem type and metal-on-metal (MoM) total hip arthroplasty (THA) performance are limited. The aim of this study is to investigate the effect of stem type on the prevalence of osteolysis and radiolucency, blood metal ion levels, and functional outcomes in patients with Articular Surface Replacement THA (ASR XL), a type of MoM THA. Methods: We analyzed 539 unilateral MoM THAs coupled with Summit (48%), Corail (35%), or S-ROM (17%) hip stems at a mean follow-up of 6.4 years. Fifty-four percent of the patients were male, and the mean age was 60 years. We studied radiographs, patient-reported outcome measures, and ion levels. Results: Patients with S-ROM hip stems were 3.8 times more likely to have osteolysis (P = .003) and 7.6 times more likely to have radiolucency (P<.001) than those treated with Summit hip stems. In addition, patients treated with S-ROM hip stems scored worse than those with Summit hip stems in 4 of the 5 patient-reported outcome measures: Harris Hip Score, Visual Analog Scale pain, University of California at Los Angeles activity, and EQ-5D index. All these differences were statistically significant and ranged from 5% to 10%, which is clinically significant. Conclusion: Patients with S-ROM hip stems had inferior functional and radiographic results compared to patients with Summit hip stems. Retrieval studies on large diameter head MoM THA and close follow-up of these patients with hip stems are needed to understand the mechanism causing the differences in outcomes between these stem types. (C) 2017 Published by Elsevier Inc.
引用
收藏
页码:464 / 469
页数:6
相关论文
共 50 条
  • [21] Metal-on-metal or metal-on-polyethylene for total hip arthroplasty: a meta-analysis of prospective randomized studies
    Qu, Xinhua
    Huang, Xiaolu
    Dai, Kerong
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (11) : 1573 - 1583
  • [22] Metal on Metal Total Hip Arthroplasty Using Modular Acetabular Shells
    Liudahl, Adam A.
    Liu, Steve S.
    Goetz, Devon D.
    Mahoney, Craig R.
    Callaghan, John J.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (05) : 867 - 871
  • [23] Large diameter metal-on-metal total hip arthroplasty for Crowe IV developmental dysplasia of the hip
    Parmaksizoglu, Atilla Sancar
    Ozkaya, Ufuk
    Bilgili, Fuat
    Basilgan, Seckin
    Kabukcuoglu, Yavuz
    HIP INTERNATIONAL, 2009, 19 (04) : 309 - 314
  • [24] Metal-on-Metal Hip Arthroplasty: A Comprehensive Review of the Current Literature
    Davis, Timothy P.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)
  • [25] Modular junction may be more problematic than bearing wear in metal-on-metal total hip arthroplasty
    Vendittoli, Pascal-Andre
    Masse, Vincent
    Kiss, Marc-Olivier
    Lusignan, Daniel
    Lavigne, Martin
    HIP INTERNATIONAL, 2019, 29 (03) : 262 - 269
  • [26] Is Metal-On-Metal Total Hip Arthroplasty Associated With Neurotoxicity?
    Bala, Abiram
    Penrose, Colin T.
    Seyler, Thorsten M.
    Randell, Timmothy R.
    Wellman, Samuel S.
    Bolognesi, Michael P.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (09) : S233 - +
  • [27] Pseudotumor in the Setting of Metal-on-Metal Total Hip Arthroplasty
    Sagoo, Navraj S.
    Sharma, Ruhi
    Johnson, Connor S.
    Stephenson, Kelly
    Aya, Kessiena L.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (05)
  • [28] Revision of Failed Metal-on-Metal Total Hip Arthroplasty: Midterm Outcomes of 203 Consecutive Cases
    Crawford, David A.
    Adams, Joanne B.
    Morris, Michael J.
    Berend, Keith R.
    Lombardi, Adolph V., Jr.
    JOURNAL OF ARTHROPLASTY, 2019, 34 (08) : 1755 - 1760
  • [29] Metal-on-metal articulation in total hip arthroplasty: update
    Srinivasan, Anand
    Levine, Brett R.
    Jacobs, Joshua J.
    CURRENT ORTHOPAEDIC PRACTICE, 2011, 22 (03): : 231 - 235
  • [30] Femoral offset found not to affect metal ion levels in metal-on-metal total hip arthroplasty
    Pomeroy, Eoghan
    Macnamara, Fergal
    Murphy, Evelyn
    McGoldrick, Niall
    Mahapatra, Anant
    Awan, Nasir
    IRISH JOURNAL OF MEDICAL SCIENCE, 2019, 188 (01) : 149 - 153