Cross-validation for the selection of spectral variables using the successive projections algorithm

被引:53
作者
Galvao, Roberto Kawakami Harrop [2 ]
Araujo, Mario Cesar Ugulino [1 ]
Silva, Edvan Cirino [1 ]
Jose, Gledson Emidio [1 ]
Soares, Sofacles Figueredo Carreiro [1 ]
Paiva, Henrique Mohallem [3 ]
机构
[1] Univ Fed Paraiba, Dept Quim, BR-58051970 Joao Pessoa, Paraiba, Brazil
[2] Inst Technol & Aeronaut, Div Engn Eletron, BR-12228900 Sao Jose Dos Campos, SP, Brazil
[3] Empresa Brasileira Aeronaut EMBRAER, Flight Control Syst, BR-12227901 Sao Jose Dos Campos, SP, Brazil
关键词
multiple linear regression; variable selection; successive projections algorithm; cross-validation; near-infrared spectrometry;
D O I
10.1590/S0103-50532007000800021
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This work compares the use of a separate validation set and leave-one-out cross-validation to guide the selection of variables in the Successive Projections Algorithm (SPA) for multivariate calibration. Two case studies involving diesel and corn analysis by NIR spectrometry are presented. A graphical interface for SPA is available at www.ele.ita.br/similar to kawakami/spa/.
引用
收藏
页码:1580 / 1584
页数:5
相关论文
共 10 条
  • [1] [Anonymous], 1998, Chemometrics: A Practical Guide
  • [2] The successive projections algorithm for variable selection in spectroscopic multicomponent analysis
    Araújo, MCU
    Saldanha, TCB
    Galvao, RKH
    Yoneyama, T
    Chame, HC
    Visani, V
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2001, 57 (02) : 65 - 73
  • [3] Determination of total sulfur in diesel fuel employing NIR spectroscopy and multivariate calibration
    Breitkreitz, MC
    Raimundo, IM
    Rohwedder, JJR
    Pasquini, C
    Dantas, HA
    José, GE
    Araújo, MCU
    [J]. ANALYST, 2003, 128 (09) : 1204 - 1207
  • [4] Simultaneous spectrometric determination of Cu2+, Mn2+ and Zn2+ in polivitaminic/polimineral drug using SPA and GA algorithms for variable selection
    Dantas, HA
    de Souza, ESON
    Visani, V
    de Barros, SRRC
    Saldanha, TCB
    Araújo, MCU
    Galvao, RKH
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2005, 16 (01) : 58 - 61
  • [5] A strategy for selecting calibration samples for multivariate modelling
    Dantas, HA
    Galvao, RKH
    Araújo, MCU
    da Silva, EC
    Saldanha, TCB
    José, GE
    Pasquini, C
    Raimundo, IM
    Rohwedder, JJR
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2004, 72 (01) : 83 - 91
  • [6] Galvao RKH, 2001, ANAL CHIM ACTA, V443, P107
  • [7] A method for calibration and validation subset partitioning
    Galvao, RKH
    Araujo, MCU
    José, GE
    Pontes, MJC
    Silva, EC
    Saldanha, TCB
    [J]. TALANTA, 2005, 67 (04) : 736 - 740
  • [8] GALVAO RKH, UNPUB CHEMOM INTELL
  • [9] Robust modeling for multivariate calibration transfer by the successive projections algorithm
    Honorato, FA
    Galvao, RKH
    Pimentel, MF
    Neto, BD
    Araújo, MCU
    de Carvalho, FR
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2005, 76 (01) : 65 - 72
  • [10] KANDUC KR, 2003, CHEMOM INTELL LAB SY, V65, P221